Installation Guide

TROUBLESHOOTING
TROUBLESHOOTING
If it is believed in that the product has a fault, eliminate the fault as below. If
the product cannot work normally after that, please contact the local repair
center or reach us through our service hotline.
TECHNICAL SPECIFICATION
Fault
phenomenon
Cause
analysis
Solution
Water leakage
Loose hose
connector
Turn off the water supply switch and check
whether the connector between it (or the product)
and the hose is tightened.
Flushing failure
Abnormal
water supply
Check whether the water supply switch is on and
whether the filter is blocked.
Insufficient
flushing force
Too low water
supply
pressure
Please make sure the water supply pressure is
above 15PSI.
Insufficient
water in the
tank
Please make sure the interval between each twice
flushing is longer than 60s.
12
Item Description
Model
Flushing capacity 3.8Lpf(1.0gpf)
CD-W10V
0.1MPa ~ 0.86MPa (15PSI ~ 125PSI)
Applicable water
supply pressure
(static pressure)
4°C ~ 35°C (39.2°F ~ 95°F)
Water supply
temperature
4°C ~ 40°C (39.2°F ~ 104°F)
Ambient
temperature
Dimensions 26.9 x 15 x 19.3in (length x width x height)