Specifications

Manual Euro-MERiDIAN
Chapter 9 Page 9 - 7
b) Means of Completion of
Setting
DD243:2002 permits a variety of
methods. These should be
considered carefully and
compared to the permitted
'means of unsetting' to select
the most suitable combination.
For details of zone
programming, refer page 13-6;
Timers page 13-17; Exit modes
page 13-19.
ALL permitted options can be
used with Euro-MERiDIAN.
(i) Key Operated Shunt Lock
fitted to final exit door:
Wire suitable lock to zone
programmed as "Final exit."
Programme exit mode as "Final
Door." Door contact fitted to
door should be programmed as
"Entry Route" zone type.
(ii) Push Button switch
mounted outside the
protected premises:
Wire suitable button as zone
programmed as "PTS" and
programme exit mode as "PTS"
(iii) Protective switch (ie door
contact) fitted to the final exit
door:
Wire the door contact to a
zone programmed as "Final
Exit" and programme exit
mode as "Final Door."
(iv) Use of Portable ACE
This requires the use of a tag
(or equivalent) whilst OUTSIDE
the premises to perform the
'PTS' operation. A suitable
device may be wired as a 'PTS'
zone, as option (ii).
There is currently no suitable
device within the Euro-MERiDIAN
range.
(v) In conjunction with ARC:
This may be carried out using
'downloading' features of the
system by an ARC running
'Euro-InSite' software.
(vi) Other compliant methods if
installed to requirements of
EN50131:
Possible methods include use
of key operated or electronic
lock wired to system as
'Keyswitch' or 'Blockschloss'
zone (see page 5-9).
c) Means of Unsetting
A variety of methods are
permitted, which may be
achieved as under:
(i) Unlocking initial entry door
unsets the IAS:
Lock contacts should be wired
to "Unset" zone.
Note this cannot be combined with
"completion of setting by key
operated shunt lock on final exit
door" using the same switch
contacts.