4.2 Electrical Performance
4.2.1 IT-3100
The following table explains electrical performance on the IT-3100 series (all models).
Table 4.12
Parameter Specification Remark
Power consumption DC 4.5A, 7.4V to 10.0V
Anti-static strength
Malfunction ±6 KV
Destruction ±12 KV
150 pF/330 ohm
4.2.2 HA-B30CHG
The following table explains electrical performance on the Cradle-type Battery Charger
(HA-B30CHG, HA-B30CHG-CN).
Table 4.13
Parameter Specification Remark
Approx. 0.1 A When IT-3100 is not mounted on. Current consumption
Approx. 2.2 A While supplying power and
transmitting data.
Voltage DC12V±5%
Anti-static strength
Malfunction ±6 KV
Destruction ±12 KV
150 pF/330 ohm
- Pulse frequency
: 5 KHz
- Burst cycle
: 300 milliseconds
- No. of pulses
: 75 pcs
Line noise strength
(Level of malfunction)
1,000 V
- Burst period
: 15 milliseconds
Power interruption 10 milliseconds or less