Specifications
Castle Care-Tech Ltd. Engineering
Page 13 - 12 Chapter 13
PROGRAMMING STEPS
With the display showing
CHANGE ZONES?
Press YES
Zone Number
[01]
Press YES
Zone Type
Isolated [00]
EITHER use
D
to scroll to
required setting OR key in
zone type number from
table above – eg 07
Zone Type
Final Exit [07]
Press YES
Zone Areas
[ABCD]
Use keys to select the
security patterns required,
eg press
AB
Zone Areas
[AB ]
Whilst programming this
step, the relevant keypad
Area (A,B,C,D) keys will
illuminate when that
pattern is selected.
Press YES
Zone Areas
Any [0]
Area Setting systems only:
Use
D
to select
‘
Any [0]
’
or
‘
All [1]
’
as required
Press YES
Zone Attributes?
Press YES
Chime
No [0]
Use
D
to select No [0],
Single [1] or Follow [2]
Press YES
Omittable
No [0]
Continue to select zone
attribute options as
required, until
Zone Name?
Press YES
Enter Zone Name
Z
one 01
Enter text to identify zone,
as described on page 13
-
3.
Press YES
Zone Number
[01]
EITHER key in next zone
number to programme, or
NO to exit function
CHANGE ZONES?
Press NO
Moves to next menu item
NOTES:
After programming the zone, exit
engineering for this to take
effect before walk testing, etc.
See Chapter 16 for information
relevant to ‘Shunt’ zones.