Specifications
User Friendly.
Runs on Windows NT4 and above. (Well-known stable platform for critical W indows Application)
Controls Access Control, Alarm Monitoring , Guard Tour System and simple Time Attendance System,
under the same software.
Manages CASTLE-S/T Series Door Access Controllers,
CASTLE-SL Series Lift Access Controllers,
CASTLE-SP Series Car Park Access Controllers and
CASTLE-FEP-ALM Series Alarm Front End Processor.
Access Control Capacity
a. Use only RS485 - 2 wires to connect to each controllers.
b. Max. 2 buses of controllers.
c. Can control up to 2 buses of access controllers
(16 controllers per bus)
(1 bus = max. 128 doors, 2 bus = max. 256 doors depending on controller model configuration)
d. 5000 Card Holders.
e. 2500 Transactions Buf fer In First In First Out Basic.
f. 100 T ime Set.
g.100 Time Zones.
h.100 Door Accessibility.
Alarm Monitoring Capacity
a. Use only RS485 - 2 wires to connect to each controller.
b. Max. 2 buses of Alarm Panels (16 Alarm Panel per bus).
c. Can control up to 32 CASTLE Alarm Panel under the FEP.
d. Alarm Panels includes
i.CTA 16-16 Supervised input and 4 relay outputs card. (Supervised inputs are able to detect Fault, Alarm and Normal).
ii. CTA 32 - 32 Mimic Panel LED Driver card
iii. CG 16 - 16 Station Guard Tour Controller.
e. Max. 512 supervised Inputs.
f. Max.128 Relay Outputs (Can be triggered by event program or time zone or manual control)
g. Max. 100 tour routes can be configured.
h. 99 Event Programs.
i. 16 Guard Tour Station (Can be Card Swipe Station / Key Switch Station)
Software User Interface
a. User Friendly.
b. Dynamic Floor Plan Display.
i. Each device in the system is represented by icon.
ii. Icon will be flashed when the corresponding input device is in alarm.
iii. Dif ferent icon is used to represent the respective state of the device.
iv. When alarm occurs the floor plan systems will switch to the floor plan page containing the device.
v. Max. 100 floor plan can be configured.
vi. Max. 20 devices per floor plan.
vii. Floor plan can be configured right from the same software.
viii. Auto floor plan switching featured.
c.PC Buzzer Sounder when alarm triggers.
d.Comprehensive Report Generation.
e.Daily and Monthly Time Attendance Report Generation.
f. Menu Accessibility Control.
g.Can place own logo in the report print out.
h.Password protection system operator.
i.Photo can be included in the card holder database.
j.Automatic Transaction Uploading.
Uses RS485 Communication - Industrial Standard Communication Technology.
Client / Server Version available for Multi - W orkstation Working Environment and using MS-SQL Database.
Instruction message can be defined.
On-line help.
Castle Alarm Monitoring System (CAMS)
1) C TA 16 - 16 Supervised Inputs and
4 Relay Outputs Board
16 Supervised Inputs and 4 Relay Output Board.
Connect to the FEP (Front End Processor) using
only 2 wires (RS485).
LED indicator on board for easy troubleshooting.
Inputs are supervised for cut and bypassed.
Able to detect Alarm and Normal Conditions in 1
resistor termination mode.
Able to detect Cut, Bypassed, Alarm and Normal
Conditions in 2 resistor termination mode.
Terminating Resistor
a) 1 resistor mode - 3300 ohm.
b) 2 resistor mode - 2200 ohm and 3300 ohm.
Relay Specification:
a) 10A @ 24VDC.
b) Termination N/C, N/O and common.
Power Consumption: 12VDC @ 800mA.
C/W
a) 12V 3A Linear Power Supply.
b) Housed in Sturdy Metal Casing.
c) Space for Backup Battery.
Ordering Information