Specifications
Manual Euro-MERiDIAN
Chapter 13 Page 13 - 25
(xiii) ALARM RESPONSES
Silent 1
st
Alarm
This prevents all system sounders
from becoming live until an alarm
has been 'confirmed' - eg to
prevent noise interfering with
audio confirmation equipment.
Disable Confirmation on entry
Used with a suitable FX, Unset or
Keyswitch zone disables all
sequential confirmation operation
to satisfy certain options in DD243
(see page 9-7
Zones to confirm after entry
Accepts choice of 1 or 2 zones to
trigger after expiration of entry
time to qualify as 'sequentially
confirmed' alarm.
ONLY THE "2" SETTING
COMPLIES WITH DD243
:
2002
.
Each area alarm response
may
be programmed with the option
of
‘
graduated
’
functions, as can
‘
Day Alarm,
’‘
Fire,
’‘
Gas
’
and
‘
PA
’
alarms (note some alarm types are
ONLY available on Euro
-
44+ and
above). Graduation can be
between 'Keypads,' 'Internal
Sounders,' 'Sirens only,' 'Digi' and
'Confirm.'
The following options are
available for each:
Starts at
_ _ _ _
Insert level at
which alarm starts
Stops at
_ _ _ _
Insert level to
which alarm
graduates
The following additional options
are available on AREA SETTING
systems only:
Starts at
_ _ _ _
if area
_ _ _ _ set
Select higher
starting point valid if
additional
Starts at
Digi if
areas
_ _ _ _ set
Insert areas
required to be set
for response to be
upgraded to ‘digi’
(leave blank if
upgrade not
required)
When graduated function is
programmed, each step will apply
for 15 seconds before the next
graduated step.
PROGRAMMING PROCEDURE:
Note some alarm types are
available only on Euro-44+ and
above:
With the display showing
ALARM RESPONSE?
Press YES
Area A Starts at
Digi [3]
Use
D
to select from
‘
Keypads
[0]
’‘
Int Sounders [1]
’‘
Local [2]
’
and
‘
Digi [3]
’
eg
Press YES
Area A stops at
Confirm [4]
Use
D
to select from
‘
Keypads
[0]
’‘
Int Sounders [1]
’‘
Local [2]
’
‘
Digi [3]’ and 'Confirm [4]'
Press YES
Area B Starts at
Digi [3]