Specifications

Castle Care-Tech Ltd
Page 1
Euro MERiDIAN ‘G’ Range
"GETTING STARTED" MANUAL
This manual provides the basic information required to install and
program a Euro-MERiDIAN G2/G3 system. Additional information for
upgrading with MSX Card to MSX-44, 134 or 256 is included in
supplementary instructions provided with the MSX Card (see below).
CONTENTS
Contents Page
1 Introduction 2
2
Specifications
3
3
End Station Terminal Layout
4
4
Installation Guidance
5
5
Wiring Specifications
13
6
Installing End Station and Keypads
16
7
Wiring Detectors
10
8
Wiring Outputs
20
ATE and Communicator Outputs
23
9
The Keypad Display
25
10
Powering Up and Addressing Keypads
26
11
General Programming Principles
27
12
Programming the System
30
13
Test & Diagnostic Features
49
14
System Logs
53
Appendix
Summary of Principal Programming Options
54
INDEX
55
Additional, and more detailed, information is available in the full "Engineering Manual"
Separate Technical Notes are available when using:
Access Control / Guard Tour Systems / External Set Unset Readers
DigiModem (including ARC digicom signalling, Downloading, and SMS text messaging)
iD
Technology
Output Modules / STU Output Modules
Expansion with MSX Cards
Wards and Shunt Zones
Zone Expansion
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 2 Software
1. INTRODUCTION
The
Euro
-
MERiDIAN is designed and
manufactured to our ISO9001
approved quality system to offer a
choice of options to suit most
security applications.
All systems can be controlled using
PIN Codes, proximity tags or by key-
(or other) switches.
The system COM9600 DigiModem
provides for Remote Signalling,
Downloading and/or SMS text
messaging.
EN50131
Euro
-MERiDIAN is suitable for
installation in systems complying
with PD6662:2004 specified as follows
(BSIA Form 171):
Product Security
Grade
Environment
Class
G2 Endstations 1 and 2 1 and 2
G3-MSX cards 1 to 3 1 and 2
G3 Plus 1 to 3 1 and 2
All power supplies conform to
EN.50131
-
6 (BSIA Form 180)
DD243:2004
The Euro-MERiDIAN ‘G’ range is fully
compliant with the requirements of
DD243:2004. All options are
supported EXCEPT:
Zeroing of 'Confirm Timer' if first zone
to alarm retriggers (A.3.1).
We have a booklet available outlining
how to install to DD243:2004
specifications, request TN-DD243
from our sales office.
Compliance Statement:
The
Euro
-
MERiDIAN range complies
with the requirements of the
European EMC Directive (89/336/EC),
the Low Voltage Directive (72/23/EC
and 93/68/EC) & from (1/1/2006) the
“Reduction of Hazardous Substances
Directive (2002/95/EC).
Appropriate components
also comply with the
requirements of the R&TTE Directive
(1995/5/EC).
It is essential that equipment and wiring
be installed to avoid being affected by
potential sources of interference.
WARRANTY
Castle Care
-
Tech Ltd will repair or
replace, at our discretion, any
product developing a fault within 2
years, free of charge. Products for
repair should be returned to the
factory, suitably packed to prevent
damage (including damage from
electrostatic discharges),
and be
accompanied by full details of the
fault, and the full return address
.
If the failure was caused by
operating the system outside of its
specification, by physical damage, or
by unauthorised modifications, we
reserve the right to raise an
appropriate repair charge.