Angle
1D (Code39 10mil (0.25mm)) ±35 degree At 110 mm away from the
IT-9000.
2D Stack type (PDF417 10mil(0.25mm)) ±35 degree At 110 mm away from the
IT-9000.
Pitch
angle
2D Matrix type (Aztec 20mil(0.5mm)) ±35 degree At 110 mm away from the
IT-9000.
1D (Code39 10mil 0.25mm)) ±40 degree At 110 mm away from the
IT-9000.
2D Stack type (PDF417 10mil(0.25mm)) ±40 degree At 110 mm away from the
IT-9000.
Skew
angle
2D Matrix type (Aztec 20mil(0.5mm)) ±35 degree At 110 mm away from the
IT-9000.
Dead zone
±5 degree
(Pitch, Skew)
At 110 mm away from the
IT-9000.
1D (Code39 10mil (0.25mm)) 360 degree At 110 mm away from the
IT-9000.
2D Stack type (PDF417 10mil(0.25mm)) 360 degree At 110 mm away from the
IT-9000.
Tilt angle
2DMatrix type (Aztec 20mil(0.5mm)) 360 degree At 110 mm away from the
IT-9000.
Lighting
100 to 80,000Lux
PCS
1D (Code39 10mil (0.25mm)) 0.45 or more 5 digits
2D Stacked (PDF417 10mil (0.25mm)) 0.45 or more 100 digits
2D Matrix (Maxi Code 35mil (0.889mm)) 0.45 or more 52 digits
Viewing angle
V_Angle = 26 degree
H_Angle = 35 degree
Operation temperature
High 50°C
Low -10°C See note 5.
Notes:
1. All the specifications in the table are defined under the basic condition. See next page.
2. A small amount of variation in reading range may occur according to each symbology.
3. All no. of digits are defined using numeric only. With alphanumeric and ASCII characters, no. of digits
of a symbology is defined by the specifications and setting on a barcode print application software.
4. All “Recommend no. of digits” and “Maximum no. of digits” are reference only. They may vary
according to barcode printing quality, surrounding environment in where scanning barcode takes place,
etc.
5. Scanning barcode will take place in the temperature of -20°C, but, the scanning ability may deteriorate.