Specifications

52
Configuration File
The various setting values can be stored in a file and resumed. The setting file storage location and
its name are “\Documents and Settings\System Settings\OBRDRV.ini”. If there is no such the
setting file, the default values are used to initiate the scanning.
Table 2.46
Symbol
ogy
Parameter Description Range Default Setting
1 1: Enable Code39
22: Enable NW-7
4 4: Enable WPC Addon
88: Enable WPC
16 16: Enable UPC-E Addon
32 32: Enable UPC-E
64 64: Enable IDF
128 128: Enable ITF
256 256: Enable Code93
512 512: Enable Code128
1024 1024: Enable MSI
2048 2048: Enable IATA
4096 4096: Enable RSS-14 (note
5)
8192 8192: Enable RSS Limited
(note 5)
16384 16384: Enable RSS Expanded
(note 5)
32768 32768 Enable RSS-14
Stacked (note 5)
Readable Bar Code
READCODE Enable or disable
scanning the
symbologies.
(note 1)
65536
131071
65536 Enable RSS Expanded
Stacked (note 5)
CODE39_MIN Valid minimum digits 2 2
CODE39_MAX Valid maximum digits 52 52
0 0: Output Code39 bar code
with start and stop
characters.
1 1: Output Code39 bar code
without start and stop
characters.
2 2: Output Code39 bar code
after Full ASCII conversion
and with start and stop
characters.
CODE 39 Option
CODE39_OUTFORMAT Output format
3
0
3: Output Code39 bar code
after Full ASCII conversion
and without start and stop
characters.
Continue.