User Manual

Chapter 12: Program Application  218Chapter 12: Program Application  218
RclVWin Misc - Graph&Table(2)
Syntax: RclVWin{<variable name> ; <folder name\
file name>}
Function: Recalls View Window values, which were
previously saved under the specified name.
Description: A folder path can be specified only up to
one level.
Receive38k I/O - Communication
Syntax: Receive38k<variable name>
Function: Receives Data Logger data.
Description:
The OpenComPort38k command must be executed
before this command is executed.
The CloseComPort38k command must be
executed after this command is executed.
For details about using this command, see the user
documentation that comes with the EA-200.
Note that you need to replace all instances of the
Receive command in the examples provided in
the EA-200 user documentation with the command
Receive38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
Rename Misc - Variable
Syntax: Rename<current variable name>, <new
variable name>
Function: Renames a variable.
Return Ctrl - Control
Syntax: Return{<variable>}
Function 1 (Main Program): Terminates program
execution.
Function 2 (Subroutine Program): Returns from a
subroutine.
Tip
The Return command can be executed during an If, For,
Do, While, or Switch process.
Appending a <variable> to the Return command in
the Main application and executing the command will
cause the variable to be displayed when the program is
complete.
S
Scatter Misc - Statistics(1) - Graph
Function: Used as a StatGraph command argument
to specify an option. See StatGraph.
Send38k I/O - Communication
Syntax: Send38k<variable name>
Function: Sends Data Logger data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
For details about using this command, see the user
documentation that comes with the EA-200.
Note that you need to replace all instances of the
Send command in the examples provided in the
EA-200 user documentation with the command
Send38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
<variable name> must be a variable that contains
a real number or a list. Anything else results in an
error.
SendVar38k I/O - Communication
Syntax: SendVar38k<variable name>
Function: Sends variable names and variable
contents.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
SeqSelOff Misc - Sequence
Syntax: SeqSelOff{
a
n
+1
; a
n
+2
; b
n
+1
; b
n
+2
; c
n
+1
; c
n
+2
;
a
n
E ; b
n
E ; c
n
E}
Function: Deselects the specified sequence
expression. Specifying “
a
n
E”, “b
n
E”, or “c
n
E” as the
argument activates [Explicit]. Specifying any other
argument activates [Recursive].
SeqSelOn Misc - Sequence
Syntax: SeqSelOn{
a
n
+1
; a
n
+2
; b
n
+1
; b
n
+2
; c
n
+1
; c
n
+2
;
a
n
E ; b
n
E ; c
n
E}
Function: Selects the specified sequence expression.
Specifying “
a
n
E”, “b
n
E”, or “c
n
E” as the argument
activates [Explicit]. Specifying any other argument
activates [Recursive].
SeqType Misc - Sequence
Syntax: SeqType{"
n" ; "a
n
+1
a
0
" ; "a
n
+1
a
1
" ; "a
n
+2
a
0
" ;
"a
n
+2
a
1
"}
Function: Specifies the recursion type.
Description: Specifying “
n” as the argument activates
[Explicit]. Specifying any other argument activates
[Recursive].