Specifications
55
[Auto Power OFF] Section
Auto Power OFF Imager’s APO timer Specify in the range of
0 to 1800 (in second),
“0” disables APO, “1
to 1800” turns off the
power to the Imager
after the time period
has elapsed.
0
[Indicator] Section
LED Specify turning on the LED when
scanning is complete.
0; disable, 1; enable in
green, 2; enable
“success” in green and
“failure” in red
2
Buzzer Specify turning on the buzzer when
scanning is complete.
0; disable, 1; enable 1
Vibrator Specify turning on the vibrator when
scanning is complete.
0; disable, 1; enable 1
[Decode Window] Section
Enable Specify decode window mode. 0; disable, 1; mode 1,
2; mode 2, 16; user
define
0
Left Specify left side coordinate of
decode window.
Specify from 0 to 751 0
Top Specify top side coordinate of
decode window.
Specify from 0 to 479 0
Right Specify right side coordinate of
decode window.
Specify from 0 to 751 751
Bottom Specify bottom side coordinate of
decode window.
Specify from 0 to 479 479
[Decode Reverse] Section
Enable Specify decode reverse mode 0; No reverse
1; Reverse
2; Both
0