User Manual
E-25
Multiple Battery Charger
AD-S12500A
• You can connect up to three Multiple Battery Chargers.
DT-X400 Charging status LED display
Orange: Charging
Green: Charging complete
Red: Standby due to battery pack error or because the ambient temperature is
outside the charging temperature range.
(Charging begins when the temperature returns to the charging temperature
range.)
Orange fl ashing: Charging (DT-X400 cannot start up because the charge remaining in the
battery pack is too low. Wait until the charging status LED stops fl ashing
and lights orange.)
Dual Battery Charger
AD-S12500A
• You can connect up to three Dual Battery Chargers.
Charging status LED display for the four-bay battery charger
Red: Charging
Green: Charging complete
Red/green alternate fl ashing: Standby because the battery pack is faulty, is installed
incorrectly or is outside the charging temperature range
(Charging begins when temperature returns to the charging
temperature range)
Precautions for Use
• Even if the battery in the DT-X400 is already fully charged, charging will begin when
you set the DT-X400 in the cradle. It may take several minutes for the fully charged
status to be indicated.
• Take care not to trap objects such as the strap in the cradle.
• The power/data communication terminal and the battery pack power contacts
should be cleaned periodically using an implement such as a dry cotton bud.
Soiling or dust buildup could cause connection problems.