Specifications
— 10 —
DIAGNOSTIC PROGRAM
To enter the diagnostic program, proceed as follows;
1 : Open the battery cover and slide the main switch to the arrow side.
2 : Press ON while shorting the pads CP39 and CP57.
RESET
MAIN SWITCH
CP39
CP57
Bottom View
STEP OPERATION DISPLAY NOTE
Enter the
diagnostics
Press ON while shorting
the pads CP39 and CP57.
///// SELF TEST PROG /////
PRESS OK KEY
QUIT BY OFF KEY
CASIO JULY 1995
Main menu OK ////////// TEST MENU //////////
1 DISPLAY
2 MEMORY
3 KEY & TIME
4 BUZZER
5 I / F
6 CONTRAST
7 RESET
DIsplay
Check
1 ////////// DISPLAY //////////
1 DISPLAY
2 FRAME FREQ.
1 No color, no displa
y
OK Oran
g
e color is displa
y
ed
OK Green color is displa
y
ed
OK Blue color is displa
y
ed
OK Checkers are displa
y
ed
OK Reverse checkers are displa
y
ed
OK Frame is displa
y
ed
OK Dots at the 4 corners are
displa
y
ed
OK Vertical 4 colors are displa
y
ed
OK Horizontal 4 colors are displa
y
ed
OK ////////// TEST MENU //////////
1 DISPLAY
2 MEMORY
3 KEY & TIME
4 BUZZER
5 I / F
6 CONTRAST
7 RESET