Specifications

Castle Care-Tech Ltd. Engineering
Page 13 - 36 Chapter 13
Option Function
2 Key
PA
Selects whether the
2
-
key
PA
function at the Keypads
is live, and if so, whether
signalled only, audible only,
or both.
If used, the
1
and
7
keys,
pressed simultaneously, will
generate a Duress alarm.
Digi
-
Reply
Permits selection of inputs
on
plug
-
on
or loom
connector to suit
STU
(inc.
Red Care Reset),
Digicom
(inc. Fail to Communicate),
Relay Interface monitoring
or
not used.
NOTE
: This option MUST be set to
'STU' or 'Digi' in order for Line Fault,
etc. Monitoring to function.
INVERT
STU O/Ps
(version
3·1)
Changes outputs at STU
pins, to trigger as
“POSITIVE REMOVED”
instead of the default
“Positive applied.”
Prevent
PIN
codes
(Version
3·1)
If selected, Manager codes
can ONLY program TAGs
NOT PIN codes.
(Engineers
can still programme PIN
codes for DURESS etc
purposes)
PROGRAMMING PROCEDURE:
With the display showing
SITE OPTIONS?
Press YES
Set Mains Fail?
Yes [1]
Use
D
to select
No [0]
or
Yes
[1]
Repeat for other options to:
2 Key PA
None [2]
Use
D
to select
None [2],
’‘
Silent
[0]
’‘
Noisy [1]
or
Both [3]
Note
:
None
Silent
Noisy
Both
=
=
=
=
No response
Digi (Duress) response ONLY
Audible response ONLY
Digi AND audible response
Press YES
Digi Reply
None [3]
Use
D
to select
STU [0],
’‘
Digi
[1]
or
Relay [2]
Press YES
SITE OPTIONS?
Press NO
Moves to next menu item