ELECTRONIC CASH REGISTER TE-2200 TE-2400 DEALER'S MANUAL Version 1.0 August 2005 Eu CI Di U.K.
Introduction & Contents This manual is intended to be used as a reference to the TE-2200 and TE-2400 system. It provides details to allow whole understanding of the system capabilities, its operation, and how it can be used to solve many problems within the retail outlet. This manual consists of the following chapters: 1. Hardware configuration (for installation) This chapter describes the hardware of these models and their network systems. 2.
System configuration ........................................................................................ 11 Hardware configuration .............................................................................................. 11 General configuration ...................................................................................................................... 11 Hardware diagram .....................................................................................................................
Introduction & Contents Address code 17 (print control) ................................................................................................................. 44 Address code 18 (print control for guest receipt and slip) ........................................................................ 45 Address code 19 (order control) ............................................................................................................... 45 Address code 21 (message control) .......................
Programming item/key descriptors.......................................................................... 114 Programming procedure ................................................................................................................ 114 Programming data ......................................................................................................................... 114 Programming item/clerk descriptors by range .......................................................
Introduction & Contents Clerk detail link .............................................................................................................................. 134 Receipt message ........................................................................................................................... 134 Check endorsement ....................................................................................................................... 134 Slip/external printer message .......................
Report sample ............................................................................................................................... 160 Financial report .............................................................................................................................. 160 Individual item/key report ............................................................................................................... 160 Fixed total report ........................................................
Introduction & Contents Appendix: Peripheral device configuration ................................................... 191 UP-360......................................................................................................................... 191 SP-1300 ....................................................................................................................... 191 Quick scan 6000.........................................................................................................
Report header file ...................................................................................................... 202 Report header ................................................................................................................................ 202 Tax table file ............................................................................................................... 202 Tax table .................................................................................................
Introduction & Contents 10
System configuration System configuration Hardware configuration General configuration 1 2 3 4 5 6 7 8 Operator display Customer display (Popup display) Stroke keyboard (TE-2200) Touch keyboard (TE-2400) CF card slot cover Printer cover Mode switch Connector cover (opposite side) 2 6 2 6 1 1 8 7 8 7 3 5 5 TE-2200/2400 Dealer's Manual 4 11
System configuration CF card drawer external printer slip printer multi drawer scanner HHS-15 UP-360 SP-1300 Hardware diagram Main Display Popup display Journal printer Keyboard CPU Drawer 1 i/f 2 i/f Drawer Drawer RS232C COM1 PRL-CB-2 Drawer Multi drawer kit MDL-12 Popup disp. i/f MODEM or PC Flash Memory RAM RS232C COM2 CF card Slip printer Scanner HHS-15 SP-1300 Power supply 31AD-U/E Note: Shadowed device and dot line indicate option devices.
Display RECEIPT ON/OFF DATE/ TIME LIGHT System configuration Contrast control (Except for U.S. model) HELP DARK CONTRAST Input/output connectors Input /output connectors COM ports are located in the leftside connector cover.
System configuration Online configuration Peripheral ports and their connectable devices Model Device TE-2200 TE-2400 Drawer port COM port COM1 MODEM/PC ✔ External printer (Max.
IPL (Initial program loading) IPL should be made before initializing when the application program has been modified. The application programs are downloaded from PC (via COM port)/other terminal (via inline or COM port)/CF card to the internal flash memory.
IPL (Initial Program Loading) Via CF card (to send the IPL data to CF card) Operation 1. Set the mode switch to OFF position. 2. Open the CF card slot cover and insert the CF card securely. (Please check that the CF card is vacant. Refer to the “System utility section in PGM7”.) 3. Turn the mode switch to PGM position. 4. Enter “7” and press . 5. Enter “170” and press . 6. Enter “49” and press . (In case of quitting, press instead of .) 7.
Initialization Machine initialization procedure Initialization 1. Plug the power cord into an AC outlet. RECEIPT FEED 2. Hold down . REG2 REG1 OFF 3. Turn the mode switch to PGM position. X1 Z1 X2/Z2 RF PGM 4. Release . You should see “0000000000” on the display. If 10 zeros are not shown or another character are shown, immediately set the mode switch to OFF and restart from the beginning of this procedure. RECEIPT FEED JOURNAL FEED 5.
Initialization Worksheet (Initialize) Description Choice Yes = 0 No = 4 Print password of PGM mode, when flag clear operation is performed. Password in PGM3 ~ 7 mode Significant numbers Messages and descriptors are written in English = 0, French = 1, Spanish = 2, German = 4 Significant number Model for U.S.
Flag clear operation Initialization 1. Plug the power cord into an AC outlet. JOURNAL FEED 2. Hold down . REG2 REG1 3. Turn the mode switch to PGM position. X1 Z1 OFF X2/Z2 RF PGM 4. Release . You should see “FFFFFFFFFF” on the display. If 10 Fs are not shown or another character are shown, immediately set the mode switch to OFF and restart from the beginning of this procedure. 5. Press to complete.
Initialization Entering diag mode 1. Plug the power cord into an AC outlet. RECEIPT FEED 2. Hold down . REG2 REG1 3. Turn the mode switch to PGM position. X1 Z1 OFF X2/Z2 RF PGM 4. Release . 5. Enter “99990000” and press to enter the diagnosis. RECEIPT FEED JOURNAL FEED Password During initialize operation, you can program the password for PGM 3 ~ 7. If it is set, every time you enter PGM 3 ~ 7 mode, you must input this password by the following procedure.
Programming (General explanation) Program sub mode (P1 thru P7 mode) Programming • • • • • • • Program mode contains seven sub modes listed below. When you change the mode switch to PGM mode, the register is always in the PGM 1 mode. In case of using other mode, enter the sub mode number (2 ~ 7) and press . PGM1: unit price, rate, date, time, scanning PLU unit price maintenance PGM2: descriptor, name, message PGM3: machine feature (general function, clerk, etc.
Programming (General explanation) 22
File allocation (Program 5) File allocation program Programming procedure PGM 6 5s 6 : : : s 6 : : a 6s Mode switch File attribution code (see below.) File attribution code 0 1 2 3 4 5 daily sales ✔ ✔ ✔ ✔ ✔ ✔ Periodic 1 Periodic 2 ✔ ✔ ✔ TE-2200/2400 Dealer's Manual ✔ ✔ ✔ Program 5 File record number (see next pages.) File number (see next pages.
File allocation programming (P5) File number list File No.
Description Attribution 010 Monthly sales 20 31 --(periodic total 1) 20 31 --(periodic total 2) 20 31 --(daily consolidation) 20 31 --(periodic 1 consolidation) 20 31 --(periodic 2 consolidation) 20 31 018 Table analysis 28 99 --(periodic total 1) 10 99 --(periodic total 2) 10 99 --(daily consolidation) 10 99 --(periodic 1 consolidation) 10 99 --(periodic 2 consolidation) 10 99 020 Grand total 20 3 --(daily consolidation) 8 3 Check files 015 Check index 255 200 056 Separate check buffer 100 1500 060 Check
File allocation programming (P5) File No. File description Record length Max No.
Issuing program reading report of program 5 mode Issuing procedure PGM 6 5s 6 s Mode switch Report sample FILE0001 22bytes 10bytes FILE0002 35bytes 10bytes 99 99 99 99 — File name 99 — Sales file record length/No. of records of daily sales/periodic sales 1/periodic sales 2 99 — Consolidation file record length/No. of records of daily sales/periodic sales 1/periodic sales 2 100 100 --- -- — Hyphen means no record.
File allocation programming (P5) 28
Key allocation (Program 4) Key allocation program Programming procedure By pressing the appropriate key See Menu sheet No. section 6 4s6 PGM :000s6 Menu sheet number Mode switch 6:~ : Program 4 to other key This step can be skipped for transaction key. Set the same function 6 :::6 #-nn 6s Appropriate key • Record No. (department/transaction) • Function code • Random code or record No. (flat-PLU) (white key on the next page) By entering physical key code See Menu sheet No.
Key allocation programming (P4) Configuration of the physical key layout TE-2200 RECEIPT FEED JOURNAL FEED 071 C 064 062 060 054 048 042 036 030 024 018 081 076 070 065 063 061 059 053 047 041 035 029 023 017 080 075 069 7 8 9 058 052 046 040 034 028 022 015 079 074 068 4 5 6 057 051 045 039 033 027 014 016 078 073 067 1 2 3 056 050 044 038 032 026 020 021 077 072 066 0 011 012 055 049 043 037 031 025 019 013 TE-2400 for Eu
Function Add check Arrangement Birth date Bill copy Bottle return Cancel Cash amount tendered Charge Check endorsement Check print Check tender Clerk number Clock-in/out Coupon Coupon 2 Credit Cube Currency exchange Customer number Date/Time Decimal point Declaration Department Deposit Discount Eat-in EBT tender Enter Error correct Flat PLU * Food stamp status shift Food stamp subtotal Food stamp tender Help Ketten Bon Loan Lock out unused key Manual tax Media change Menu shift Merchandise subtotal Minus Mu
Key allocation programming (P4) Issuing program reading report of program 4 mode Issuing procedure PGM 64s 6 s Mode switch Report sample P04 .................... — Program read symbol 1 ----------------------00 0015-02 — Function character/rec-#/file-# 011-096 — Hard key code/function code .
Key function/machine feature (Program 3) General control program Programming procedure PGM 6 3s 6 : : 22s6 : : ~ : : a 6 s Mode switch Program data (Max.
Key function/machine feature (P3) Address code 04 (tax system, rounding, etc.) Description Choice Apply rounding for registration. Significant number (0 ~ 8) No rounding = 0, IF1 = 1, IF2 = 2, Danish = 3, Norwegian = 4, Singaporean = 5, Finnish = 6, Australian = 7, South Africa = 8 Tax system Receipt issuance: Allow amount tender in RF/REG– mode operation. a Cash drawer opening: b 1Immediately when the transaction is finalized. 2After validation compulsory is released.
Address code 05 (print control for receipt) Choice Print total line during finalization. a Yes = 0 No = 1 Time system: 1 24 hour system, 2 12 hour system b 1=0 2=2 Feed one line after issuing receipt. c No = 0 Yes = 4 Print consecutive number by double sized letter (up to 3 digits). a No = 0 Yes = 1 Buffered receipt print *1 b No = 0 Yes = 2 Skip item lines on journal. (journal skip) a No = 0 Yes = 1 Breakdown set menu printing on receipt, post receipt, guest receipt.
Key function/machine feature (P3) Address code 06 (calculation & operation control) Description a Yes = 0 No = 1 Force to register rate tax before finalization. b No = 0 Yes = 2 Force a money declaration by b, n, N before read/reset operation. c No = 0 Yes = 4 Force to press s before finalization a No = 0 Yes = 1 Allow credit balance while finalization. b Yes = 0 No = 2 Allow multiple refund/register minus operation. c Yes = 0 No = 4 Affect the result of +/-, %+/%-, mix & match to the item.
Address code 07 (menu & price shift) 1 Do not maintain 2 Until next menu shift specification 3 Within this transaction Maintenance of last price shift: 1 Do not maintain 2 Until next price shift specification 3 Within this transaction Choice Program code Initial value 1=0 2=1 3=2 : ; 1=0 2=1 3=2 : ; ; ; : ; Always “0” D8 D7 D6 Significant number (1 ~ 6) Sheet number of the parent menu sheet Summed up menu sheet 1 to parent menu sheet.
Key function/machine feature (P3) Address code 08 (print control for fixed total report) Description 38 Choice Print gross sales total on fixed total report (GROSS) a Yes = 0 No = 1 Print net sales total on fixed total report (NET) b Yes = 0 No = 2 Print cash in drawer total on fixed total report (CAID) c Yes = 0 No = 4 Print difference between money declaration and cash in drawer total on fixed total report (CATL, CA+, CA-) (Skip these lines, if “CAID” is set to skip.
Address code 09 (print control for fixed total report) Choice a Yes = 0 No = 1 Print tax 1 total on fixed total report (TX1) b Yes = 0 No = 2 Print tax exempt 1 total on fixed total report (EX1) c Yes = 0 No = 4 Print taxable amount 2 total on fixed total report (TA2) a Yes = 0 No = 1 Print tax 2 total on fixed total report (TX2) b Yes = 0 No = 2 Print tax exempt 2 total on fixed total report (EX2) c Yes = 0 No = 4 Print taxable amount 3 total on fixed total report (TA3) a Yes = 0 No = 1
Key function/machine feature (P3) Address code 10 (print control for taxable amount, till timer) Description Choice Print taxable amount 1 on receipt/journal. a Yes = 0 No = 1 Print taxable amount 2 on receipt/journal. b Yes = 0 No = 2 Print taxable amount 3 on receipt/journal. c Yes = 0 No = 4 Print taxable amount 4 on receipt/journal. a Yes = 0 No = 1 Print taxable amount 5 on receipt/journal. b Yes = 0 No = 2 Print taxable amount 6 on receipt/journal.
Address code 14 (currency exchange control) Choice Significant number (0 ~ 9) Monetary mode of CECA1 and CECK1 in fixed total report: Decimal for CECA1 and CECK1 in fixed total report: 1 Period = 0, 2 Comma = 1 Separator for CECA1 and CECK1 in fixed total report: 1 Comma = 0, 2 Period = 1 a b Separator for CECA2 and CECK2 in fixed total report: 1 Comma = 0, 2 Period = 1 a b Separator for CECA3 and CECK3 in fixed total report: 1 Comma = 0, 2 Period = 1 a b Separator for CECA4 and CECK4 in fixed total
Key function/machine feature (P3) Address code 15 (print control for reports) Description Zero skip department report. a Yes = 0 No = 1 Zero skip clerk report. b Yes = 0 No = 2 Zero skip transaction report. a Yes = 0 No = 1 Zero skip PLU report. b Yes = 0 No = 2 Zero skip hourly report. c Yes = 0 No = 4 Zero skip group report. a Yes = 0 No = 1 Zero skip monthly report. b Yes = 0 No = 2 Zero skip table analysis report.
Address code 16 (print control for grand total) Journal printing of the periodic 1 report Journal printing of the periodic 2 report Choice Program code Initial value Significant number (0 ~ 2) : ; : ; Significant number (0 ~ 2) a Yes = 0 No = 1 b Yes = 0 No = 2 No = 0 Yes = 1 Print consecutive number range of the day on daily fixed total report. Always “0000” D9 : Print grand total 1 on periodic 1/periodic 2 reset report. a Print grand total 2 on periodic 1/periodic 2 reset report.
Key function/machine feature (P3) Address code 17 (print control) Description Choice Money declaration compulsory (cash) in REG/RF mode a No = 0 Yes = 1 Money declaration compulsory (charge) in REG/RF mode b No = 0 Yes = 2 Money declaration compulsory (check) in REG/RF mode c No = 0 Yes = 4 No = 0 Yes = 1 Money declaration compulsory (credit) in REG/RF mode Always “0” Commission: 1 Taxable amount × commission rate 2 (Taxable amount + VAT) × commission rate Whenever pressing , , or
Address code 18 (print control for guest receipt and slip) Choice Significant numbers Maximum printing lines of slip (00 ~ 99) Slip printing speed: “Maximum printing lines of slip” is necessary, if you select “High”. Classify registered item by group on slip & guest receipt. a Low = 0 High = 2 b No = 0 Yes = 4 Always “0” Program code :: D8 D7 : Print date on slip & guest receipt. a Print time on slip & guest receipt.
Key function/machine feature (P3) Address code 21 (message control) Description Print graphic type logo. (If select “No”, character type logo is printed.) Choice a No = 0 Yes = 2 Print watermark on receipt. b No = 0 Yes = 4 Print commercial message on slip/guest receipt. a No = 0 Yes = 1 Print bottom message on slip/guest receipt. b No = 0 Yes = 2 Print intermediate message on slip/guest receipt. c No = 0 Yes = 4 Print bill top message. a No = 0 Yes = 1 Print bill copy message.
Address code 25 (condiment etc.) Choice Program code Enable to register a non-department link PLU. Yes = 0 No = 1 D4 Subtotal display: 1 Both “rounded” and “not rounded” subtotal 2 Only “not rounded” subtotal (This option is effective for selecting Eu/Aus rounding specification only.) 1=1 2=0 Previous item void: 1 By using ; ordinary procedure 2 By using 1=0 2=1 Restrict (to 0 or 5) on the last one digit for amount tender. Obey registration quantities of child PLU to its parent PLU.
Key function/machine feature (P3) Address code 28 (Euro) Description Choice Yes = 0 No = 1 Define Euro as the main currency. Significant number (0 ~ 2) Select rounding option: Round off = 0, Cut off = 1, Round up = 2 Significant numbers Exchange rate (within 6-digits) Decimal point position of exchange rate: Integer only = 0 1st decimal place = 1, 2nd decimal place = 2, 3rd decimal place = 3, 4th decimal place = 4, 5th decimal place = 5, 6th decimal place = 6 Example: (D8 ~ D2) 1 Euro = 1.
Address code 30 (Internal thermal printer control) Description Choice No = 0 Yes = 1 Journal compressed print (print by half height characters) Always “000” Program code Initial value : ; ;;; ;;; D4 D3 D2 D1 D4 D3 D2 D1 Address code 31 (scanning) Choice Program code Initial value Yes = 0 No = 1 D8 D8 a No = 0 Yes = 1 Print report before scanning PLU Z consolidation. * b No = 0 Yes = 4 Print scanning PLU code on receipt. a No = 0 Yes = 1 Print scanning PLU code on journal.
Key function/machine feature (P3) Address code 33 (batch PLU maintenance) Description Skip the record No. designation of batch maintenance PLU file. Choice a No = 0 Yes = 1 Skip the optimum stock field programming of batch maintenance PLU file. b No = 0 Yes = 4 Skip the unit price field programming of batch maintenance PLU file. a No = 0 Yes = 1 Skip the link field programming of batch maintenance PLU file. b No = 0 Yes = 2 Skip the character field programming of batch maintenance PLU file.
Address code 36 (store/recall/auto new check number) Description Reset the store/recall/auto new check starting number after open check reset report Store/recall/auto new check starting number (0000 = 0001) * Store/recall/auto new check ending number (0000 = 9999) * Choice Program code Initial value No = 0 Yes = 1 : ; Significant numbers (0000 ~ 9999) Significant numbers (0000 ~ 9999) :::: ;;;; D8 D7 D6 D5 D8 D7 D6 D5 :::: ;;;; D4 D3 D2 D1 D4 D3 D2 D1 Choice Program code Initial value Sig
Key function/machine feature (P3) Department key/flat-PLU key/PLU program (Batch feature programming) Programming procedure Department/flat-PLU key PGM To another department/flat-PLU key 6 3s 6 B MENU SHIFT Mode switch Department 6 :~: 6 6s Program data (12 digits) Flat-PLU To a new (not sequential) PLU Different program to the next PLU PLU PGM 6 3s 6 PLU No. +6 : ~ : 6 a 6s (Rec No.
Taxable status for the U.S.
Key function/machine feature (P3) Department key/flat-PLU key/PLU program (Individual feature programming) Programming procedure Department/flat-PLU key To another department/flat-PLU key Same program PGM 6 3s 6 : : 66s 6 : ~ : 6 Mode switch Program data Address code Department 6s Flat-PLU To a new (not sequential) PLU PLU Different program to the next PLU Same program PGM 6 3s 6 : :66s 6 PLU No.
Address code 12 (random code) Description PLU random code (only for PLU) Choice Program code Significant numbers :::::: Choice Program code D6 D5 D4 D3 D2 D1 Address code 13 (set menu) Description Set menu table/bottle link table record number (only for PLU) Significant numbers Set menu table/bottle link table file number (only for PLU) File number: set menu table = 28, bottle link table = 73 Significant numbers :::: D6 D5 D4 D3 :: D2 D1 Description Choice Significant numbers Optimum stock q
Key function/machine feature (P3) Address code 17 (Bon receipt control) Description Choice Program code : Significant number Number of Bon receipts (1 ~ 9) (If “0”, no Bon is issued.) D1 Other address code Address code 18 19 01 02 03 05 Description 04 09 Price change registration is enable. (Only effective for scanning PLU linked to this department) a No = 0 Yes = 1 Multiplication registration is enable.
Transaction key program Programming procedure To another transaction key PGM 6 3s 6 : ~ : 6 Program data Mode switch Transaction key 6s Program data , , Choice No = 0 Yes = 1 Restriction (to 0, 5) on last digit for amount tendered. (Only effective for or ) Significant number (0 ~ 9) Allowable number of validation printing (“0” means no limitation) *1 *2 *3 *4 *5 Force validation operation.
Key function/machine feature (P3) Description Restriction (to 0, 5) on last digit for amount tendered. Choice Program code No = 0 Yes = 1 D12 Significant number (0 ~ 9) Allowable number of validation printing (“0” means no limitation) *1 No = 0 Yes = 1 Force validation operation. *1 a No = 0 Yes = 1 Disable operation in REG2 mode. *1 b No = 0 Yes = 2 Disable operation in REG1 mode. *1 c No = 0 Yes = 4 Disable operation in RF/REG– mode. *1 Force batch slip printing.
, Description Allowable number of validation printing (“0” means no limitation) Choice Program code Significant number (0 ~ 9) D11 Force validation operation. No = 0 Yes = 1 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Force batch slip printing. a No = 0 Yes = 1 b No = 0 Yes = 4 Prohibit over tendering.
Key function/machine feature (P3) , Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Disable to change mode switch after registration. (only effective for ) Print characters on receipt, guest receipt, or slip.
, Description Restriction (to 0, 5) on last digit for amount tendered. Choice Program code No = 0 Yes = 1 D12 Significant number (0 ~ 9) Allowable number of validation printing (“0” means no limitation) No = 0 Yes = 1 Force validation operation. (only effective after receipt issuance) Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
Key function/machine feature (P3) <+ (PLUS)>, <- (MINUS)>, Description Multiple validation (If “No”, only one validation printing is possible.) Choice Program code Yes = 0 No = 4 D11 : ; Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 No = 0 Yes = 1 Allow credit balance.
Description Choice No = 0 Yes = 1 Restriction (to 0, 5) on last digit for amount tendered. a Multiple validation (If “No,” only one validation is possible.) b No = 0 Yes = 4 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Media definition: Significant number Maximum value (0 ~ 9) Number of zeros (0 ~ 9) TE-2200/2400 Dealer's Manual Program 3 Open cash drawer.
Key function/machine feature (P3) Description Multiple validation (If “No”, only one validation printing is possible.) Choice Program code Yes = 0 No = 4 D11 : ; Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 Key attribution Print when registered.
, Description Multiple validation (If “No”, only one validation printing is possible.) Choice Program code Yes = 0 No = 4 D11 : ; Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 Significant number Rounding: Round off = 0, cut off = 1, round up = 2 Allow key operation after .
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ;; Always “00” D8 D7 No = 0 Yes = 2 Prohibit manual entry.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 : Significant number Line number of auto-back feed before printing (0 ~ 9) D7 ;;;;;; Always “000000” D6 D5 D4 D3 D2 D1 , Description Choice Disable operation in RF/REG– mode.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Define amount symbol. (0, 1 ~ 4) (“0” means local currency symbol.) Significant number Define foreign currency totalizer. (0, 1 ~ 4) (“0” treats as “1”.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Force slip batch printing from the beginning of the transaction. If “No”, controlled by general function.) a No = 0 Yes = 1 Print issuing time (only effective when slip is printed from the beginning of the transaction).
Key function/machine feature (P3) Description Choice Program code Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Exempt tax 1 a Yes = 0 No = 1 ; Exempt tax 2 b Yes = 0 No = 2 : Exempt tax 3 c Yes = 0 No = 4 : (a+b+c) D9 • U.S.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 a Release table number compulsory. b Yes = 0 No = 2 Release check number compulsory. c Yes = 0 No = 4 Release credit balance error. (If “Yes,” you can finalize the transaction even if the subtotal is negative.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 The reviewed range of item: 2=0 1=1 Display “Check number”, “Table number”, and “Customer number”.
Description Choice Allowable number of validation printing (“0” means no limitation) Significant number (0 ~9) Force validation operation No = 0 Yes = 1 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : D11 : D10 : (a+b+c) D9 ;; Always “00” D8 D7 Include add-on tax. Print tray total when is pressed.
Key function/machine feature (P3) , , , Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ;;;;; Always “00000” D8 D7 D6 D5 D4 Significant number High digit limitation (HDL) for manually entered unit price (“9” means NOT allow manual entry.) : D3 ; Always “0” D2 Prohibit to change price greater than the preset price.
Key function/machine feature (P3) , Description Choice Program code Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Exempt tax 1 a Yes = 0 No = 1 ; Exempt tax 2 b Yes = 0 No = 2 : Exempt tax 3 c Yes = 0 No = 4 : (a+b+c) D9 • U.S.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ;;;;;;; Always “0000000” D8 D7 D6 D5 D4 D3 D2 A range of item correction: : 2=0 1=1 1From the beginning of this transaction 2Current receipt only D1 Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode.
Key function/machine feature (P3) Clerk program Secret number, drawer, check number programming Programming procedure To a new (not sequential) clerk To the next clerk 6 3s 6 : : 07s6 : : ~ : : 6 a 6 s PGM D12 D11 ~ D2 D1 Record No. Mode switch Data Description Choice Program code Check number for clerk interrupt Significant numbers Assigning drawer number: 00 ~ 02 Significant numbers ("00" means drawer 1.
Clerk other programming Programming procedure (individual) To a new (not sequential) clerk To the next clerk PGM 6 3s 6 : : 07s 6 : : s 6 : ~ : a 6 s Record No. Mode switch Program data Address code Programming procedure (by range) PGM 6 3s 6 99000007s 6 : : s 6 Address code Mode switch Ends “the last record”. Program 3 Starts “0001”.
Key function/machine feature (P3) Address code 68 (Commission rate) Description Choice Commission rate 1 (integer: 00 ~ 99) Significant numbers Commission rate 1 (decimal: 00 ~ 99) Significant numbers Commission rate 2 (integer: 00 ~ 99) Significant numbers Commission rate 2 (decimal: 00 ~ 99) Significant numbers Program code :: D8 D7 :: D6 D5 :: D4 D3 :: D2 D1 Address code 69 (Table number range) Description Choice Minimum range for table range (1 ~ 999999) (“0” means no programming.
Other programs Time range programming To a new (not sequential) record Programming procedure To the next record PGM 6 3s 6 : : 09s6 : ~ : 6 a 6 s Record No.
Key function/machine feature (P3) Tax table programming Programming procedure PGM Mode switch 8 3s 8 ::::s 8 (for the U.S., Singapore) Tax table 1 = 0125 Tax table 2 = 0225 Tax table 3 = 0325 { (for Canada) Tax table 1 = Tax table 2 = Tax table 3 = Tax table 4 = { 0125 0225 0325 0425 (for other area) Tax table 1 = Tax table 2 = : = Tax table 10 = { 0125 0225 : 1025 : : ^: : : : a Tax rate (4-digit for integer + 4-digit for decimal) ::::a Tax table maximum value (“0” means unlimited).
Example 1: Add-on rate tax Tax rate (2-digit for integer + 4-digit for decimal) ............................... Tax table maximum value ("0" means unlimited). ............................... Rounding/tax table system code ........................................................... Sum of a cyclic pattern ......................................................................... Number of values in each cyclic pattern ...............................................
Key function/machine feature (P3) Example 2: U.S. tax table without rate setting TAX (6%) $ .00 .01 .02 .03 .04 .05 .06 .07 .08 Price range Min. break point Max. break point $ .01 $ .10 .11 .24 .25 .41 .42 .58 .59 .74 .75 .91 .92 1.08 1.09 1.24 1.25 1.41 Max. break point Difference Upper Lower 10 – 0 = 10 24 – 10 = 14 41 – 24 = 17 58 – 41 = 17 74 – 58 = 16 91 – 74 = 17 108 – 91 = 17 124 – 108 = 16 141 – 124 = 17 17 Tax rate (2-digit for integer + 4-digit for decimal) ...............................
Example 3: U.S. tax table with rate setting Price range Min. break point Max. break point $ .01 $ .07 .08 .21 .22 .35 .36 .49 .50 .64 .65 .78 .79 .92 .93 1.07 1.08 1.21 1.22 1.35 1.36 1.49 1.50 1.64 1.65 1.78 1.79 1.92 1.93 2.07 Max.
Key function/machine feature (P3) Example 4: Add-in rate tax Tax rate (2-digit for integer + 4-digit for decimal) ............................... 10.00 % Rounding/tax table system code. .......................................................... 0003 (Cut off) PGM Mode switch 3s 8 ::::s 8 10a 8 0a 8 0003a 8 s Tax table No.
Set menu programming To a new (not sequential) record Programming procedure To the next record a Maximum 15 items can be set. PGM { 6 3s 6 : : 28s 6 Mode switch Record No. 6 MENU SHIFT B FlatB PLU :~ : 6+ }6s PLU code Rec #: within 4 digits Random code: within 6 digits Batch X/Z report programming To a new (not sequential) record Programming procedure To the next record Program 3 a 1st to 11th field PGM 6 3s 6 : : 29s 6 : ~ : 6 a 6 s Program data Record No.
Key function/machine feature (P3) Arrangement programming Programming procedure ** PGM * 6 3s 6 : ~ : 38s 6 A6 : ~ : a 6 Arrangement table No. (up to 6 digits) Record No. (up to 4 digits) Mode switch * 6 : ~: 6A6s Key operations * The same A should be pressed. ** Vacant record search: If you want to set an arrangement program to a new record, “vacant record search” is possible. (enter 0000 instead of entering a record No.
Mix & match programming Programming procedure To a new (not sequential) record To the next record PGM 6 3s 6 : : 51s6 Mode switch Record No.
Key function/machine feature (P3) Employee number programming Programming procedure To a new (not sequential) record To the next record PGM 6 3s 6 : : 61s 6 : ~ : 6a 6 s Mode switch Record No.
Scheduler programming Programming procedure PGM 6 3s 6 : : 62s 6 : ~ : 6 a 6 Record No. Mode switch To new record Program data 1 To the next record 6 : ~ : 6 a 6 : ~ : 6a 6s Description Program data 3 Choice Designate clerk by record number (“00” means the first record.
Key function/machine feature (P3) Job command table Description Job No. Group/terminal ID Parameter Default menu sheet number after signing on.
Bottle link table programming Programming procedure To a new (not sequential) total To the next record PGM 6 3s 6 : : 73s6 Mode switch Record No. 66 6 MENU B 6 PLU No. FlatB PLU 6 a 6s +6 Program 3 6 : : : : 04a 6 Record No.
Key function/machine feature (P3) I/O parameter table programming Programming procedure To a new record To the next record PGM 6 3s 6 : : 98s 6 : ~ : 6 a6 s Record No. Mode switch Program data Note: Please perform the following procedure after this program. 1. Power off the register, and connect all peripheral devices to COM ports. 2. Power on all peripheral devices. 3. Flag clear the register.
Reference (Baud rate/device table) Device Default baud rate Other selection Scanner (HHS-15) 2400bps (D2 = 0) 9600bps (D2 = 2) 4800bps (D2 = 3) Scanner (Quick Scan 6000) 9600bps (D2 = 0) 4800bps (D2 = 3) 2400bps (D2 = 4) External printer (UP-360) 9600bps (D2 = 0) 19200bps (D2 = 1) Slip printer (SP-1300) 9600bps (D2 = 0) None MODEM 19200bps (D2 = 0) 9600bps (D2 = 2) PC/ECR direct connection 19200bps (D2 = 0) None 4800bps (D2 = 3) Printer connection table programming Programming proced
Key function/machine feature (P3) Non PLU table programming To a new record To the next record Programming procedure 6 3s 6 : : 40s 6 : ~ : 6 a6 s PGM Program data Record No. Mode switch Program data Description Choice Program code : Significant number Non PLU type: Short version = 0, Long version = 1 D16 : No = 0 Yes = 1 Price check digit is included in the price field.
Scanning PLU maintenance programming Batch maintenance PLU programming Programming procedure A Proceeds the next vacant record. 63s 6 0070s 6 : ~ : 6a 6 PGM Record No.
Key function/machine feature (P3) Scanning PLU direct maintenance programming A Programming procedure 63s 6 0071s 6 PGM Mode switch 6 : 6 a6B 6 PRICE SHIFT { Action code 6 { Link-# B DEPT a } OBR B Code Scanning NLU B 6 : 6 *1 } 6 : ~ : 6a6 6 Unit price/quantity *1 : 6 a 6 : ~ : 6a 6 ~ Character Status *1 *1 A 6 : ~ : 6a 6 : ~ : 6 a 6 : Bottle link *1 Mix & match *1 : 6 a 6 s Optimum stock *1 100 *1 Skip by general function programming address code 32.
Scanning PLU individual programming Programming procedure PGM 0170 (Batch maintenance) 6 3s 6 0171 (PLU direct) s6 Mode switch B 6 : : 66 6 s 6 B 6 PRICE SHIFT Address code { OBR Code B Scanning B NLU } 6 6 B 6 : : 6 a 6 ~ Character Address code 11: link programming 6 { Link-# B DEPT a s Program 3 Address code 22: character programming B } 6 6 s B Address code 13,20,21,23: 6 other programming : ~ : 6 a 6 s Program data TE-2200/2400 Dealer's Manual 101
Key function/machine feature (P3) Program data Action code Description Action code: Addition = 0 Modification = 1 Deletion = 2 (Not effective for direct PLU maintenance) Choice Program code : Significant number D1 Unit price/quantity (Address code 21 for individual feature programming) Description Choice Integer part (0000 ~ 9999) Unit quantity (0.01 ~ 9999.
Status (Address code 23 for individual feature programming) Description Choice Program code :: Significant numbers Taxable status: See below. (In case of “00”, follow the linked department taxable status.) D6 D5 Always “0” ; Always “0” ; D4 D3 a No = 0 Yes = 1 Enable negative price. (Use this bit to change the status with that of the linked department.) b No = 0 Yes = 2 Hash (Use this bit to change the status with that of the linked department.
Key function/machine feature (P3) Issuing program reading report of program 3 mode Issuing procedure PGM 63s 6 s Mode switch Report sample P03.................... — Program read symbol CHECK CREDIT2 PD DEPT01 11-66 15-66 16-66 17-66 DEPT02 C01 67 68 69 70 C02 0001-09 0002-09 0003-09 0001-22 0002-22 0003-22 0001-25 TX1 TX1 TX1 104 0001-02 00000000000000 — Transaction key program 0002-02 — Key character/rec-#/file-# 00000000000000 — Key program 0003-02 00000000000000 0001-05 00000000000000 000000 @1.
Character (Program 2) Programming descriptors To other address code To the next address code Programming procedure Rec No. File No. 6 2s 6 : ~ : : : s 6 Character 6 a 6 s ☞ See “Entering characters” section.
Character programming (P2) Group character Up to 12 characters Address code 0106 0206 0306 : 9906 Contents Group 01 Group 02 Group 03 : Group 99 Initial character GROUP01 GROUP02 GROUP03 : GROUP99 Clerk character Up to 12 characters Address code Contents 0107 0207 0307 : 9907 Clerk 01 Clerk 02 Clerk 03 : Clerk 99 Initial character TE-2200/2400 (Eu) TE-2200/2400 (US) C01 C02 C03 : C99 Table analysis character Up to 12 characters Address code 0118 0218 0318 : 9918 Contents Table 01 Table 02 Table 03
Special character Contents 0123 main currency symbol (2), @ (2), No. (2), split pricing (2), not used (1) training filler (1), training symbol (1), not used (1), sub currency symbol (2) 0223 No. of item sold (2), No.
Character programming (P2) Address code 5023 5123 5223 5323 5423 5523 5623 5723 5823 5923 6023 6123 6223 6323 6423 6523 6623 6723 6823 6923 7023 7123 7223 7323 7423 7523 7623 7723 7823 7923 8023 8123 8223 108 Contents element title 8 of CF X/Z report (16) element title 9 of CF X/Z report (16) element title 10 of CF X/Z report (16) element title 11 of CF X/Z report (16) element title 12 of CF X/Z report (16) element title 13 of CF X/Z report (16) element title 14 of CF X/Z report (16) element title 15 of
Message Up to 24 characters Address code Contents Initial character YOUR RECEIPT 0132 1st line of logo message 0232 2nd line of logo message THANK 0332 3rd line of logo message CALL 0432 4th line of logo message 0532 1st line of commercial message 0632 2nd line of commercial message 0732 3rd line of commercial message 0832 4th line of commercial message 0932 1st line of bottom message 1032 2nd line of bottom message 1132 3rd line of bottom message 1232 4th line of bottom message
Character programming (P2) Report header Up to 12 characters Address code 0124 0224 0324 0424 0524 0624 0724 0824 0924 1024 1124 1224 1324 1424 1524 1624 1724 1824 1924 2024 2124 2224 2324 2424 2524 2624 2724 Contents Fixed totalizer report Transaction key report PLU report Department report Group report Cashier/clerk report Not used Hourly sales report Monthly sales report Not used Table analysis report Open check report Scanning PLU Hourly item PLU stock report Financial report Mix & match PLU by amount
Slip/external printer message Up to 40 characters (Contents are the same as file032.
Character programming (P2) Terminal connection table Up to 8 characters Address code 0191 Contents Physical No. 01 Initial character MC#01 AT command Up to 62 characters Address code 0196 0296 Contents Command set to MODEM on hook, confirmation Initial character AT COMMAND**** ATA ATI4 Error message Up to 16 characters Address code Contents 0180 0280 0380 : 23880 Error code Mode switch position changed before… Error code : Flash memory format is illegal.
X/Z guidance message Up to 16 characters Address code 0182 0282 0382 : 4882 Contents PLU range report message 1st line Input start No. message 1st line Input start No. message 2nd line : PLU reset message 1st line Initial character PLU by range Input start No. and press <#1> : PLU Z clear Program guidance message Up to 16 characters Contents 0183 0283 Range program message 1st line Input start No. message 1st line 0383 : 9783 Input start No.
Character programming (P2) Programming item/key descriptors Programming procedure Department key/transaction key To another department/transaction key 6 2s 6 PGM Mode switch Characters ☞ See “Entering Department key 6 Transaction key 6 s characters” section. PLU To a new (not sequential) PLU To the next PLU PGM 6 2s 6 PLU No. +6 (Rec No,: 4 digits) (Random code: 6 digits) Mode switch Flat-PLU key PGM 6 2s 6 Characters ☞ See “Entering characters” section.
Function Add check Arrangement Birth date Bill copy Bottle return Cancel Cash amount tendered Charge Check endorsement Check print Check tender Clerk number Clock-in/out Coupon Coupon 2 Credit Cube Currency exchange Customer number Date/Time Decimal point Declaration Department Deposit Discount Eat-in EBT tender Enter Error correct Flat PLU * Food stamp status shift Food stamp subtotal Food stamp tender Help Ketten Bon Loan Lock out unused key Manual tax Media change Menu shift Merchandise subtotal Minus Mu
Character programming (P2) Programming item/clerk descriptors by range Programming procedure PGM 6 2s 6 990000 : : s 6 Mode switch Department = 05 PLU/flat-PLU = 04 Starts “0001”. } Ends “the last record”. 6 : ~ : 6 a6 : ~ : 6 a 6 : ~: a 6s Start rec-# (Max. 4 digits) End rec-# (Max. 4 digits) Program data Department up to 16 characters Contents Initial character DEPT01 DEPT02 DEPT03 : DEPT99 Department 01 Department 02 Department 03 : : Department 99 PLU/flat-PLU up to 16 characters PLU No.
Entering characters By character keyboard TE-2200 character keyboard Example: Input “ A p p l e enter “DBL”“A” “SHIFT”“p” “p” “l” “e” “SPACE” 1 SHIFT JOURNAL FEED 7 OVR <— i “CAP”“J” “SHIFT”“u” c e “i” “c” “e” ”, - .
Character programming (P2) TE-2400 character keyboard Example: Input “ A p p l e enter “DBL”“A” “SHIFT”“p” “p” “l” “e” “SPACE” J u i “CAP”“J” “SHIFT”“u” 007 ; 014 - : 006 1 2 005 004 6 002 1 CAP e D d C 009 5 c 5 026 f V 016 t G v g B 023 b ^ 048 7 040 Y y H h N n 8 047 u J j K 037 069 0 ( 061 068 060 k L 015 022 029 059 051 058 C OVR 4 043 050 7 8 9 066 4 5 6 065 1 2 3 099 9 0 DBL 057 3 C 067 m 044 036 8 p l 052
By character code Every time you enter a character, choose character codes by the character code list (below) and press the ^ key to settle it. After you complete entering characters, press the - key to fix them.
Character programming (P2) Editing characters Correcting a character just entered OPERATION DISPLAY (character) 1 Enter LENON, instead of LEMON. LENON 1 Press left arrow key three times. LENON B 1 Override mode LENON “M” 1 Enter “M”. LEMON “L” “E” “N” “O” “N” yyy INS/ OVR Correcting and adding a PLU descriptor already set OPERATION 15+ “S”, “o”,“d”, “a”, “ ” INS/ B OVR “L” DISPLAY (character) 1 Enter “00”. 1 Enter PLU No. lemon 1 Enter “Soda” and “space”.
Issuing program reading report of program 2 mode Issuing procedure PGM 6 2s 6 s Mode switch Report sample GROSS NET CAID CATL GT1 GT2 GT3 0001-01 0002-01 0003-01 0004-01 0005-01 0001-02 0002-02 0003-02 0004-02 0001-05 0002-05 0003-05 0004-05 0001-06 0002-06 0003-06 0004-06 0001-07 0002-07 0003-07 0004-07 0001-18 0002-18 0003-18 0004-18 0001-20 0002-20 0003-20 • @No/ ** ™ NoCT@ LB *QT X BUSY 0001-23 0002-23 — Special character 0003-23 FIX TRANS PLU 0001-24 0002-24 — Report header character 0003-24
Character programming (P2) 122
Unit price/rate (Program 1) Date/time setting Date setting * PGM 61s 6 : : : : : : 6 Mode switch Year Month DATE/ B TIME 6 or C x Day Range: 2000 ~ 2099 * PGM 6 1s620: : : : : : 6 or 6C x Mode switch Year Range: 2000 ~ 2099 Month Day You can use , or instead of these keys.
Unit price/rate programming (P1) Programming the unit price and unit quantity (to PLU) To a new (not sequential) PLU Different program to the next PLU Same program PGM 6 1s 6 PLU No.+ 6 : ~ : 6 a 6 s Mode switch (Rec No.
Rate program PGM 6 1s 6 : : : : ^ : : : : 6 E 6 s Integer (Max. 4-digits) Mode switch Example: $1.00 = ¥110.50 ¥100 = $0.9050 2 2 1^105 0^905 Decimal (Max. 4-digits) Preset rate , , , , PGM 6 1s 6 : : ^ : : 6 Appropriate key 6s Integer Decimal (Max. 2-digits) (Max.
Unit price/rate programming (P1) Issuing program reading report of program 1 mode Issuing procedure PGM 6 1s 6 s Mode switch Report sample P01.................... — Program read symbol @100.00 — Transaction key unit price or rate @1.00 @1.00 10% CASH CHECK %DEPT01 1.2 DEPT02 1 126 0001-05 — Department descriptor/rec-#/file-# @1.00 — Unit quantity/unit price 0002-05 @2.
Program reading (Program 6) Issuing program reading report Issuing procedure Reading by file 6 6s 6 : : : s PGM Mode switch Reading code Reading by range PGM 6 6s 6 : : : s 6 : ~ : a 6 : ~ : a Mode switch Reading code End rec-# Start rec-# Report code Fixed totalizer Transaction key PLU Department Group Clerk Hourly sales Scanning PLU Table analysis Grand total General control Special character Report header Tax table Set menu table Batch X/Z Clerk detail link Receipt message Check endorsement me
Program reading (P6) Report sample Fixed totalizer P02.................... — Program 2 mode symbol GROSS NET CAID CATL 0001-01 — Fixed totalizer descriptor/rec-#/file-# 0002-01 0003-01 0004-01 Transaction key Program 1 P01.................... — Program 1 mode symbol CHECK CASH %- @10.00 — Transaction key descriptor/unit price @1.00 @2.20 10.24% — Transaction key descriptor/rate Program 2 P02....................
PLU Program 1 P01.................... — Program 1 mode symbol #000001 - #000010 PLU0001 0001-04 #000001 1.23 @10.00 PLU0002 0002-04 #000002 2.34 @30.00 — — — — PLU range PLU descriptor/rec-#/file-# PLU random code Unit quantity/unit price Program 2 P02.................... — Program 2 mode symbol Program 6 — PLU range #000001 - #000010 PLU0001 0001-04 — PLU descriptor/rec-#/file-# #000001 — PLU random code PLU0002 0002-04 #000002 PLU0003 0003-04 Program 3 P03....................
Program reading (P6) Department Program 1 P01.................... — Program 1 mode symbol — Department range #0001 - #0010 DEPT01 0001-05 — Department descriptor/rec-#/file-# 1.23 @10.00 — Unit quantity/unit price DEPT02 0002-05 2.34 @30.00 Program 2 P02.................... — Program 2 mode symbol — Department range #0001 - #0010 DEPT01 0001-05 — Department descriptor/rec-#/file-# DEPT02 0002-05 DEPT03 0003-05 Program 3 P03....................
Clerk Program 2 P02.................... — Program 2 mode symbol C01 C02 C03 — Clerk range #0001 - #0010 0001-07 — Clerk descriptor/rec-#/file-# 0002-07 0003-07 Program 3 P03....................
Program reading (P6) Table analysis Program 2 P02.................... — Program 2 mode symbol 0001-18 — Table descriptor/rec-#/file-# 0002-18 0003-18 TBL01 TBL02 TBL03 Program 3 P03.................... — Program 3 mode symbol TBL01 TBL02 TBL03 0001-18 — Table descriptor/rec-#/file-# 000000000000 — Program data 0002-18 000000000000 0003-18 Grand total P02.................... — Program 2 mode symbol 0001-20 — Grand total descriptor/rec-#/file-# 0002-20 0003-20 GT1 GT2 GT3 General control P03............
Report header P02.................... — Program 2 mode symbol FIX TRANS PLU 0001-24 — Report header character/rec-#/file-# 0002-24 0003-24 Tax table P03.................... — Program 3 mode symbol 0001-25 TX1 TX1 TX1 — Rec-#/file-# 12.3456% — Tax table program data 0000 5003 Program 6 Set menu table P03.................... — Program 3 mode symbol 0001-28 PLU0001 PLU0002 — Rec-#/file-# 0001-04 — Linked PLU descriptor/rec-#/file-# 0002-04 Batch X/Z Program 2 P02....................
Program reading (P6) Program 3 P03.................... — Program 3 mode symbol BATCH 01 00 BATCH 02 0001-29 — Batch report descriptor/rec-#/file-# 11-12-17-15-00 — Execution mode/report code 00-00-00-00-00 — Report code 0002-29 Clerk detail link P03.................... — Program 3 mode symbol 0001-30 GROSS 0002-30 NET — Rec-#/file-# 0001-01 — Linked total descriptor/rec-#/file-# 0002-01 Receipt message P02....................
Slip/external printer message P02.................... — Program 2 mode symbol — Rec-#/file-# 0001-34 ************************ — Message **************** 0002-34 Arrangement table P03.................... — Program 3 mode symbol 0001-38 REG1 1 2 DEPT01 000001 — Rec-#/file-#/arrangement table -# 204-000 — Function descriptor/key-#/function-# 001-000 002-000 026-051 Program 6 Character recall P02....................
Program reading (P6) Mix & match Program 2 P02.................... — Program 2 mode symbol DISCOUNT01 DISCOUNT02 DISCOUNT03 0001-51 — Descriptor/rec-#/file-# 0002-51 0003-51 Program 3 P03.................... — Program 3 mode symbol DISCOUNT01 @1.45 DISCOUNT02 0001-51 — Descriptor/rec-#/file-# 000003 — Discount amount/status 0002-51 Employee P03....................
One touch NLU P03.................... — Program 3 mode symbol — Rec-#/file-# 0001-77 — Linked scanning PLU descriptor Scanning PLU001 #1234567890123 — Scanning PLU code Help message P02.................... — Program 2 mode symbol 0001-85 ENTER NUMBER THEN 0002-85 PRESS KEY. — Rec-#/file-# — Program Program 6 Terminal connection table Program 2 P02.................... — Program 2 mode symbol MC#01 0001-91 — ID character/rec-#/file-# Program 3 P03....................
Program reading (P6) AT command P02.................... — Program 2 mode symbol — Rec-#/file-# 0001-96 AT command ************* — Program ************************ ************** 0002-96 Online password P02.................... — Program 2 mode symbol PASSWORD 0001-97 — Program/rec-#/file-# I/O parameter table P03.................... — Program 3 mode symbol 0001-98 0002-98 00000000000000 — Rec-#/file-#/program 00000000000000 Miscellaneous message P02....................
Error message P02.................... — Program 2 mode symbol #0001 E001 Wrong mode #0003 E003 — Guidance-No. (internal use) 0001-80 — Error code/rec-#/file-# (do NOT change) 0002-80 — Error message/rec-#/file-# 0003-80 Registration guidance message P02.................... — Program 2 mode symbol — Guidance No. (internal use) 0001-81 — Message/rec-#/file-# 0002-81 0003-81 0004-81 Program 6 #0001 Not Found PLU Input Unit Price ,and Press DEPT key #0002 X/Z guidance message P02....................
Program reading (P6) 140
Auto-program & system utilities (Program 7) Auto-programming Using the auto-program function makes it possible to save and load the terminal program files. Methods available for saving the terminal program are as follows: 1) Saving onto a personal computer connected through online. 2) Saving onto a CF card. To ensure quick recovery from a corrupted file resulting from user error or system failure, it is recommended that you maintain backup copies of current terminal programs on a file basis.
Auto-programming/system utilities (P7) Command code list File No.
File description 418 (periodic 1 consolidation) 518 (periodic 2 consolidation) 020 Grand total 320 (daily consolidation) Check files 015 Check Index 056 Separate check buffer 060 Check detail Clerk files 007 Clerk 030 Clerk detail link 011 Clerk detail 111 (periodic total 1) 211 (periodic total 2) 311 (daily consolidation) 411 (periodic 1 consolidation) 511 (periodic 2 consolidation) Time & attendance files 019 Time & attendance Scanning PLU files 016 Scanning PLU 040 Non PLU table 051 Mix & match table 15
Auto-programming/system utilities (P7) File No.
Other utilities Issuing system error log report 6 7s 6 1033s PGM Mode switch Report sample — Total working time — Start date — Rec-#/job No./error code (Refer to the appendix.
Auto-programming/system utilities (P7) Issuing CF card directory report 6 7s 6 1170s PGM Mode switch Report sample ---------(1170)--------- — — 001 PGM 1000.090 10,953 — 04-30-2004 12:34 — — 002 FILE0001.090 1,024 — 04-30-2004 12:34 ------------------------ Title Auto-programming title Index capacity Date/time Auto-programming file name File capacity Cf. The meaning of file name: FILEnnnn.
Set the AT command to default value PGM 6 7s 6 2310s Mode switch Set the AT command to MODEM Before executing this command, you should connect a MODEM. PGM 6 7s 6 4310s 6 a (Execution) Mode switch 6s Report sample (Cancellation) ---------(4310)--------Modem set -----------------------AT&V ACTIVE PROFILE: — Modem response Program 7 Normal End Set the graphic logo to the external printer Before executing this command, you should connect UP-350.
Auto-programming/system utilities (P7) 148
Manager operation This section describes modes and operations that are generally used by management only. Besides user programming procedure, it also describes how to perform clerk assignments for clerk interrupt function and set stock quantities. Manager control mode (X1 mode) • • • • • • • • • Manager control consists of the six operations listed below. Access to these operations can be restricted by password that makes it impossible to perform operations unless the correct password is input.
Manager operation Stock quantity maintenance (PLU/flat PLU/scanning PLU) You can make changes in actual stock quantities for PLU using the procedures described in this section. To add to the actual stock quantity of a PLU/flat PLU/scanning PLU To a new PLU To the next PLU Same value to the next PLU Procedure for PLU MGR 6 2s 6 : ~ : + 6 : ~ : 6 a 6 s PLU No.
To input the new stock quantity of a PLU/flat PLU To a new PLU Procedure for PLU MGR To the next PLU Same value to the next PLU 6 8s 6 : ~ : + 6 : ~ : 6 a 6 s Adjusted value PLU No.
Manager operation Programming for the Euro This procedure is used for defining main/sub currency, currency exchange rate for the Euro, and drawer number for sub currency at the same time. Please follow the guidance receipts issued in each time during this procedure.
Type 3 procedure Result printing Guidance message Guidance message 6 : : : : : : 6 a 6 : 6a 66 : 6 a (Execution) Currency conversion rate Drawer No. Unit price conversion * This step is skipped, if the rate had been already set. 6 s (Cancellation) Abortion: s Type 4 procedure Guidance message 6 : : : : : : 6 a 66 Currency conversion rate * This step is skipped, if the rate had been already set.
Manager operation Programming for the Australian GST This procedure is used for defining • Tax symbol (*) is printed. • Taxable amount (receipt) is skipped. • “GST INCLUDED” is set to the TX1 descriptor. • “TAXABLE AMT” is set to the TA1 descriptor. • Total line is printed even in direct (cash) sales. • Australian rounding is set. • “$” is set to the monetary symbol. • Print “MOF message” on receipt. • Tax (10% tax rate, add-in tax, fraction rounding off) is set to the tax table 1.
Read/reset report issuance Preparation for issuing report Money declaration There are two ways to declare the money in drawer amount; money declaration in the REG1/REG2/RF mode or money declaration in the X1/Z1 mode. Both declarations release “money declaration compulsory.” Money declaration in the REG1/REG2/RF modes The register stores the declaration amount, declaration over and declaration short totalizers for each payment medium, and you can issue reports in the status of each totalizer.
Read/reset report Programmability • • • • • • • • • • • Report issuance can be programmed with the following features: Suppress printing of zero total lines. Money declaration compulsory Report header message (report title) Print sales ratio Suppress printing of grand total Print two copies of the fixed total reset report. Print PLU number/random PLU codes on the PLU report and individual report. Clear (reset) actual stock quantity when the stock reset report programmed in a batch report is issued.
Clerk individual PLU individual by group Report code (Read: #=0 / Reset: # = 1) Consolidation file Daily Periodic 1 Periodic 2 Daily Periodic 1 Periodic 2 20017 2#117 2#217 20317 2#417 2#517 1020014 102#114 102#214 1020314 102#414 102#514 Clerk-No. Group-No. PLU individual by department PLU stock individual by group 2020014 1020064 202#114 ----- 202#214 ----- 2020314 ----- 202#414 ----- 202#514 ----- Department-No. Group-No.
Read/reset report Report code Report name (Read: #=0 / Reset: # = 1) Target-No. PLU range by record number Consolidation file Daily Periodic 1 Periodic 2 Daily Periodic 1 Periodic 2 Start number 10014 1#114 1#214 10314 1#414 1#514 Start rec-No.
Batch report 6 :::: 6a X1/Z1 X2/Z2 D4 D3 D2 D1 Mode switch Report code Note: If you skip to enter the report code, the 1st batch X/Z is executed. :::: D4 D3 D2 D1 The value (record No.
Read/reset report Report sample Financial report — X1 mode symbol/date/time X 03-04-2006 19:00 C01 MC#01 000001 — Clerk descriptor/Mc-No./consecutive No. X — Report header/title 0000071 — Report code FLASH DECLA EURO MONEY GROSS NET CAID CATL CACAID2 CATL2 CACR+ 2 FSID EBTTL $13,575.07 -1.36 ⁄26.33 -1.73 — — — — Declared amount of main currency 2734.973 $15,362.37 No 846 $13,601.80 $13,576.43 $13,575.07 -1.36 ⁄28.06 ⁄26.33 -1.73 $1.29 $4.63 -4.
Fixed total report Z 03-04-2006 C01 MC#01 FIX DECLA EURO MONEY 0001 — Report header/title/reset counter (Z only) 0001011 — Report code $13,575.07 -1.36 ⁄26.33 -1.73 — — — — 2734.973 — $15,362.37 — — NET No 846 $13,601.80 — CAID $13,576.43 — CATL $13,575.07 — CA$1.36 — CAID2 ⁄28.06 — CATL2 ⁄26.33 — CA$1.73 — CR+ 2 $1.29 FSID $4.63 — EBTTL -4.63 — -----------------------— RF No 1 $10.25 — — CUST CT 123 AVRG $110.58 — FEE $2.73 — + $10.25 — C-1 $2.38 — C-2 $57.
Read/reset report Transaction key report — Mode symbol/date/time Z 03-04-2006 19:15 C01 MC#01 000004 — Clerk descriptor/Mc-No./consecutive No. Z TRANS CASH 0001 — Report header/title/reset counter (Z only) 0001012 — Report code — Cash count — Cash total — Charge count CHKP No 846 $13,601.80 No 12 $31.80 No 1 VOID No — Void total — Validation count VLD RCT STORE RECALL No No No No CH 4 $64.
PLU report All PLU/range/menu report Z 03-04-2006 C01 MC#01 Z 19:25 — Mode symbol/date/time 000006 — Clerk descriptor/Mc-No./consecutive No. 0001 — Report header/title/reset counter (Z only) 0001014 — Report code PLU #000001 - #000500 — PLU range (range report only) PLU0001 83.933 — 25.27% $1,373.39 — OLD PRC $26.35 — RED PRC $18.98 — DISCOUNT $56.37 — — #000001 PLU0003 23 4.37% $63.44 DISCOUNT $0.00 #000500 -----------------------TL 207.933 — $2,871.63 — RED PRC $44.31 — DISCOUNT $86.
Read/reset report Best 50 report 1.......... PLU0001 83.933 25.27% $1,373.39 OLD PRC $26.35 RED PRC $18.98 DISCOUNT $56.37 #000001 2.......... PLU0050 67 21.19% $1,152.06 OLD PRC $66.75 RED PRC $38.96 DISCOUNT $43.37 #000045 50......... PLU0038 3 6.87% $373.39 OLD PRC $2.57 RED PRC $7.64 DISCOUNT $8.37 #000038 -----------------------TL 207.933 $2,871.63 RED PRC $44.31 DISCOUNT $86.
By group/department report GROUP01 PLU0001 #000001 PLU0002 ..........01 — Classification title (by group/dept.) — PLU character/optimum stock quantity 15 — Current stock quantity 73 * 15 3 — PLU code (4-digit) or Random code (6-digit) — * means out of optimum stock quantity #000002 GROUP02 PLU0010 #000010 PLU0011 ..........02 30 73 20 23 #000011 Department report All department report — Mode symbol/date/time Z 03-04-2006 19:30 C01 MC#01 000007 — Clerk descriptor/Mc-No./consecutive No.
Read/reset report Best 50 report — 1.......... DEPT01 83.933 — 25.27% $1,373.39 — OLD PRC $26.35 — RED PRC $18.98 — DISCOUNT $56.37 — 2.......... DEPT50 67 21.19% $1,152.06 OLD PRC $66.75 RED PRC $38.96 DISCOUNT $43.37 50......... DEPT38 3 6.87% $373.39 OLD PRC $2.57 RED PRC $7.64 DISCOUNT $8.37 -----------------------TL 207.933 — $2,871.63 — RED PRC $44.31 — DISCOUNT $86.
Clerk report — Mode symbol/date/time Z 03-04-2006 19:10 C01 MC#01 000008 — Clerk descriptor/Mc-No./consecutive No. Z CASHIER DECLA EURO MONEY C01 GROSS NET CAID CHID CKID CRID RF C-1 C-2 CLEAR 0001 — Report header/title/reset counter (Z only) 0001017 — Report code $13,575.07 -1.36 ⁄26.33 -1.73 — — — — Declared amount of main currency ...........1 2734.973 $15,362.37 No 846 $13,601.80 $13,576.43 $4.87 $273.97 $28.06 No 1 $10.00 $3.09 $8.93 No 325 — — — — — — — — — Clerk (manager) name/drawer No.
Read/reset report Hourly sales report — Mode symbol/date/time Z 03-04-2006 19:45 C01 MC#01 000010 — Clerk descriptor/Mc-No./consecutive No. Z 0001 — Report header/title/reset counter (Z only) 0001019 — Report code HOURLY 00:00->01:00 CT 12 GROSS $1,373.39 NET No 12 10.67% $1,373.39 — — — — — 01:00->02:00 CT 26 GROSS $4,253.64 NET No 12 2.67% $343.55 -----------------------— TL CT 4357 GROSS $12,871.63 — — NET No 3674 $12,881.
Table analysis report — Mode symbol/date/time Z 03-04-2006 19:55 C01 MC#01 000012 — Clerk descriptor/Mc-No./consecutive No. Z ANALYSIS 0001 — Report header/title/reset counter (Z only) 0001028 — Report code — TBL01 CT 34 10.66% $1,373.39 — TBL02 CT 27 29.24% $3,767.65 TBL20 CT 23 2.67%$344.84 -----------------------— TL CT 162 $12,881.
Read/reset report Scanning PLU report By group/department report — Mode symbol/date/time Z 03-04-2006 20:10 C01 MC#01 000015 — Clerk descriptor/Mc-No./consecutive No. Z SCAN PLU 0001 — Report header/title/reset counter (Z only) 2001026 — Report code DEPT01 ......01 SCAN_PLU001 382 17.07% $1,583.47 #4901234567894 SCAN_PLU002 382 38.01% $3,526.46 #4989012345674 SCAN_PLU003 382 10.49% $973.45 #4967890123454 -----------------------1253 $9,275.
Best 50 report DEPT01 ......01 — — 1...... — SCAN_PLU002 382 38.01% $3,526.46 — — #4934567890124 2...... SCAN_PLU001 285 #4912345678904 50..... SCAN_PLU003 72 10.49% $973.45 #4956789012344 -----------------------1253 — $9,275.83 Classified title Ranking Scanning PLU character/quantity Sales ratio/total Scanning PLU code Total of this classification DEPT02 ......02 1...... SCAN_PLU010 453 17.07% $1,583.47 #4990123456784 -----------------------1243 $10,375.
Read/reset report Scanning PLU stock report — Mode symbol/date/time Z 03-04-2006 20:22 C01 MC#01 000018 — Clerk descriptor/Mc-No./consecutive No. Z SCAN STOCK 0001 — Report header/title/reset counter (Z only) 2001065 — Report code ......01 — Classified title (by group/dept) 382.000 — Scanning PLU character/optimum stock quantity 458.347 — Actual stock quantity DEPT01 SCAN_PLU001 — Scanning PLU code #4901234567894 SCAN_PLU002 * 382.000 — * indicates stock shortage 105.
Time & attendance report — Mode symbol/date/time Z 03-04-2006 20:30 C01 MC#01 000021 — Clerk descriptor/Mc-No./consecutive No. Z ATTENDANCE 0001 — Report header/title/reset counter (Z only) 0001029 — Report code CSHR01 1111111111 03-03-02 08:55->17:09 08:16 03-03-03 08:56->17:11 08:17 03-03-04 08:55->--:---:------------------------TL 16:33 CSHR02 — Employee name/employee No.
Read/reset report 174
Application systems Scanning PLU You can register items by scanning. System configuration of the scanning PLU system Scanner Setup 1. After connecting a barcode scanner, program I/O parameter table to fit the scanner. 2. Allocate scanning PLU function keys (such as , , , and ). If you use multi price, allocate too. 3. Allocate scanning PLU files and non-PLU table file. 4. Program the non-PLU table to suit your scanning system. 5.
Application systems PLU maintenance There are three ways to maintain scanning PLU, i.e. not found PLU maintenance, batch PLU maintenance and direct PLU maintenance. Not found PLU maintenance When an item which code is not existed in the scanning PLU file is registered, the “Not found” error occurs. You can register this item by not found PLU maintenance procedure. After this maintenance, this item is registered without the “Not found” error and stored in the PLU file.
Scanning PLU registration By scanner/code input/one touch NLU key OPERATION Scan-PLU ($2.35) Item 1 ————————— (scan) PLU code 49012347 ————————————— Scan-PLU ($2.00) Item 2 ————————— (code) PLU code 123456 ————————————— Scan-PLU ($1.23) Item 3 ————————— (OTN) PLU code 49012354 ————————————— Payment Cash $5.58 RECEIPT “Scanning” 123 OBR 456B Scanning-PLU code and OBR key 1 PLU0001 #49012347 1 PLU0002 #123456 1 PLU0003 #49012354 TL CASH •2.34 — Scanning PLU code *1 •2.00 •1.23 •5.58 •5.
Application systems Price change operation When a scanning PLU item is programmed to enable to change price, you can change the unit price temporarily. The preset price in the scanning PLU file is not changed by this operation. You can restrict the temporary price is less/greater than the programmed unit price by the general function program. OPERATION PRC ($1.20) 100B CHG Scan-PLU ↓ Temporary unit price $1.00 Item ————————— PLU code 49012361 “Scanning” ————————— This item should be programmed as Dept.
Mix & match discount There are three types of mix & match processing: • Discount 1 (discount every required quantity) • Discount 2 (discount one time per one transaction) • Discount 3 (discount continuously) Mix & match discount affects to the item totalizer, link department totalizer and link department discount totalizer, when the “Net totaling” option is selected.
Application systems Discount type 3: In this type of processing, a discount is made when the quantity of a particular scanning PLU reaches a certain number during registration. And this discount is made after this item registration. OPERATION Scan-PLU ($0.34) “Scanning” ————————— Item PLU code 49012361 “Scanning” ————————— Quantity 4 “Scanning” ————————————— Mix & match discount is made. Discount type 3: 3/ $0.02 ————————————— Payment Cash $1.32 “Scanning” Mix & match discount is made.
Printing on the external printers You can print receipts/orders on external printer. Maximum 2 external printers can be connected to a terminal. It is possible to print out to another printer (i.e. another external, or internal R/J) for backup. The printouts from R/J printer and external printer can be divided into 3 types; 1. Receipt type, 2. Report type, and 3. Order type.
Application systems Printing control options for order Below shows the summary of the programmable options for order printing. Programmable option Number of feed lines before order printing (1 ~ 9) Number of feed lines after order printing (1 ~ 9) Cut order Show guidance for backup print of order. Alert when the external printer goes down. Baud rate Backup destination Merge the same item registration on order receipt. (Item consolidation) Breakdown set menu printing on order. Print order with amount.
Tips Future order This is an enhancement of the training function. By using the original training specification, the training clerk cannot accept any customer. Because no journal printing and no memory affection of this function is made. By using “Future order”, you can get this sales data and journal printing even if the transaction is registered by the training clerk. Usage Receipt issuance: OFF 1. Start training. (Sign on a training clerk.) During training 2.
Tips Automatic execution of Euro switchover by arrangement and scheduler The following sample shows an automatic execution program of arrangement and scheduler. Sample program Execution date/time: Currency definition type: Currency conversion rate: Drawer of sub currency: Unit price conversion: 31. December 2003 23:59 3 (Main currency = Euro, Sub currency = Local, Change = Euro) 1 Euro = 6.55957 F Franc Main Yes • Arrangement *2 PGM *1 6 3s 6 : ~ : 38s 6 A 6 : ~ : a 6 Arrangement table No.
Appendix: Calculation method The following calculation methods of totalizer memories are explained in this chapter. • All formulas in these explanations are calculated in the registration mode. • In the RF mode, the values in totalizers are calculated using the opposite sign. • In the REG– mode, the value in totalizers and counters are calculated using the opposite sign.
Appendix (Calculation method) Total or Counter Medium in drawer (Cash, charge, check, credit, Food stamp, EBT) Declared short medium amount (except Food stamp, EBT) Declared over medium amount (except Food stamp, EBT) Number of RF mode items RF mode amount Customer count Average sales per customer Check cashing service fee New balance fee Clerk commission total Foreign currency in cash drawer Foreign currency in check drawer Discount amount Coupon amount Item return amount Clear count Declaration count Ro
Appendix: Font code tables These models have the capability to print/display in Slavic, Greek, Cyrillic, Baltic, Arabic fonts. If you want to use these special font set, initialize the machine and enter the special initialization code (D14 ~ D12) before the original code 1 (D11 ~ D1). (Refer to the initialization chapter.
Appendix (Font table) Special font set Slavic (Windows code page 852) Special initialization code D14 D13 D12 = 010 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Ç 128 É 144 á 160 176 192 208 Ó 224 – 240 ü 129 Ĺ 145 í 161 177 193 Đ 209 ß 225 ˝ 241 é 130 ĺ 146 ó 162 178 194 Ď 210 Ô 226 â 131 ô 147 ú 163 179 195 Ë 211 M 227 ä 132 Ą 164 133 149 ą 165 g 134 ö L˘ ˘l 148 u 150 Ž ç 135 Ś 151 ž 242 ˙
Cyrillic (Windows code page 866) Special initialization code D14 D13 D12 = 030 Ä 128 ê 144 ‡ 160 176 192 Å 129 ë 145 · 161 177 Ç 130 í 146 ‚ É 162 131 ì 147 „ 163 Ñ 132 î 148 ‰ E 133 ï 149 Â Ü 134 ñ 150 á 135 ó 151 à Chara Code Chara Code 208 224 › 240 193 209 Ò 225 fi 241 178 194 210 Ú 226 ∏ 242 179 195 211 Û 227 π 243 164 180 196 212 Ù 228 Ï 244 165 181 197 213 ı
Appendix (Font table) Arabic Special initialization code D14 D13 D12 = 050 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code ° .
Appendix: Peripheral device configuration UP-360 Dip switch is located at the bottom of the printer. Function Reset by DTR reserved Protocol Transmision speed ON OFF Yes No --DTR/DSR fixed XON/XOFF See transmission speed setting Parity See paritysetting undifined Low power comsumption undifined --- --- Yes --- No --- ON OFF SP-1300 SW No. 1 2 3 4 5 6 7 8 9 10 UP-360 Bottom view Transmission speed setting bps 4800 9600 19200 38400 Parity setting SW No.
Appendix (Peripheral configuration) Quick scan 6000 Select these options: 1. Interface selection: SNI RS-232C interface selection 2. Baud rate: Baud rate = 9600 bps 3. Data format settings: Parity = Odd Stop bits = One Data bits = Eight bits 4. Software control: Hardware control = Enable CTS/RTS flow control Software control = Disable Xon/Xoff 5. RS-232C ACK/NAK options: ACK/NAK enable = Disable ACK/NAK 6. Setting symbology specific label identifiers: Transmit label I.D.
Appendix: File record format Fixed totalizer file Fixed totalizer (daily) File name: Fixed totalizer (daily) 0 12 Character 17 Counter File No.: 001 Max. allocatable records: 99(fixed) 22 Totalizer Fixed totalizer (periodic/consolidation) File name: File name: File name: File name: File name: 5 Counter Rec No. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 File No.: File No.: File No.: File No.: File No.
Appendix (File record format) Transaction key file Transaction key (daily) File name: Transaction key (daily) 2 File No.: 002 14 Function code 0 Character 21 Program 25 30 Max.
Department file Department (daily) File name: Department (daily) 16 Character 23 Program 25 28 Unit quantity 0 File No.: 005 Link 31 34 39 44 Max.
Appendix (File record format) Clerk file Clerk (programming) File name: Clerk (programming) 15 16 18 Character File No.: 007 23 Program 27 Commission rate 12 Clerk initial check # Drawer # Clerk # 0 33 Check # range Max.
Hourly sales file Hourly sales (daily) File name: Hourly sales (daily) 4 End time 2 Start time 0 9 14 No. of customer Gross total 19 No. of transaction File No.: 009 Max. allocatable records: 99 File No.: File No.: File No.: File No.: File No.: Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max.
Appendix (File record format) Scanning PLU files Scanning PLU file (daily) 35 37 39 40 @ Mix & match link Link 32 Last update date Character 29 Max. allocatable records: Depend on the model Bottle link PLU code 24 27 Program 7 8 Multi price flag 0 File No.: 016 Unit quantity File name: Scanning PLU 43 48 Minimum stock Counter 53 Totalizer 58 Actual stock Non PLU table file (program) File name: Non PLU table 0 File No.:040 Max.
One touch NLU table file File name: One touch NLU table 0 File No.:077 Max. allocatable records: 999 7 Scanning PLU code Mix & match table file Mix & match table file (daily) File name: Mix & match table (daily) Character 15 @ 18 23 Max. allocatable records: 99 28 30 Counter Totalizer Work 12 Program 0 File No.
Appendix (File record format) Table analysis file Table analysis (daily) File name: Table analysis (daily) 12 15 Character 18 Maximum check No. Minimum check No. 0 23 File No.: 018 Max. allocatable records: 99 File No.: File No.: File No.: File No.: File No.: 118 218 318 418 518 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 File No.: 019 Max. allocatable records: 99 File No.: 061 Max.
Grand total file Grand total (daily) File name: Grand total (daily) 0 12 Character File No.: 020 Max. allocatable records: 3 (fixed) File No.: 320 Max. allocatable records: 3 (fixed) 20 Totalizer Grand total (consolidation) File name: Grand total (consolidation) 0 8 Totalizer General control file General control File name: General control Max. allocatable records: 37 (fixed) 5 Appendix (File record format) 0 File No.: 022 Program Rec No.
Appendix (File record format) Special character file Special character File name: Special character 0 File No.: 023 Max. allocatable records: 42 (fixed) 16 Character See page nn of this manual for the detail of each record. Report header file Report header File name: Report header 0 File No.: 024 Max. allocatable records: 27 (fixed) 12 Character See page nn of this manual for the detail of each record. Tax table file Tax table File name: Tax table Max. allocatable records: 10 File No.
Batch X/Z file Batch X/Z File name: Batch X/Z File No.: 029 Max. allocatable records: 10 File No.: 032 Max. allocatable records: 42 Character Mode 12 14 15 16 17 18 19 20 21 22 23 24 X/Z code (1) X/Z code (2) X/Z code (3) X/Z code (4) X/Z code (5) X/Z code (6) X/Z code (7) X/Z code (8) X/Z code (9) X/Z code (10) 0 Receipt message file Receipt message File name: Receipt message 0 24 Rec No.
Appendix (File record format) Arrangement file Arrangement file File name: Arrangement File No.: 038 Max. allocatable records: 9999 File No.: 039 Max. allocatable records: 999 Flag Key code (1) Key code (2) Key code (3) Key code (4) Key code (5) Key code (6) Key code (7) Key code (8) Key code (9) Key code (10) 0 1 2 3 4 5 6 7 8 9 10 11 Character recall file Character recall File name: Character recall 0 40 Character Check print file Check print File name: Check print File No.: 041 Max.
System files Character key table file File name: Character key table 2 4 Max. allocatable records: depends on the model 6 1st character code 2nd character code 3rd character code 0 File No.: 046 Key/character key table record No.
Appendix (File record format) Key table file File No. Max. allocatable records: depends on the model 23 24 Record No./random PLU code File No. 19 20 Record No./random PLU code File No. 1516 Record No./random PLU code File No. 11 12 Record No./random PLU code File No. 7 8 Record No./random PLU code 3 4 Record No./random PLU code 0 File No.: 074 File No. File name: Character key table Key/key table record No.
Terminal connection table file File name: Terminal connection table 8 Max. allocatable records: 1 File No.: 093 Max. allocatable records: 7 File No.: 094 Max. allocatable records: 1 (fixed) File No.: 095 Max. allocatable records: 1 (fixed) 12 Program 0 File No.: 091 Machine ID.
Appendix (File record format) AT command file File name: AT command 0 File No.: 096 Max. allocatable records: 2 (fixed) 62 Character Online password file File name: Online password 0 File No.: 097 Max. allocatable records: 1 8 Character I/O parameter table file File name: I/O parameter table 0 File No.: 098 Max. allocatable records: 2 (fixed) 4 Program System error log file File name: System error log Max. allocatable records: 99 File No.: 047 Max. allocatable records: 168 (fixed) File No.
Guidance message files Error message file File name: Error message 0 File No.: 080 Max. allocatable records: 191(fixed) 16 Character Meaning 001 002 003 004 Error code (do NOT change) Mode switch position changed before finalization. Error code (do NOT change) Clerk button pressed before finalization of a registration being performed under another clerk button. The signed on clerk differs from the clerk performed the tracking check registration.
Appendix (File record format) Rec-No. 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 210 Meaning Error code (do NOT change) Finalization of a transaction attempted without confirming the subtotal.
115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137~138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157~158 159 160 161 162~164 165 166 167 168~169 170 171 172 173 174 175 176 177 178 179 180 181 182 Meaning Error code (do NOT change) Attempt to finalize a transaction without specifying or . (1/2) Attempt to finalize a transaction without specifying or .
Appendix (File record format) Rec-No. 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 212 Meaning Error code (do NOT change) Attempt to print the last separated transaction on slip. (1/3) Attempt to print the last separated transaction on slip. (2/3) Attempt to print the last separated transaction on slip.
Miscellaneous message file File name: Miscellaneous message 0 File No.: 078 Max.
Appendix (File record format) Printing guidance message file File name: Printing guidance message 0 File No.: 079 Max. allocatable records: 85(fixed) 24 Character Rec-No.
Rec-No.
Appendix (File record format) X/Z guidance message file File name: X/Z guidance message 0 File No.: 082 Max. allocatable records: 48(fixed) 16 Character Rec-No. 001 002 003 --004 005 006 ----------007 008 009 010 ----011 ----012 ----013 ----014 ----015 ----016 ----------017 ----------018 ----------- 216 Meaning PLU range report message 1st line Input start No. message 1st line Input start No. message 2nd line PLU range report message 1st line (quote from rec-001) Input end No.
Meaning PLU best report message 1st line Input start No. message 1st line (quote from rec-002) Input start No. message 2nd line (quote from rec-003) PLU best report message 1st line (quote from rec-016) Input end No. message 1st line (quote from rec-004) Input end No. message 2nd line (quote from rec-005) PLU inactive report message 1st line Input start No. message 1st line (quote from rec-002) Input start No.
Appendix (File record format) Program guidance message file 0 File name: Program guidance message 16 File No.: 083 Max. allocatable records: 93(fixed) Character Rec-No. 001 002 003 --004 005 --006 007 008 009 --010 --011 012 013 014 015 016 017 --018 ----------019 --020 --021 --022 023 ----024 025 026 ----------------------------027 ----- 218 Meaning Range program message 1st line Input start No. message 1st line Input start No.
Meaning Batch maintenance programming message 1st line Input batch maintenance record No.
Appendix (File record format) Rec-No. 064 065 066 067 068 --069 070 071 ----072 ----073 074 075 076 ----077 ----078 ----079 ----080 ----081 ----082 ----083 ----084 085 086 ----087 088 089 090 091 092 --093 --------094 095 096 097 ----------- 220 Please wait message Meaning Default (English) message Please wait PLEASE WAIT Auto-program (register to register) message Input target machine No. message 1st line Input target machine No.
Registration guidance message file File name: Registration guidance message 0 File No.: 081 Max.
Appendix (File record format) Help message file File name: Help message 0 File No.: 085 Max. allocatable records: 199 (fixed) 24 Character Note: It is necessary to allocate this file, if you want to make your original help. Rec-No.
Meaning Second help item message (14/53) Second help item message (15/53) Second help item message (16/53) Second help item message (17/53) Second help item message (18/53) Second help item message (19/53) Second help item message (20/53) Second help item message (21/53) Second help item message (22/53) Second help item message (23/53) Second help item message (24/53) Second help item message (25/53) Second help item message (26/53) Second help item message (27/53) Second help item message (28/53) Second he
Appendix (File record format) Rec-No.
Meaning Fifth help item message (37/64) Fifth help item message (38/64) Fifth help item message (39/64) Fifth help item message (40/64) Fifth help item message (41/64) Fifth help item message (42/64) Fifth help item message (43/64) Fifth help item message (44/64) Fifth help item message (45/64) Fifth help item message (46/64) Fifth help item message (47/64) Fifth help item message (48/64) Fifth help item message (49/64) Fifth help item message (50/64) Fifth help item message (51/64) Fifth help item message
Appendix (File record format) 226
Appendix: Compulsory This section explains the priority compulsions and the methods to solve them. Compulsions at the first item registration Priority Error code Meaning 1 E017 Force to enter check number. 2 3 E018 E019 Force to enter table number. Force to enter the number of customer. Released by ✔ ✔ ✔ Action Register check number by , , . Register table number. Register the number of customer.
Appendix (Compulsory) 228
Appendix: Error code E003 Wrong operator E004 Error INIT/FC E005 Insufficient memory E008 Please sign on E009 Enter password E010 Close the drawer E011 Close the drawer E016 Change back to REG mode E017 Enter CHK/TBL number E018 Enter Table number E019 Enter number of customers E021 No DEPT Link E023 Stock shortage E024 No stock E026 Enter condiment/ preparation PLU E029 In the tender operation E030 Press RATE TAX key E031 Press ST key E032 Press FSST key E033 Enter tendered amount E035 Change amount exce
Appendix (Error code) Error code (…continued) Error Message code E049 CHECK memory full Check tracking index memory full. Finalize and close the check number currently used. E050 DETAIL memory full Check tracking detail memory full. Finalize and close the check number currently used. E051 CHK/TBL No. is occupied Attempt to made use to open a new check using a number that is already used for an existing check in check tracking memory.
System error code Meaning File I/O errors 750 File cannot be created. 751 No designated drive 752 FCB area shortage of flash memory 753 No appropriate record number is designated. 754 No partition exists. 755 No vacant record is remained. 756 Changing is not permitted. 757 The designate file cannot be found. 758 The same file has already existed. 759 The same page has already existed. 760 No vacant record is remained. 762 The contents of internal memory and CF card are different.
Appendix (Error code) 232
Index A action code 102 activation of batch maintenance 99 add check 31, 79, 115 add-in rate tax 88 add-in tax 186 add-on rate tax 85 add-on tax 185 Arabic font 190 arrangement 25, 31, 69, 90, 115, 204 arrangement table 25, 127, 135 AT command 24, 112, 127, 138 AT command file 208 Australian GST 47, 154 auto sign-off 46 auto-program 141, 144 average sales per customer 186 B backup system for external printer 181 Baltic font 189 barcode system 175 batch feature programming 52 batch maintenance PLU 25, 99, 1
Index D G date order 33 date setting 123 decimal point 31, 115 declaration 31, 38, 79, 115, 160, 161, 167, 186 deleting a file from CF card 146 department 24, 31, 52, 54, 115, 116, 127, 130, 159 department best 50 159 department file 195 department report 165 deposit 31, 63, 115 descriptor 105 diag mode 20 direct maintenance PLU 25, 176 direct maintenance PLU file 198 discount 31, 65, 115, 125, 185, 186 drawer 12, 14, 34, 38, 40, 58, 59, 80, 149, 152 drawer assignment 149 general control 26, 127, 132 gene
online password file 208 open 31, 115 open check 31, 79, 115, 159 open check report 169 open2 31, 73, 115 operation control 36 operation start date file 207 operator display 11 operator read/reset 31, 115 operator x/z 74 order control 45, 55 M N net sales 185 new balance 31, 59, 115, 125 new balance fee 186 new check 31, 76, 115 new/old check 31, 76, 115 no sale 31, 79, 115 non add 31, 68, 115 non add/no sale 31, 68, 115 non PLU table 25, 98, 127, 135, 175 non PLU table file 198 not found PLU 177, 178, 17
Index program / message / buffer file 26 program 1 programming in X1 mode 149, 154 program guidance message 26, 113, 127, 139 program guidance message file 218 program reading report of program 1 126 program reading report of program 2 121 program reading report of program 3 104 program reading report of program 4 32 program reading report of program 5 27 program sub mode 21 Q quantity/for 31, 76, 115 Quick Scan 6000 14, 192 R random code 55 rate 125 rate tax 31, 66, 115, 125 read/reset report 155 recall
T table analysis 25, 89, 106, 127, 132, 159 table analysis file 200 table analysis report 169 table number 31, 79, 115 table number range 82 table range 83 takeout 31, 78, 115, 183 tax exempt 31, 115 tax shift 31, 71, 115 tax system 34 tax table 26, 84, 127, 133 tax table file 202 taxable amount subtotal 31, 115 taxable status 53, 62, 64, 65, 91, 103 taxable subtotal 71 terminal connection table 24, 112, 127, 137 text print 31, 115 text recall 31, 115 three zero 31, 115 till timer 40 time & attendance 159 t
CASIO COMPUTER CO., LTD.