Specifications

Castle Care-Tech Ltd. Engineering
Page 16 - 6 Chapter 16
Programming the Shunt
Zone and List.
With the display showing
CHANGE ZONES?
Press YES
Zone Number
[01]
Select zone number required,
and press YES
Zone Type
Isolated [00]
Select zone type 18 and
Press YES
Zone Type
Shunt [18]
Press YES
Shunt List _ _
None
Use number keys, followed by
YES
to select the zones that
are to be within the shunt list.
These will scroll continuously to
identify those selected
-
eg to
select zone 7, key
07
(or
007
) and
Press YES
Shunt List 07
Canteen Door
Zones to be entered onto a
Shunt List MUST already be
enabled in programming.
To delete a zone already present
in the list, simply enter the zone
number again
.
When the Shunt List is complete,
escape from the menu by
Pressing NO
Zone Name?
Press YES
Enter Zone Name
Z
one 01
Enter text, as described on
page 13-3
Zone Number
[01]
EITHER key in next zone
number to programme, or NO
to exit function
Press NO
CHANGE ZONES?
Press NO
Moves to next menu item