Specifications

80
3.3.8 Imager’s APO
This function will shut down the power to the imager automatically if the imager has not been
used for a while. After activating the APO (Automatic Power OFF) function, the imager’s power
can be turned on again if one of the following functions is invoked. The time period of the APO
function can be set up in the range of 0 to 1,800 seconds. Specifying “0” will disable it. The power
consumption by the imager can be curbed while the APO function is activating. However, note
that it takes about 30 milliseconds to put the power back on.
Scan a symbol.
Assist scanning symbol.
Scan an OCR font.
Capture an image.
Index a signature.
Stream display.
Adjust CMOS imager.
3.3.9 Scan Result Notification
The notification of the read completion of a symbol can be posted using one of the following two
integrated devices. The buzzer sound level can be set up at the Control Panel.
Table 3.52
Device Setting Read succeeded Read failed
Read terminated
(release the Trigger key)
Remark
Mode 1 Lit in green Lit in red None Default
Mode 2 Lit in green None None
LED
Invalid None None None
Valid Sound None None Default
Buzzer
Invalid None None None