User manual
183
Table 5.35 Decode Customize parameters (DT-X11, IT-600, DT-X7, DT-X30, IT-800, IT-300,
DT-X8) (Note 7)
0 No correction.
1 Correct black bar thin.
2 Correct black bar thin noticeably.
3 Correct white bar thin.
4 Correct white bar thin noticeably.
5 Correct black bar thick.
6 Correct black bar thick noticeably.
7 Correct white bar thick.
BARWIDTH Specify a correctness of bar’s
thickness or thinness.
8 Correct white bar thick noticeably.
0Large
1Medium
2 Small
MARGINCHECK Specify a threshold for right
and left margins.
3Minimum
Table 5.36 Learning Decode option parameters (DT-X11, IT-600, DT-X7, DT-X30, IT-800,
IT-300, DT-X8) (Note 7)
0Disable
LEARNING Specify "Enable" or "Disable" for
the learning decode function.
1Enable
Notes:
1. To set multiple symbologies effect for reading, specify a sum of the values in logical OR for each
symbology you wish to scan.
2. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support the following.
2-1. Reading UPC-B and UPC-B Addon symbologies.
2-2. Setting concurrently for reading both Industrial 2of5 and IATA symbologies. If it is done
mistakenly, setting for reading Industrial 2of5 becomes enabled, but, setting for the other
symbology becomes disabled.
2-3. Individual settings for reading RSS-14, RSS Expanded, RSS-14 Stacked, and RSS Expanded
Stacked symbologies. If the standard RSS symbology is set enabled, all the corresponded
Stacked symbologies are automatically set enabled.
3. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support the outputs of
Code128 and EAN-128 symbologies without ASCII conversion, and the FNC2 joint output to be
disabled.
4. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support
"OBR_CHKDOFF (Without check digit calculation)" and "OBR_CDMSEV (With 2-digit check
digit calculation)" to be set in the respective parameters.
5. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support
"OBR_CHKDOFF (Without check digit calculation)" to be set in byCheckDigit parameter.
6. To concurrently specify multiple output conditions effect, specify a sum of the values for each
condition you wish to set effect. However, the concurrent setting of "EAN-128 without Full
ASCII conversion" with any one of "EAN-128 with ID code", "Convert Fnc to GS and output
EAN-128", "Code128 and EAN-128 FNC2 combined", or "Code128 and EAN-128 FNC4
expansion ASCII conversion" effect is not supported. If it is done wrongly, the setting on
"EAN-128 without Full ASCII conversion" is preferentially set enabled.
7. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support the parameter.
8. Setting up the scan width control function (
OBRSetSwingAngle function) in one of four modes
while th
e setting gain (OBRSetGainControl function) is set up in Auto mode may cause a