User manual - fx-9860GII_Soft
13-8
  - Clipboard and history data (Including the “SYSTEM” data item.)
  - e • ACT  mode data* 
1 
  - S • SHT  mode data* 
1
  * 
1 
 Can be transferred from an fx-9860G II  SD, fx-9860G II , fx-9860G AU PLUS, fx-9860G SD 
(OS 2.0), fx-9860G (OS 2.0) or fx-9860G AU (OS 2.0) calculator.
  • Program data is transferred as-is.
    However, any command in a transferred program that is not supported by the fx-7400G 
II  
will be replaced by the at sign (@). Running such a program on the fx-7400G II  will cause an 
error.
u Sending Data from an OS 2.0 Calculator to any Older Model Calculator
  The following are general rules that apply when transferring data from an OS 2.0 calculator to 
an fx-9860G series or CFX-9850G series calculator.
  • The following data is not transferred.
  - String memory data
  - TVM  mode bond calculation and depreciation calculation data
  - STAT  mode function and variable data for which there is no corresponding function for 
variable on the receiving calculator model (Example: 
 
2 
 GOF Test calculation result data, 
etc.)
  • The following data is converted by the OS 2.0 calculator to a format that is supported by the 
receiving calculator model before it is sent.
  - GRAPH  mode, DYNA  mode Graph Type setting data
    When transferring to an fx-9860G series or CFX-9850G series calculator, X=, X>, X<, X t, 
and X s type expressions are converted to an X=c type expression 
  - Graph line type setting data
    When sending to a CFX-9850G series calculator, line settings are converted as follows 
before being sent: Normal: Blue; Thick: Orange; Broken, Dotted: Green. 
  - STAT  mode Graph1, Graph2, and Graph3 setting data
    When sending to an fx-9860G series calculator, pie and bar type graphs are converted to 
ScatterPlot before being sent. Other settings are not sent.
  • Program data is transferred as-is. 
    However, any command in a transferred program that is not supported by the other model 
calculator will be replaced by the at sign (@). Running such a program on the other model 
calculator will cause an error. 
  • Refer to the following if an error message appears on the OS 2.0 calculator when you are 
sending data to another calculator model.
     Invalid Data Size
   - Matrix data exceeds 256 rows or 256 columns* 
1 
  - List data exceeds 256 lines
  - Table data exceeds 256 rows
  - Recursion table data exceeds 256 lines* 
1 
* 
3 
  - EQUA  mode input data includes 4 to 6-degree equation