User manual

SmartGuard CS Client/Server User Manual
- Security
The security option works similarly to the Auto Lock Release Time Zone option. The main
different between these two is the
Security option is not manage by
time zone setting. A security off
action will allow a door to be freed
permanently until a reset is
triggered and the security on action
is the opposite.
- Card + Pin Mode
Setting off the card + pin mode will
disable the function even though
the time zone is still active.
- Pin Mode
Setting off the pin mode will disable
pin mode even though the time
zone is still active.
- Use common pin
This setting will used to set the
reader to use the Auto-Pin number
that set at the controller or use the
Local Auto-Pin number that set to
the specify door.
- Local PIN #1
4 digit of number are required to set the Local Pin 1 number. This is only can be used
when the Use Common Pin Mode is OFF.
Individual Door Settin
g
- Local PIN #1 TZ
Set the Time Zone for the Local Pin 1 so that Local Pin 1 can be used within the Time
Zone setting.
- Local PIN #2
4 digit of number are required to set the Local Pin 2 number. This is only can be used
when the Use Common Pin Mode is OFF.
- Local PIN #2 TZ
Set the Time Zone for the Local Pin 2 so that Local Pin 2 can be used within the Time
Zone setting.
- Emergency Mode
This is a safe guard method for the CASTLE system. The setting of this mode is to make
sure no down time happened at CASTLE door. In the event of communication error
between CASTLE door readers with the host controller, the door controller will react
immediately according to the emergency mode. The user can define 3 different type of
emergency mode, namely
Auto Pin
,
Lock Release
and
Facility Code Entry
.
Auto Pin setting will instruct the door controller to accept Emergency Pin no to grant
access.
Lock Release Mode will permanently release the door and ,
Cass Technology Sdn Bhd 59