Operation Manual

caso Master P3 Plus 47
Attention
Do not use any flammable, acidy or alkaline materials or substances near the device, as
this may reduce the service life of the device and lead to deflagration when the device is
turned on.
17 Troubleshooting
This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:
17.1 Safety notices
Attention
Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
Improperly performed repairs can cause considerable dangers for the user and
damages to the device.
17.2 Fault indications
In the event of a fault, an error code will appear in the display; it describes the cause of the
fault. The following table assists in localizing and rectifying minor faults.
Fault
Possible Cause
To Rectify
- - -
Waiting status
Place a suitable pot/pan onto the induction cooking
field. The plate will work as usual
E01
Electronic control of low
voltage. (<140V)
Make sure the appliance is connected to the voltage
indicated on the rating label.
E02
Electronic control of excess
voltage (>260V)
E03
IGBT short circuit. Please send back to customer service.
E04 IGBT overheating protection
Eliminate the course of overheating. Once the
cooktop has cooled, the appliance can be put into
operation again.
E05
Overheating protection on
power mode (>150°C)
Eliminate the course of overheating. Once the
cooktop has cooled, the appliance can be put into
operation again.
E06
Temperature sensor
problem or short circuit
The temperature sensor underneath the glass
ceramic plate is defective. Please send back to
customer serivce.
E07
+E08
Technical defect Please send back to customer service.
Please note
If error messages continue to be displayed after an extended waiting period or after