Setting Specific Operation Unique to Code128 Symbology
The terminal supports specific operations unique to the Code128 symbology that are initiated
when certain conditions are met at a time of scanning a symbol of the Code128 symbology.
Table. 2.41
Symbology Condition Performance
At time of scanning a symbol of Code128
that includes the FNC2 function character.
Scanned symbol data including the FNC2
function character is temporarily stored in the
scanner until when a next symbol is scanned.
The stored data is automatically added at the
forefront of the subsequent scanned symbol data
to be output. (See note below.)
Code128
At time of scanning a symbol of Code128
symbology that includes the FNC4
function character(s).
The value “128” is added automatically to a data
character in ASCII of scanned symbol located
next to the FNC4 function character. If two
sequentially laid FNC4 function characters in a
symbol are scanned, either other group of two
sequentially laid FNC4 function characters
within the same symbol are read, or “128” is
added automatically to each subsequent ASCII
character data laid next to the two FNC4
function characters until the last.
Notes:
The size of combined symbol data including the FNC2 function character is limited to 98
characters (maximum). If the size of any combined symbol data exceeds the maximum number of
characters, the previous combined symbol data that have been scanned right before the exceeded
combined symbol data are output.