3.8.5 Power OFF Factors
The following are the power OFF factors.
• The Power key is pressed while the power is on.
• Neither key input, touching on the touch panel, disk access, card access, nor communication is
performed within a preset time period.
• Output voltage from the battery pack is low (VDET2, VDET3) (see note).
• The battery cover lock is open. (BCVR) (see note)
• An excess of load on the CF card lowers voltage (VDETCF) (see note).
Note:
Warning message will appear a next time when the power is turned on.
Power OFF Time
When either VDET2, BCVR, VDETCF or VDET3 occurs, the power will be turned off after its
time period listed in the following table elapses.
Table 3.68
VDET2
BCVR
VDETCF
Turning off (resume OFF) the power after 200 milliseconds.
VDET3 Forced to turn off the power after 500 microseconds.