Specifications
59
0 0: No correction
1 1: Thin black bar
2 2: Thin black bar (or
thicken black bar)
3 3: Thin white bar
BARWIDTH Setting correction value
of thickness of bars
4
0
4: Thin white bar (or
thicken white bar)
0 0: Maximum
1 1: Middle
2 2: Narrow
Decode Customize
Option
MARGINCHECK Setting threshold values
for right and left margins
3
0
3: Minimum
00: Disable
Learning
Decode
Option
LEARINING Setting learning mode
1
0
1: Enable
Notes:
1. To set up multiple bar code symbologies effect, specify a sum of the symbology values you
wish to scan.
2. To set up multiple output methods effect, specify a sum of each value of the output methods
you wish to set. However, if you set “EAN128 without Full ASCII conversion”, “EAN128 with
code ID attached” and “EAN128 Fnc → GS conversion” effect at the same time, “EAN128
without Full ASCII conversion” has the priority over the other settings. Thus, the settings are
disabled.
3. Since Gun-trigger key is not integrated in the terminal, the key value is ignored.
4. A.I. is the abbreviation of Application Identifier which is attached at the forefront of bar code
of RSS-14, RSS-Limited, and RSS-14 Stacked symbologies.
5. The RSS symbologies change its name to “GS1 DataBar”.
RSS-14 → GS1 DataBar Omnidirectional
RSS Limited → GS1 DataBar Limited
RSS Expanded → GS1 DataBar Expanded
RSS-14 Stacked → GS1 DataBar Stacked
RSS Expanded Stacked → GS1 DataBar Expanded Stacked
6. EAN-128 symbology changes its name to “GS1-128”.
The functions of the Laser Scanner Library relevant to the Configuration File are as follows.
OBRSaveConfigFile
: Saves all settings for the scanner driver into the configuration file.
OBRLoadConfigFile
: Retrieves and then loads the configuration file into the scanner
driver.
OBRSetDefaultSymbology
: Sets up default status of the Laser Scanner driver.