Specifications

Manual Euro-MERiDIAN
Chapter 18 Page 18 - 5
Relay capable of switching up
to 50 volts, up to 10 amps. This
may be used to switch the
internal supply, or any suitable
external supply, including AC
voltages.
Alarm Output
Relay capable of switching up
to 50 volts, up to 10 amps. This
may be used to switch the
internal supply, or any suitable
external supply, including AC
voltages.
Request to Exit Button
and Door Monitoring
Connections
If an electromagnetic lock or
solenoid bolt is used, a RTE
device (exit button) is required
to permit exit. This is activated
when the normally open push
button is momentarily closed.
The Door Monitoring facility
may use a switch contact on a
monitored door release, but a
separate security door contact
is recommended.
NOTE: Each Door Station has
these connections available.
Automatic Release from
an Alarm Output
A Fire Alarm Auxiliary relay
output may be wired in place
of the Exit Button shown in the
diagram above.
Alternatively, any appropriate
output on the Euro-MERiDIAN
system may be used to drive 0v
directly into terminal U12 to
achieve the same functionality.