2-11-2. Solution to abnormality of master terminal
When the satellite terminals cannot receive any information from the master terminal, the
master terminal shows the error message on the window and prints out the receipt with
terminal IDs that failed to communicate the data.
Receipt image
REG 12-31-2002 11:59 AM 001234 Header
Communication Error Fixed flash message
MC#01 XXXX Machine ID, Error code
MC#03 XXXX Machine ID, Error code
The error message and receipt will appear whenever the sign-in is failed. If you cannot
solve the inline data communication problem, program the system connection again,
and remove the uncommunicative terminal.
2-11-3. Solution to abnormality of satellite terminal
When the satellite terminal cannot receive any information from the main terminal, the
default CLOCK-IN/OUT information remain.
In this case, only manager can sign on.
When the satellite terminal could receive the CLOCK-IN/OUT information from the
master terminal a few times, but failed to receive after then, the CLOCK-IN/OUT
information in all the satellite terminals leaves the last received information. In such
case, the last received information control employees sign on/off. (Manager can
always sign on.)
2-11-4. Sign on compulsory
When the satellite terminal cannot receive the information in spite of normal CLOCK-IN
operation on the master terminal, an employee may not sign on for some reason.
In such case, the manager needs the following operation.
1. Sign on by the manager (normal sign on operation.)
2. 99 xxxx <CLK#> (xxxx: the secret code of the corresponding employee, 4-digit.)
3. Sign off by the manager or the corresponding employee (normal sign off operation.)
Note:
When the error message appeared under the employees CLOCK-IN operation, manager
should operate above steps.
REG 10-10-01 11:59 AM 001234
Harrison
CLOCK-IN 11:59 AM
JOB Dish Washier
E177 Time&Attendance Data
Communication Error.
Please Call Manager.
0.00
Please sign on.