User Guide

Specifications
Accuracy at normal temperature: ±20 seconds a month
Stopwatch: Measuring Capacity: 9'59" (10 minutes)
Measuring Unit: 1 second
Measurements: Elapsed time; split time; two finishes
Battery: One silver oxide battery (Type: SR920SW)
Battery Life: Approximately 3 years
Specifications are subject to change without notice.
Perform the following procedure if the stopwatch hands do not return to their 0 (zero)
positions when you reset the stopwatch.
Correcting the 0 Positions of the Hands
Pull the Crown out to Click 2.
Use A (clockwise) and B (counterclockwise) to move the
Stopwatch Second Hand
to 12 o’clock and the
Stopwatch Minute Hand
to 0.
Holding down either button will move the second hand at high speed, until you
release the button.
The
Stopwatch Minute Hand
is synchronized with the
Stopwatch Second Hand
.
After all of the hands are the way you want, push the Crown back in.
Important!
Timekeeping stops while the crown is pulled out. Correct the current time setting
after performing the above operation.
Using the Stopwatch
Important!
Do not operate the stopwatch with the crown pulled out.
Note
An elapsed time operation will stop automatically at the end of 10 minutes.
The stopwatch measures elapsed time in 1-second increments up to 9minutes,
59seconds.
Elapsed time
A
A A A B
Start Stop Resume Stop Reset
Split time
A
B B A B
Start Split Split release Stop Reset
Two finishes
A
B A B B
Start Split
First runner
finishes.
Display time of
first runner.
Stop
Second runner
finishes.
Split release
Display time of
second runner.