User Manual For use with end station 28, MSX 44 MSX 76, MSX 280 software: Version 6.
You’ve Made the Right Choice Contents Introduction Using Euro-MERiDIAN with Code or Tag Intelligent Setting When Problems Arise Setting Individual Areas Chime Facility Omitting Zones Keypad Hold Up/Personal Attack Manager Menu Omitting 24 hr Zones Changing Date & Time Change/Add Codes or Tags Review History Log SMS Phonebook Walk Testing Detectors Testing your Sounder SMS Messaging System Dial Out Menu Allow Engineer Menu Block Remote Set Perform Anti-Code Reset Service & Codeholder Records SMS Disclaimer
You’ve Made the Right Choice Using your Euro-MERiDIAN Alarm System just couldn’t be easier! This is the Keypad from where you control your Alarm System* Note: For your security, the keypad becomes disabled for 90 seconds after 30 incorrect key-presses, or after 6 attempts to present invalid tags. It will subsequently be disabled again after 7 further incorrect key-presses or after another invalid tag is presented. Once a correct code or tag has been registered, the keypad is returned to normal operation.
The Euro Keypad MAINS FAIL The display gives you any important messages. It will alert you if you need to call your alarm installation engineer. The 10 digit numeric keypad is where you use your PIN code. Euro 1 Time: 15:02 The A B C D keys help simplify use, and will illuminate to highlight your choice of security cover, or flash if there is a problem. This is where you present your Tag.
Warning Indications All setting points (Keypads or Tag Readers) have lamps to clearly indicate what is happening. Alert Alarm Tamper Fault Unset The ‘Alert’ lamp will flash if there is information available to you. Enter your code to see the information. After a code has been entered, one of the following lamps will light: Alarm, tamper or fault. The relevant detail of the problem will be shown on the display.
Using Tags Euro-MERiDIAN’s High Security Proximity Tag (or Card) will set or unset your Alarm system with the minimum of fuss or complexity. The Tag contains NO batteries and is completely maintenance free. Just touch the Tag to the fascia below the logo to use. The Keypad will acknowledge the TAG.
Security Checks Before you set your system: You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors.
Leaving the Building Euro 1 Time: 15:02 If you are leaving the building, go to Keypad and key in your PIN code, or present your Tag. Exit tone Starts The appropriate area (ABCD) keys will illuminate. (If flexi-set is enabled you will be able to choose which areas you set, see page 19) Leave by agreed Exit Route SETTING [009] OFFICE If your exit is timed, you will see the above screen. If you use a Push-toSet button, or finaldoor-set, you will see the screen below.
Faults when you Switch On If when you key in your PIN code (or present your Tag) a warning tone sounds and the fault lamp comes on, the keypad display will show the nature of the problem. UNABLE TO SET BACK DOOR An appropriate A B C D key will flash to indicate within which area the fault exists. The tone will cease after about 10 seconds. Press the NO key The system will remain unset, so you can resolve the problem. For example, you may have left a door open, if so, close the door.
Faults when Leaving the Building If when you have closed the final exit door (and pushed the ‘Push to Set’ button if fitted), the exit tone continues to sound an interrupted tone… “beep – beep – beep – “ You have probably left a protected door on the exit route open. Return to the keypad and note the message on the display. EXIT VIA HALLWAY Stop the setting procedure with your PIN code, or Tag. Close the open door Now commence the setting procedure again (see page 7).
Entering the Building To enter the building you must use the agreed entry route and go straight to the keypad. ENTRY TIME [020] Entry tone will be sounding “beep – beep – beep –“ ENTRY [010] TIME ** Key in your PIN code, or present your Tag. Entry tone will cease To indicate that the system has unset, the unset lamp will illuminate for five seconds.
Using an External Proximity Reader Setting the Euro One with the Proximity Reader Action Visual Sequence Present a valid tag to the reader and then remove it. The GREEN LED will come on Present the same tag to the reader, and then remove it. The exit time will start on the control panel.
Part Setting the System Intelligent Set (if programmed) If you wish to set Euro-MERiDIAN and stay in the building (eg set the alarm at night), the EuroMERiDIAN’s intelligent operating system will realise which level of security you require and will set only part of the system. You will NOT need to press a Push-to-Set button if you set only part of a system. If intelligent set is not installed on your system, you may part set the system as described on Pages 18-19.
Using an External Proximity Reader Intelligent Set To Part Set Euro-MERiDIAN go to the keypad and enter your PIN code or present your Tag. The appropriate A B C D keys will illuminate Exit tone will start Leave the protected area and retire to the un-protected area (eg upstairs). Euro-MERiDIAN will detect you have gone upstairs and set the appropriate areas accordingly. After a preset time the exit tone will cease.
Using an External Proximity Reader When Problems Arise, Just Key in your PIN Code or present your Page 14
Silencing Alarms If an Alarm tone sounds, the Alert lamp will flash: Just key in your PIN code or Present your Tag. The Alarm will stop sounding Alarm Silenced Low Volts The display problem. will indicate the Press the ‘YES’ Key Call Engineer Low Volts Euro-MERiDIAN will advise you on any action that is needed. If the ‘Alert’ LED indication remains lit, there is additional information available. Enter your PIN or present your Tag to view.
Engineer Reset Quote G19867 Anti-Code Needed When an alarm has been cancelled and the Police have been notified by the Alarm Receiving Centre, you will see the following screen when you try to use the system. It is usually necessary for an engineer from your installation company to check the installation and reset the system for further use. But if you have caused the alarm in error your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present.
Automatic Inhibit Euro-MERiDIAN is designed to automatically disable certain functionality. The factory default settings are as shown below: Intruder Alarm Signal Tamper Alarm Signal Keypad After 3* unconfirmed alarms in the same area or 1 confirmed alarm. After 3* unconfirmed alarms in the same area or 1 confirmed alarm. After 30 keypresses without entering a valid code, keys are disabled for 90 seconds. After reinstatement, this will be repeated after each 7 keypresses until a valid code is entered.
The A B C D Keys Euro 1 Time:15:20 Sometimes your security needs will be a little more complex and you will need to use the A B C D keys. Your Installer can also give names to all four of the A B C D areas, so that you can easily identify them. Euro 1 Time:15:21 SETTING ALL AREAS For example: A=Reception B=Warehouse C=Office D=Storeroom or All Set Bedtime Set Cat in Lounge Dog in Study In addition, names can be given to the whole system ‘ALL AREAS’ These will be displayed when setting the system.
Codes with Flexi-Set SET AREAS [ABCD] For greater flexibility in setting parts of your system, you can make a choice at the keypad. Key in your PIN code or present your Tag. If you do not wish to set all the areas assigned to your code/Tag, simply select the areas you wish to Set by pressing the relevant A B C D key(s). To change your mind, press the relevant A B C D key(s) again.
Flexi-UnSet Euro 1 Time:15:25 When Euro-MERiDIAN is already set and you wish to unset: Key in your PIN code or present your Tag. If entry timer has started: All areas for which the Tag or PIN is valid will be Unset. Any areas set for which the code is not valid will remain set, eg if A and B are set: If an ‘A’ Tag is presented, only area A will be unset. If an ‘A B’ Tag is presented, both A & B will be unset. An ‘A B C’ Tag will unset A & B, leaving C unset.
Flexi-UnSet If your codes have been set up with Flexi-Unset enabled, you will always have a choice of what areas you would like to set or unset, regardless of whether the entry timer is running or not – providing you have a code valid for the relevant areas. This function can only be enabled by your alarm installing company, and will not be permitted if your system is designed to comply with clause 6.4.5 of DD243:2004.
The Chime Facility The ‘C’ key can be used to select the ‘chime’ facility while the system is Unset. For example, you may wish to be alerted if someone enters through a particular door during the day. Simply press the ‘C’ key. Euro 1 Time: 15:31 Euro 1 Time: 15:32 The display will show a ‘C’ c Now if the door opens you will be alerted by the ‘chime’ tone. To cancel the ‘Chime’ simply press ‘C’ again. function, Note: This is only operative on detectors programmed for this purpose.
Deliberately omitting an Input when leaving the Building In a domestic setting you may wish to ignore a window you have deliberately left open in the summer time. There may be another fault on the system which you want to ignore when you set the system. Enter your PIN code or present your Tag. The display will ask if you wish to set with the fault. Set with Fault? Bedroom Window To omit the fault, Press ‘YES’ (or ‘NO’ if you don’t!) The system will then set as normal.
Deliberately omitting an Input when leaving the Building OMIT INPUT? At some time you may wish to isolate a detector if a room is occupied. Enter your PIN code or Tag. While the exit tone is sounding press the ‘YES’ key. When the ‘OMIT INPUT’ menu is displayed: Key in the number of the zone you wish to omit and press ‘YES’. (Always use a leading zero, eg 02 is input 2. On larger systems 002 is input 2) If it has been accepted it will be displayed on the screen.
Keypad Hold-Up Euro 1 Time:15:40 If you ever need to summon personal assistance in an emergency, Euro-MERiDIAN allows you to do so. Simply press the ‘1’ and ‘7’ keys at the same time. To reset: Enter you PIN code or present your Tag. Note ghgfiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii This facility is only available if it has been enabled by your alarm installer.
Manager Menu To enter Manager Menu, press ‘D’ and then key in your code or present your Tag. The screen will display any relevant information; simply press ‘No’ to move into Manager Menu. We recommend that your system is fully disarmed to use Manager Menu functions.
Manager Menu Euro 1 Time: 15:45 The manager menu is accessed by pressing ‘D’ and then keying in your Manager PIN code.
Manager Menu Press ‘D’ and key in your Manager PIN code or user code. SET DATE & TIME? The first Menu choice asks you if you wish to ‘Set Date & Time?’ If you wish to enter the menu, press ‘YES’. But if you wish to move on to other Manager Menu items press ‘NO’. The USER MENU is similar to the manager menu, with some choices unavailable (see page 27).
Set Date and Time SET DATE & TIME? Press ‘NO’ to move to next menu. Press ‘YES’ (Press ‘NO’ to move to the next menu) YEAR MONTH (00-99) [06] (1-12) [08] Enter Year (eg 06=2006) Press ‘YES’ Enter Month Press ‘YES’ DAY (1-31) [12] Enter Day Press ‘YES’ HOURS (00-23) [13] Enter Hours (24 hour clock) Press ‘YES’ MINUTES (0-59) [45] Enter Minutes Press ‘YES’ To go to the next menu, press ‘NO’ again.
Omit Inputs Omit Inputs[--] Some of your doors may rarely be used. Opening them, even with Euro-MERiDIAN Unset, may be designed to cause an alarm. If you need to open these doors you can omit them from the system as shown below. (Only zones of ‘tamper’ and ‘day alarm’ type can be omitted this way, as set up by your alarm installing company). Omit Inputs[06] FIRE DOORS Enter the input number you wish to omit. Press ‘YES’ Omit Inputs[--] To reinstate inputs simply key in the number again.
Changing or Adding PIN Codes or Tags A record should be kept as shown on Page 51 CHANGE CODES? Press ‘YES’ (Press ‘NO’ to move to the next Menu) Change User Codes? Press ‘YES’ (Press ‘NO’ to programme the Master Manager Code) Turn to the next page to continue to programme user codes. Change Master Manager Code? Press ‘YES’ (Press ‘NO’ to move to the next menu) The Master Manager Code can only be changed by the Master Manager. Turn to the next page to continue to programme the Master Manager Code.
Changing or Adding PIN Codes or Tags USER NUMBER [02] Euro-MERiDIAN identifies each user by a different ‘User Number’. Eg ‘John’ would be user 01 – ‘Jane’ would be user 02 etc. Now key in the ‘User Number’ whose PIN code/Tag you wish to add or change. Press ‘YES’ ENTER USER CODE [****] Key in the new 4,5 or 6 digit PIN code you require or present the new Tag. To delete a code or Tag press ‘C’.
Changing or Adding PIN Codes or Tags User Type (User) [0] Choose the level of authority the code-holder is allowed. User – cannot access Manager Menu. Manager – can use Manager Menu. (Use ‘B & D’ keys to make your choice). Press ‘YES’ User Areas [A ] Using the A B C D keys, choose the areas you wish to be controlled by the code-holder.
Changing or Adding PIN Codes or Tags Flexi Set Yes Flexi Set No [1] [0] Flexi Set Yes [1] Flexi-Set gives you the opportunity to choose the areas you require to set when you use your PIN code or Tag. If you do not choose Flexi-Set your Code/Tag will simply set the areas assigned without offering you the opportunity to choose. For simplicity of use, choose ‘NO’ (Make your choice with the ‘B’ and ‘D’ keys) Press ‘YES’ Systems installed to Grade 2 requirements must have 10,000 code differs.
Changing or Adding PIN Codes or Tags Using the numeric keys, you can enter a user name, similar to typing a text message on a mobile phone. Use ‘0’ key for space.
Review History Log REVIEW LOG? Press ‘YES’ (Press ‘NO’ to move to the next menu) Panel Log? Press ‘YES’ To advance through the logs: Date & Time Press ‘D’ For added information: Press ‘C’ To move events: backward to previous Press ‘B’ To stop review: Press ‘NO’ To move to the next menu, press ‘NO’ again.
Review History Log If Access Control Facility is in use, a separate log is available dedicated to events using this function. Follow the same procedure as described on page 36, but press ‘NO’ to choose between ‘PANEL LOG’ and ‘ACCESS LOG’. Access Control is available if your panel is fitted with an MSX-44, MSX-76 or MSX-280 card.
SMS Phone Book Press ‘YES’ PHONEBOOK? (Press ‘NO’ to move to the next Menu) SMS Numbers [1] Use the ‘D’ key to scroll to which SMS telephone number you wish to change (1-4). Press ‘YES’ Mobile No. 07 951_ Using the numeric keys, type in the new telephone number (do not leave any spaces). You can move the cursor back with the ‘B’ key and forward with the ‘D’ key. Use the ‘C’ key to delete a character.
Walk Test WALK TEST? Press ‘YES’ (Press ‘NO’ to move to the next Menu) Choose the area(s) you wish to test by pressing the appropriate ABCD keys. Walk Test Zone Front Door Press ‘YES’ All detectors waiting to be tested will scroll in the display. Walk around the building trigger all of the detectors. and The system will ‘chime’ each time a detector responds. Walk Test Completed WALK TEST? When all detectors have been activated and are working, the display will show ‘Walk Test Completed’.
Testing your Sounders WALK TEST? Press ‘YES’ (Press ‘NO’ to move to the next Menu) Testing Siren Press ‘YES’ Siren will sound, Strobe will flash SIREN TEST? Press ‘NO’ to move to next menu.
Test CHC Communications Your system may have been configured to send messages to a mobile telephone. If so, the system will call the appropriate messaging bureau and forward the message to your mobile telephone whenever an even occurs that is important to you. Message calls are charged at the normal network rate current at the time of the call.
Test CHC Communications It is recommended that this test is only undertaken under the supervision of your alarm installation engineer. TEST CHC COMMUNICATIONS? Press ‘NO’ to move to the next menu Press Y if using PABX or N if not If your alarm panel is connected to an internal telephone network (PABX system) which requires a ‘9’ for an outside line, press ‘YES’, otherwise press ‘NO’.
Dial Out Menu DIAL OUT MENU? Your alarm system may be configured so that you can control the system via a PC. If you wish to continue… Press ‘YES’ (Press ‘NO’ to move to the next menu) Select PC to dial [1] Select Operation Data to PC [4] Select Operation Diagnostics [5] Calling Remote PC Use the ‘D’ key to select the required PC from the list (1-4) and Press ‘Yes’.
Allow Engineer Menu ALLOW ENGINEER MENU? When your alarm installation engineer comes to your premises for a maintenance visit or to correct a fault after an alarm he will require access to the programming of the system. Press ‘YES’ Allow Engr Menu? Yes [1] Use ‘B & D’ keys to make your choice. Press ‘YES’ After the engineer has finished on site, you may return this setting to ‘NO’.
Block Remote Set BLOCK REMOTE SET? Your alarm system may be configured so that your alarm installation company or company manager can set or unset the system remotely via PC. Should you wish to block this access you can do so through this menu. Press ‘YES’ Block Remote Set No [0] Make your choice with the ‘B’ and ‘D’ keys. This option is not available on the Euro ONE 28.
Block UDL If you wish that your alarm company can only dial into your system with their PC whilst their engineer is on site, this can be set up through the ‘Block UDL’ menu.
Anti-Code Restore Note, this item will ONLY appear if engineer restore is required and will appear first in the user menu Your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present. ENTER ANTICODE? Press ‘YES’ Eng Restore Required G15234 Enter your Code [ ] You will be required to quote this 6-digit code by telephone (advise them that the system is a Castle Euro-MERiDIAN).
User Programmable Functions Persons holding Manager codes to Euro-MERiDIAN have access to the following programming options: Set Date & Time (page 28) Change User Codes (page 31) Change Mobile Telephone Numbers (page 38) Allow Engineer Access (page 44) Inhibit (omit) Zones from the system (page 29) Allow Remote Set (page 45) To do so, press ‘D’ and enter your Manager PIN code or Tag.
Menu Exit EXIT MANAGER MENU? To exit from Manager Menu and return to normal mode. Press ‘YES’ If you wish to select any of the Manager Menu items again press the ‘NO’ key until your choice is displayed (see page 32).
Service Information We are sure that you will be delighted with your Euro-MERiDIAN Alarm installation. For your personal reference here is a record of the relevant service information.
User Codes Warning: This information should be removed from the manual and stored in a secure location. Photocopy this page if you have more users. No.
Disclaimer Euro-MERiDIAN includes the facility to send electronic signals to an Alarm Receiving Centre (ARC), and also to send SMS text messages to mobile telephones. Alarm, etc. signals may be transmitted via a PSTN link, using a variety of formats, to suitable receiving equipment located at the premises of an independently operated Alarm Receiving Centre.
No Areas A B Descriptions C D 0 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Page 53
No Areas A B Descriptions C D 0 1 2 3 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Page 54
Page 55
Page 56