Specifications

Manual Euro-MERiDIAN
Chapter 13 Page 13 - 21
(xi) PROGRAMMING CODES
and TAGS
Codes may be 4-,5- or 6-digit,
or proximity Tags. Using a 5- or
6-digit code will automatically
block several possible 4-digit
codes that clash with it. It is
preferable to avoid mixing
different length codes on the
same system.
The areas valid for codes / tags
are programmed individually. A
Flexi-Set option is available to
permit selection of areas at the
time of setting and unsetting
where this is required.
CODE TYPES and NUMBERS
Product: User/Manager
Codes
Duress/Guard
Codes
Euro-10 12 10
Euro-12 12 10
Euro
-
22 20 10
Euro
-
28 20 10
Euro
-
44+ 100 20
Euro
-
134 230 20
Euro
-
256 500 20
Plus Master Manager and Engineer
codes
NOTES:
Manager and User codes can
ONLY be programmed through the
MANAGER menu.
Duress and Guard Codes can be
programmed ONLY through the
Engineer menu.
CODE CAPABILITIES
Type Functions
Set and Unset System USER
Default
1234
Also for Access
Control and Ward
Control functions
MANAGER Set and Unset System
Also access to
Manager menu
functions
Program
by
MANAGER
only
MASTER
MANAGER
Default
2222
Set and Unset System
Also access to
Manager menu
functions
(see box below)
Program
by
Manager
OR
Engineer
ENGINEER
Default
1111
Access to all
Engineering
functions, also
set/unset system for
test purposes.
DURESS Unset System,
generating silent
Duress
or
Hold Up
signal
GUARD
(Only on
Euro-
44+ and
above)
Unset system, but
only after an alarm,
provided alarm has
been active for a
minimum time
(programmable).
Also Set System
An output type is
available to signal
whenever this code
is used.
Program
by
ENGINEER
only.
The Master Manager and Engineer
Codes CANNOT be deleted.
From Software Version 3·1, the
MASTER MANAGER CODE will NOT set
or unset the system. It will solely give
access to the Manager Menu. NOTE:
during programming, it will appear to be
valid to “set” the system, but will NOT do
so.