7.OPERATION CHECK
7-1.Preparation
1.E-100/ -105 5.Cradle
2.Compact Flash memory card 6.PC installed Windows CE Services 2.2
3.Rechargeable battery pack
7. Diagnostic program (Diag. exe)
4.AC adapter (AD-C50200)
Notes: Be sure to make back-up copies of all important data in E-100/-105 because this
check make these data deleted.
Diagnostic program (Diag. exe) exist in SOFT holder of CD-ROM for Service informa-
tion Disk.
After all checks are finished, perform Full Reset.
If not performed, this program remains to exist in RAM of E-100/ -105.
The program file names (Diag.exe/ CASIO_JX500diag.exe) are the same names as
ones of E-10/-15. Take care not to confuse.
To enter operation check, perform the following procedures after Initial Setup.
7-2.How to install the diagnostic program to E-100/-105
There are two ways to install the diagnostic program to E-100/-105.
7-2-1.The way of using Compact Flash memory card
Using Compact Flash memory card saved this program, you can perform the operation check without
PC.
At first, It is necessary to save the diagnostic program to Compact Flash memory card.
1.Set a Compact Flash memory card to E-100/-105.
2.Connect a cradle and PC installed Windows CE Services 2.2.
3.Set this E-100/-105 to this cradle.
4.E-100/-105 will be automatically turned on, and then the communication with PC will start.
5.After this communication, Mobile Devices window will be automatically opened.
6.Five folder will be made in Guest of Mobile Devices window also.
7.Click the Storage Card folder in Guest.
8.Make a new folder in this folder. Make its folder name jx520diag precisely.
9.Make a new folder in this jx530diag folder. Make its folder name casioconfidential precisely.
10.Enter the Diag.exe program file described above in this casioconfidential folder.
(Directory: Storage Card> jx530diag> casioconfidential> Diag.exe)
11.Finish to communicate with PC.