Specifications

Castle Care-Tech Ltd. Engineering
Page 13 - 10 Chapter 13
Types 13, 15-17 are NOT
available on Euro-22/28.
Newly programmed zones will
NOT be live, and therefore
cannot be walk tested, until
after exiting from Engineer
mode.
An ‘Entry Route’ zone trigger will
be stored for 2 seconds before
an alarm is activated. If a Final
Exit zone is triggered within this
time, the system will select entry
time, rather than an alarm.
Part set refers to levels B, C
or D on a ‘Level Setting’ system,
or to any combination other than
“all available areas” on an ‘Area
Setting’ system.
Use of Fire Zones
Any fire detectors used MUST
be selected and sited to meet
the requirements of BS.5839.
Euro-MERiDIAN is NOT suitable
for use on sites requiring a fire
alarm system installed to full
BS.5839 specifications, but may
be used to monitor an alarm
signal from such a fire alarm
panel in order to trigger a
communicating device.
SECURITY PATTERNS
There are two setting patterns
available on the Euro-MERiDIAN
range. Euro-44+ and above
have choice (see page 13-36),
others are fixed as 'Level
Setting:'
LEVEL SETTING
The user has a choice of setting
A or B or C or D; each set level
will provide a different pattern
of security coverage. Each zone
therefore will need to be
allocated into the required
patterns (or levels).
For example, the front door
may need to be active in all
setting scenarios, and would
therefore be programmed as
[ABCD]. On the other hand, the
master bedroom may only
need to be active if ALL the
system is set, and would
therefore be assigned [A ].
The kitchen may need to be
active at all times, except when
the dog is left at home (D set)
and at night ('B' set) and would
be programmed [A C ].
AREA SETTING (Euro-44+ and
above)
The user has the option of
setting any combination of the
areas, and of ‘adding to’ or
‘subtracting from’ those areas
set at any time.
Normally zones are allocated to
a single area. Alternatively, they
may be programmed to more
than one area, in which case
the choice of ‘ANY’ (zones live if
any of programmed areas is
set) or ‘ALL’ (zones live only if all
of programmed areas are set)
will apply for those zones.
For full details refer page 7-2.
NOTE: "UNSET" zones will
ALWAYS use the "ANY" response.