such devices, it is recommended that you can enable only those symbologies that are being
used for scanning and disable all other symbologies.
Report Check: Check this box to report (or return) the check digit as part of the barcode
data.
NOTE: Each symbology has a separate set of configuration parameters associated with
it. Selecting the symbology from the list will make these visible for configuration and
update. Please refer to the individual barcode symbology references in the
documentation for the handheld device.
Advanced: This button opens advanced configuration dialog for the selected barcode
symbology. All settings configured and updated in this dialog are associated with the
currently selected symbology.
Data Length Min: This is the minimum length, in characters, for the decoded barcode.
Specifying a minimum length will require every scanned barcode to be at least the
minimum length. Possible values depend on the symbology. Default is usually 0 which
implies no minimum length.
Data Length Max: This is the maximum length, in characters, for the decoded barcode.
Specifying a maximum length will require every scanned barcode to be at most the
maximum length. Possible values depend on the symbology. Default is usually 0 which
implies no maximum length.
Strip Data Start: This is the number of characters to be stripped from the beginning of
the decoded barcode. Default is 0, which does not strip any characters.
Strip Data End: This is the number of characters to be stripped from the end of the
decoded barcode. Default is 0, which does not strip any characters.
Custom ID: Checking this box will enable the Custom ID when used with the %L pre-
amble or post-amble code. A %C in a pre-amble or post-amble will insert the custom ID
regardless of the setting of this box. The custom ID text may be configured in the edit
box.
NOTE: Custom ID field may be used when you have a requirement to add
different pre-ambles or post-ambles for two or more barcode symbologies. For
example you may need to add a prefix “UPC” to all UPC-A barcodes and a prefix
“C128” to all Code 128 barcodes. In such a case, you can set a custom id of