GRAPH35+ E (Version 2.10) Logiciel Mode d’emploi

If this is the trigger
source:
Do this next:
[EXE] key Press w to finalize Trigger Setup and return to the Advanced
Setup menu.
Count Down Specify the countdown start time. See To specify the
countdown start time below.
CH1 Specify the trigger threshold value and trigger edge direction.
See To specify the trigger threshold value and trigger edge
type, To configure trigger threshold, trigger start edge, and
trigger end edge settings on page 3-11 or To configure
Photogate trigger start and end settings on page 3-12.
SONIC Specify the trigger threshold value and motion sensor level.
See To specify the trigger threshold value and motion sensor
level on page 3-12.
Mic Specify microphone sensitivity. See To specify microphone
sensitivity below.
[START] key Press w to finalize Trigger Setup and return to the Advanced
Setup menu.
uu
uu
u
To specify the countdown start time
1. Move the highlighting to Timer”.
2. Press 1(Time) to display a dialog box for specifying the countdown start time.
3. Input a value in seconds from 1 to 10.
4. Press w to finalize Trigger Setup and return to the Advanced Setup menu.
uu
uu
u
To specify microphone sensitivity
1. Move the highlighting to Sense and then press one of the function keys describe below.
3. Perform one of the following operations, in accordance with the trigger source that was
selected in step 2.
To select this level of microphone sensitivity: Press this key:
Low 1(Low)
High 3(High)
Medium 2(Mid)
3-10
Using Advanced Setup
2. Press w to finalize Trigger Setup and return to the Advanced Setup menu (page 3-1).