User manual

124
Notes:
1. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support that
Code128 and EAN-128 symbologies without ASCII conversion are output. If one of the
values with "Without ASCII conversion" is specified in byOutputFormat parameter,
Specify always set as with ASCII conversion.
2. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support that
"Output Code128 or EAN-128 with FNC2 combined" is disabled in byOutFormat
parameter. It is always set enabled.
3. IT-600M30U, IT-600M30UC, DT-X7M10U, and IT-300E-35E do not support
"OBR_CHKDOFF (Without check digit calculation)". Specify always "OBR_CHKDON
(With check digit calculation)" in byCheckDigit parameter.
4. The maximum number of digits for both CodeA and CodeB symbologies are 64 and 98
respectively for CodeC symbology.
5. EAN128 changes its symbology name to GS1-128.
6. Code128 should be set as with check digit. If you set this setting without check digit by
special reason, please check scanning operation carefully because there is possibility to
mis-reading by printed quality or some condition.