Specifications
Castle Care-Tech Ltd. Engineering
Page 13 - 26 Chapter 13
Repeat for other areas.
Press YES
Fire Starts at
Digi [3]
Repeat for FIRE alarms.
Press YES
Gas Starts at
Digi [3]
Repeat for Gas alarms.
Press YES
PA Starts at
Digi [3]
Repeat for PA alarms.
Press YES
Day Alarm Starts
Int Sounders [1]
Repeat for Day alarms.
The following steps are
available ONLY on AREA
SETTING systems:
Press YES
Start at
Digi [3]
Permits first level of response
upgrade. Identifies response
system will immediately
generate if any of the
additional area(s) are set, as
defined in next programming
step. May be set for 'Internal
Sounders' 'Sirens only' or 'Digi'
NOTE This upgrade will be
operative if
ANY
of the areas
selected here are set.
eg system may be
programmed for Area A alarm
response to start at keypad
bleepers and graduate to
'sirens only,' but to be
immediate 'sirens only' if area
B also set, etc.
Use
D
to select option
required
Press YES
if areas set
[ - - - -]
Use keys to select which
area(s) are required to be set
for upgrade level selected in
previous step to apply.
Press YES
Start at
Confirm [4]
if areas set
[- - - -]
Repeat above steps to
program second stage of
upgrade - eg to graduate to
'Confirmed' response if ALL
areas are set, etc.
Press YES
ALARM RESPONSE?
Press NO
Moves to next menu item