Specifications

Table Of Contents
— 7 —
1-3. Flash operation and recharge operation
Apply 6.0 ± 0.1 V voltage on DC in jack.
Set QV-5000SX in “REC” mode.
Perform after flash adjustment.
(1) Shoot a picture with flash ON.
(2) Shoot in red eye reduction mode.
(3) Shoot in macro mode.
(4) Set QV-5000SX in “PLAY” mode and check the pictures taken.
(5) Monitor the trigger waveform of (1), (2) and (3) on a digital oscilloscope and make sure there are
no errors.
(6) Shoot a picture with flash OFF. (Make sure there is no flash)
(7) Make sure that the charging current is less than 1.3 A.
Note: Make sure that the pictures taken in steps (1) and (2) are not whitish, dark or erroneously
colored.
Flash lens face
Monitor
Digital oscilloscope
Probe close to
flash lens face
QV-5000SX
Earth of hte probe
Should be hooked as shown above.
TIME : 1.0 µsec/DIV
VOLTS: 1 V/DIV (AC mode)