Notes:
1. OBROpen func
tion also can be used to specify each "Enable" or "Disable" status for
scanning individual symbology. The settings with OBROpen funct
ion have the
priority over the settings with OBRSetScanningCode func
tion. This means that the
settings on individual symbology performed with OBRSetScanningCode funct
ion
are reset to the settings with OBROpen func
tion when OBROpen function is called.
2. IT-600, DT-X7, DT-X11, DT-X30, IT-800, IT-300, and DT-X8 support the symbology.
3. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support that the
settings for reading Industrial 2of5 and IATA symbologies are to be concurrently made
enabled. If it is done wrongly, all other settings for reading other symbologies are
disabled and a parameter error is returned.
4. Individual settings for reading RSS-14, RSS-14 Stacked, and RSS Expanded, and RSS
Expanded Stacked symbologies are not supported. If setting for reading a standard RSS
symbology is set enabled, all the corresponded RSS Stacked symbologies are
automatically set enabled for reading.
5. The RSS symbologies change its name to "GS1 DataBar".
RSS-14 → GS1 DataBar Omnidirectional
RSS Limited → GS1 DataBar Limited
RSS Expanded → GS1 DataBar Expanded
RSS-14 Stacked → GS1 DataBar Stacked
RSS Expanded Stacked → GS1 DataBar Expanded Stacked
6. The setting for reading Code128 symbology will make also reading the GS1-128
symbology (previously named as EAN128 symbology) possible.