Specifications

— 12 —
Message
TRANSMIT
ERROR!
RECEIVE
ERROR!
MEMORY
FULL!
Meaning
Problem with cable connection or param-
eter setting during data communications.
Problem with cable connection or param-
eter setting during data communications.
Memory of receiving unit became full
during program data communications.
Countermeasure
Check cable connection.
Check to see that the parameters of the
sending unit and receiving unit are
identical.
Check cable connection.
Check to see that the parameters of the
sending unit and receiving unit are
identical.
Delete some data stored in the receiv-
ing unit and try again.
DISPLAY
(OFF)
Frame is displayed
No color, no display
Red dots are displayed
Green dots are displayed
NOTE
Reset
TEST mode menu
Check for display
Check for display
Check for display
Check for display
8.OPERATION CHECK
RESET
ALL MEMORIES !
✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽
✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽
RUN / COMP
ZM PLT LIN CLS
G-type
Angle
Display
M-D/Cpy
: REC/CON
: Deg
: Nrm1
: M-Disp
LX392 TEST MODE
1. LCD
2. KEY
3. RAM
4. ROM
5. DET
6. TRS
7. Cnt
0. Rst
OPERATION
Use a thin and pointed object to
press the RESET button on the
back of the unit.
F1
SHIFT
AC/ON
Press
F6
ab/c
AC/ON
keys at same
time.
1
EXE
EXE
EXE
STEP
1
2
3
4
5
6
7
8
9
✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽
✽✽
✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽✽
RESET
RESET
ALL MEMORIES?
RESET ALLYES NO