dwMode
This parameter is for setting "Enable" or "Disable" for each bar code symbology which is
specified with a sum of the values in logical OR operation selected in the list below. These
are designated using the following OR (logical add) values. If zero "0" is specified,
scanning condition is set enabled with the current settings. Or, if any value other than 0 is
set, first all the settings will be changed to the default settings, and then settings with the
specified values will become reflected. See note 5.
OBR_CD39 : Code39 symbology enabled
OBR_NW_7 : NW-7 symbology enabled
OBR_WPCA : WPC Addon symbology enabled
OBR_WPC : WPC symbology enabled
OBR_UPEA : UPC-E Addon symbology enabled
OBR_UPE : UPC-E symbology enabled
OBR_IDF : Industrial 2of5 symbology enabled
OBR_ITF : Interleaved 2of5 symbology enabled
OBR_CD93 : Code93 symbology enabled
OBR_CD128 : Code128 symbology enabled (note 7)
OBR_MSI : MSI symbology enabled
OBR_IATA : IATA symbology enabled
OBR_RSS14 : RSS-14 symbology enabled (notes 1 and 6)
OBR_RSSLTD : RSS Limited symbology enabled (notes 1 and 6)
OBR_RSSEXP : RSS Expanded symbology enabled (notes 1 and 6)
OBR_RSS14S : RSS-14 stacked symbology enabled (notes 4 and 6)
OBR_RSSEXPS : RSS Expanded stacked symbology enabled (notes 4 and 6)
OBR_ALL : All the symbologies enabled
OBR_CHK_ON : Check digit calculation enabled for all the symbologies (note 2)
OBR_OUT_ON : Check character output enabled for all the symbologies (note 3)
Notes:
1. Available only with symbologies that support check digit calculation.
2. Available only with symbologies that support check character output.
3. IT-600 and DT-X11 support the check character output.
4. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support that the
settings for reading Industrial 2of5 and IATA symbologies are to be concurrently made
enabled. If it is done wrongly, all other settings for reading other symbologies are
disabled and a parameter error is returned.
5. Individual settings for reading RSS-14, RSS-14 Stacked, RSS Expanded, and RSS
Expanded Stacked symbologies are not supported. If setting for reading a standard RSS
symbology is set enabled, all the corresponded RSS Stacked symbologies are
automatically set enabled for reading the symbologies.
6. The RSS symbologies change its name to "GS1 DataBar".
RSS-14 GS1 DataBar Omnidirectional
RSS Limited GS1 DataBar Limited
RSS Expanded GS1 DataBar Expanded
RSS-14 Stacked GS1 DataBar Stacked
RSS Expanded Stacked GS1 DataBar Expanded Stacked