Specifications
71
2.7.3. Power OFF Factors
The following are the power OFF factors.
• The Power key is pressed while the power is on.
• Neither key input, disk access, card access, nor communication is performed within a preset
time period.
• Output voltage from the battery pack is low (VDET2, VDET3) (see note).
• The battery cover lock is open.
• An excess of load on the CF card lowers voltage (VDETCF) (see note).
• Internal temperature in the terminal exceeds over 70 ºC.
Note:
Warning message will appear a next time when the power is turned on.
Power OFF Time
When either VDET2, BCVR, VDETCF or VDET3 occurs, the power will be turned off after the
respective time periods elapse.
Table. 2.59
VDET2
BCVR
VDETCF
Turning off (resume OFF) the power after 200 milliseconds.
VDET3 Forced to turn off the power after 500 milliseconds.