Specifications
— 2 —
Current consumption:
NOTES:
1. Be sure to measure after adjustment referring to 6.ADJUSTMENT of this manual.
2. When measuring these current, be sure to use suitable range analog ammeter.
Operation Mode Input Current consumption
Main menu of OPERATION Rechargeable Battery : ≤280mA
CHECK in this manual 4.0V ± 0.1V
5. POWER CONTROL of Rechargeable Battery : ≤600mA
OPERATION CHECK of this manual 4.0V ± 0.1V
5. POWER CONTROL of AC Adapter : 5.0V ± 0.1V ≤600mA
OPERATION CHECK of this manual
Power/OFF Rechargeable Battery : ≤1.4mA (E-100)
4.0V ± 0.1V ≤1.8mA (E-105)
Power/OFF Lithium battery for Back-up ≤950µA (E-100)
3.0V ± 0.1V ≤1.3mA (E-105)
Length (L) Angle (A)
L ≤ 32 cm A ≤ ±15˚
MAIN Battery = Rechargeable Battery (Lithium-lon battery)
Voltage Detectors: (Refer to CIRCUIT EXPLANATION of this manual.) :
VDET1B : 3.4 V ± 1% (Low battery message Rechargeable battery)
VDET2 : 3.2 V ± 1% (Forced power off)
VDETS : 2.7 V ± 1% (Low battery message for Back-up battery)
Operation Condition for Data transfer using IrDA :
A
E-100
E-105
E-100
E-105
L