byMinLength
This parameter is for specifying the minimum number of digits. It is fixed to 14 digits and
cannot be changed. Always specify 14.
byMaxLength
This parameter is for specifying the maximum number of digits. It is fixed to 14 digits and
cannot be changed. Always specify 14.
byOutFormat
This parameter is for specify output format selecting either of the values listed below.
OBR_RS14NORM : Output RSS-14 symbology in standard format.
OBR_RS14AIOF : Output RSS-14 symbology without application identifier and "01" at
the forefront.
byCheckDigit
This parameter is for specifying check digit. Since the check digit with RSS-14 symbology
is kept enabled at all times, always specify OBR_CHKDON in this parameter.
byCheckChar
This parameter is for specifying check character output. Since the check character output
with RSS-14 symbology is kept enabled at all times, always specify OBR_CHKKON in
this parameter.
Return Values
OBR_OK : Normal end
OBR_PRM : Parameter error
OBR_PON : Open already
OBR_NOT_DEVICE : Scanner driver error. In the Device Emulator, this value is not returned.
FUNCTION_UNSUPPORT : Unsupported error
Notes:
1. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support that
setting for reading RSS-14 symbology only is individually set enabled. If it is set enabled,
setting for reading RSS-14 Stacked symbology is also set enabled automatically.
2. RSS-14 symbology changes its symbology name to "GS1 DataBar Omnidirectional".