User manual

SmartGuard CS Client/Server User Manual
7.2.1.16 Data Menu: Door Setting ->Global Door
As we know the SMARTGUARD CS software can support a maximum of 512 doors (
depends
on the controller type and sof ware version
). Of course, there will be some common setting
for some of these doors that we can be applied the setting at one time. Therefore, the
SMARTGUARD CS software has been designed to simplify the door setting operation by
grouping all the common setting into a single function. The common settings are
Anti-Pass
Back mode, Check Expiry Date in Door Accessibility Card Lock Out Function, Facility Code
Setting, Auto Pin Number
and
Auto Pin Number Time Zone.
t
,
To configure the Global Setting, the user is required to press “Modify” button, a list
parameters will be shown for the user to set-up.
Global Door Settin
g
- Anti-Pass Back
The Anti Pass Back feature is designed to ensure the user always transact a “In”
transaction at the door reader and followed by one ”Out” transaction, before he/she can
carry out another transaction. For instance, if a user swipe his/her card at door A to
grant access to a room then passed the card to another person to attempt at door A
again, the second entry will be denied by the door controller. The user is required to set
this field “On” to enable this option and “Off” will disable the option.
- Check Expiry Date In Door Accessibility
Setting on this mode will instruct the CASTLE controller to check the validity date of the
user card. A card with expiry door accessibility will unable to grant access at a door.
- Card Lock Out
The Card Lock Out function is mainly designed for higher security guarding condition,
where the CASTLE controller will lock out the user card if several invalid attempts at the
door reader take place. This includes 3 consecutive wrong PIN number access, 3
consecutive Anti Pass Back violation. The user should switch on this mode if he/she feel
that necessity of a higher security door access control.
Cass Technology Sdn Bhd 61