Specifications

Castle Care-Tech Ltd. Engineering
Page 13 - 2 Chapter 13
This gives access to a number of
sub menus, each of which
enables a system function, or
group of associated functions,
to be programmed.
To use the engineer menu at a
different keypad, simply press
'B' at the alternative keypad.
EXIT ENGINEER MENU
On completion of programming
or use of test/diagnostic
functions, the system can be
returned to normal mode by:
EXIT ENGINEER
MENU?
Press YES or
A
Please Wait
Saving NVM data
Please Wait
Checking System
The system will check the current
status of zones that would trigger
an alarm if open, as well as certain
programmed parameters.
If the display shows a fault message,
return to engineer menu and
correct the problem before again
attempting to exit (see below).
Euro-MERiDIAN
Time: 17:24
OR:
With the display showing any MAIN
menu item (ie shown in CAPITALS),
press
A
. The sequence followed will
then be as above.
NOTE: system voltage readings
should NOT be taken immediately
after exit - see page 10-4.
Fault Indications
Should one of the following
messages be displayed on
attempting to leave the
engineer menu, correct the
fault or adjust the programming
before making a further
attempt to exit:
Check Failed
Zone name
This indicates that a 24-hour
Tamper or similar zone is in fault
condition, or a tamper fault
exists on the zone identified, so
that an alarm would be
generated if the system
returned to normal mode.
Multiple faults will scroll.
Error zone areas
not accessible
Zones have been programmed
to an area(s) for which no
Setting Point is valid to unset
eg it would be impossible to
reset after a tamper alarm on
that zone.
Programming must be adjusted
before again attempting to exit.
Error some areas
cannot be unset
Setting Points have been
programmed in such a way that
it is possible to set an area that
cannot be unset from any
Setting Point.
Programming must be adjusted
before again attempting to exit.