Specifications

Started Manual Castle Care-Tech Ltd
5·00 Page 47
SYSTEM DIAGNOSTIC
FACILITIES
The system diagnostics are
available for all parts of the
system, including any remote
power supplies fitted.
The diagnostic resolution is:
VOLTS: 0·1
CURRENT: 0·01A
System voltage and current
at End Station and at each
individual power supply.
System voltage – at each
Keypad / Tag Reader
Battery condition and charge
current – at End Station or any
remote power supply (under
development).
Display inputs – current status
of all inputs connected to a
single system component,
displayed in real time
iD Diagnostics
Slow scan, line
current, biscuit diagnostic current
– at End Station and each ZEM.
Calibration – permits calibration
of End Station PSU and iD output
voltages, using a calibrated
meter.
With display showing
DIAGNOSTICS?
Press YES
View PSUs?
Press YES
End Station PSU
13.75v 0.22A
Display shows diagnostic
readings for End Station
power supply in
q
uiescen
t
state
Press
A
to display alarm
current,
0
to return.
On completion, press YES
ZEM PSU [0]
13.65v 0.150A
Use YES / NO keys to select
other power supplies, etc.
Press NO
View Inputs?
Press YES
EndStation Inputs?
Press YES
cccOOccOccOccOc
OOcccFFFFFFFFFF
Display shows status of End
Station iD inputs (1
30) in real
time, displaying the following
codes:
c: input in normal * state
0: input in active state
F: input in Tamper state
T: iD input in
Twin Device
state
* -
‘normal’ state of PTS and
SHUNT inputs is OPEN, ‘active’
state is closed.
Note a corresponding display
is provided for EoL inputs.
Press YES
Zone status [01]
14mA 14mA
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 48 Software
Readings for iD biscuit 1 show
diagnostic
current, and
switch
current respectively
for that biscuit.
OR:
Input status [01]
2K2 DM
Readings for EoL input 1 show
the circuit resistance and
circuit status
CC: Closed Circuit
OC: Open Circuit
DF: Detector Fault
DM: Detector Mask
DT: Detector Tamper
Press YES
Slow Scan?
(Systems with iD in use only)
Press YES
Slow scan
Is in progress . .
System switches to iD slow
scan mode, so that actual
mid
scanning voltages on the
End Station iD line can be
measured (ideally, should be
6.50v).
Press YES
EndStation Inputs?
Press NO
ZEM Inputs?
Repeat above diagnostic steps
for zones wired to each input
Expander, Keypad or Tag
Reader
Press YES
DIAGNOSTICS?
Press NO
Moves to next menu item