Description Multiple validation (If “No”, only one validation printing is possible., Description Restriction (to 0, 5) on last digit for amount tendered. Choice Program code No = 0 Yes = 1 D12 : Significant number (0 ~ 9) Allowable number of validation printing (“0” means no limitation) *1 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 D11 : No = 0 Yes = 1 Force validation operation.
Key function/machine feature (P3) <+ (PLUS)>, <- (MINUS)>, Description Multiple validation (If “No”, only one validation printing is possible.) *1 Choice Program code Yes = 0 No = 4 D11 : : Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 No = 0 Yes = 1 Allow credit balance.
Description Choice Program code : No = 0 Yes = 1 Restriction (to 0, 5) on last digit for amount tendered. D12 ; Always “0” D11 a No = 0 Yes = 1 b No = 0 Yes = 4 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Multiple validation (If “No,” only one validation is possible.) *1 : (a+b) D10 : (a+b+c) D9 ; Always “0” Key attribution D8 Open cash drawer.
Key function/machine feature (P3) Description Multiple validation (If “No”, only one validation printing is possible.) Choice Program code Yes = 0 No = 4 D11 : ; Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 Key attribution Print when registered.
, Description *1 Multiple validation (If “No”, only one validation printing is possible.) Choice Program code Yes = 0 No = 4 D11 : ; Always “0” D10 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : (a+b+c) D9 :: Taxable status: See below. D8 D7 Significant number Rounding: Round off = 0, cut off = 1, round up = 2 Allow key operation after .
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ;; Always “0” D8 D7 No = 0 Yes = 2 Prohibit manual entry. Significant number Rounding: Round off = 0, cut off = 1, round up = 2 : D6 : D5 ;;;; Always “0” D4 D3 D2 D1 Description Choice Disable operation in RF/REG– mode.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 : Significant number Line number of auto-back feed before printing (0 ~ 9) D7 ;;;;;; Always “0” D6 D5 D4 D3 D2 D1 , Description Choice Disable operation in RF/REG– mode.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Significant number Input method: Allow replacement = 0, Prohibit replacement = 1, Add enter value = 2 : D7 ;;;;;; Always “0” Program 3 D6 D5 D4 D3 D2 D1 Description Choice Significant numbers Secret code (0000 ~ 9999) Enable operation in X1 mode.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Define amount symbol. (0, 1 ~ 4) (“0” means local currency symbol.) Significant number Define foreign currency totalizer. (0, 1 ~ 4) (“0” treats as “1”.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 Force slip batch printing from the beginning of the transaction. If “No”, controlled by general function.) a No = 0 Yes = 1 Print issuing time (only effective when slip is printed from the beginning of the transaction).
Key function/machine feature (P3) Description Choice Program code Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Exempt tax 1 a Yes = 0 No = 1 ; Exempt tax 2 b Yes = 0 No = 2 : Exempt tax 3 c Yes = 0 No = 4 : (a+b+c) D9 • U.S.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 a Release table number compulsory. b Yes = 0 No = 2 Release check number compulsory. c Yes = 0 No = 4 Release credit balance error. (If “Yes,” you can finalize the transaction even if the subtotal is negative.
Key function/machine feature (P3) Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 The reviewed range of item: 2=0 1=1 Display “Check number”, “Table number”, and “Customer number”.
Description Choice Allowable number of validation printing *1 (“0” means no limitation) Program code Significant number (0 ~9) Force validation operation *1 No = 0 Yes = 1 Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 : D11 : D10 : (a+b+c) D9 ;; Always “0” D8 D7 Include add-on tax. Print tray total when is pressed.
Key function/machine feature (P3) , , , , Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode.
, Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ; Always “0” D8 : No = 0 Yes = 1 Enable auto check assignment D7 ;;;;;; Always “0” Program 3 D6 D5 D4 D3 D2 D1 Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode.
Key function/machine feature (P3) , Description Choice Program code Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Exempt tax 1 a Yes = 0 No = 1 ; Exempt tax 2 b Yes = 0 No = 2 : Exempt tax 3 c Yes = 0 No = 4 : (a+b+c) D9 • U.S.
Description Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode. b No = 0 Yes = 2 Disable operation in REG1 mode. c No = 0 Yes = 4 Program code : (a+b+c) D9 ;;;;;;; Always “0” D8 D7 D6 D5 D4 D3 D2 A range of item correction: : 2=0 1=1 1From the beginning of this transaction 2Current receipt only D1 Choice Disable operation in RF/REG– mode. a No = 0 Yes = 1 Disable operation in REG2 mode.
Key function/machine feature (P3) Clerk program Secret number, drawer, check number programming Programming procedure To a new (not sequencial) clerk To the next clerk 6 3s 6 : : 07s6 : : ~ : : 6 a 6 s PGM D12 D11 ~ D2 D1 Record No. Mode switch Data Description Choice Program code :::::: Significant numbers Check number for clerk interrupt Assigning drawer number • 00 ~ 02 for CE-6000/6100, TK-6000/6500, CE-T300 • 00 ~ 04 for CE-7000, TK-7000/7500, TK-T500 ("00" means drawer 1.
Clerk other programmings Programming procedure (individual) To a new (not sequencial) clerk To the next clerk PGM 6 3s 6 : : 07s 6 : : s 6 : ~ : a 6 s Record No. Mode switch Program data Address code Programming procedure (by range) PGM 6 3s 6 99000007s 6 : : s 6 Address code Mode switch Ends “the last record”. Program 3 Starts “0001”.
Key function/machine feature (P3) Address code 68 (Commission rate) Description Choice Commission rate 1 (integer: 00 ~ 99) Significant numbers Commission rate 1 (decimal: 00 ~ 99) Significant numbers Commission rate 2 (integer: 00 ~ 99) Significant numbers Commission rate 2 (decimal: 00 ~ 99) Significant numbers Program code :: D8 D7 :: D6 D5 :: D4 D3 :: D2 D1 Address code 69 (Table number range) Description Choice Minimum range for table range (1 ~ 999999) (“0” means no programming.
Other programs Time range programming To a new (not sequencial) record Programming procedure To the next record PGM 6 3s 6 : : 09s6 : ~ : 6 a 6 s Record No.
Key function/machine feature (P3) Tax table programming Programming procedure PGM Mode switch 8 3s 8 ::::s 8 (for the U.S., Singapore) Tax table 1 = 0125 Tax table 2 = 0225 Tax table 3 = 0325 { (for Canada) Tax table 1 = Tax table 2 = Tax table 3 = Tax table 4 = { 0125 0225 0325 0425 (for other area) Tax table 1 = Tax table 2 = : = Tax table 10 = { 0125 0225 : 1025 : : ^: : : : a Tax rate (4-digit for integer + 4-digit for decimal) ::::a Tax table maximum value (“0” means unlimited).
Example 1: Add-on rate tax Tax rate (2-digit for integer + 4-digit for decimal) ............................... Tax table maximum value ("0" means unlimited). ............................... Rounding/tax table system code ........................................................... Sum of a cyclic pattern ......................................................................... Number of values in each cyclic pattern ...............................................
Key function/machine feature (P3) Example 2: U.S. tax table without rate setting TAX (6%) $ .00 .01 .02 .03 .04 .05 .06 .07 .08 Price range Min. break point Max. break point $ .01 $ .10 .11 .24 .25 .41 .42 .58 .59 .74 .75 .91 .92 1.08 1.09 1.24 1.25 1.41 Max. break point Difference Upper Lower 10 – 0 = 10 24 – 10 = 14 41 – 24 = 17 58 – 41 = 17 74 – 58 = 16 91 – 74 = 17 108 – 91 = 17 124 – 108 = 16 141 – 124 = 17 17 Tax rate (2-digit for integer + 4-digit for decimal) ...............................
Example 3: U.S. tax table with rate setting Price range Min. break point Max. break point $ .01 $ .07 .08 .21 .22 .35 .36 .49 .50 .64 .65 .78 .79 .92 .93 1.07 1.08 1.21 1.22 1.35 1.36 1.49 1.50 1.64 1.65 1.78 1.79 1.92 1.93 2.07 Max.
Key function/machine feature (P3) Example 4: Add-in rate tax Tax rate (2-digit for integer + 4-digit for decimal) ............................... 10.00 % Rounding/tax table system code. .......................................................... 0003 (Cut off) PGM Mode switch 3s 8 ::::s 8 10a 8 0a 8 0003a 8 s Tax table No.
Set menu programming Programming procedure To a new (not sequencial) record To the next record a Maximum 15 items can be set. PGM 6 3s 6 : : 28s 6 B6 PRICE SHIFT Mode switch Record No. MENU FlatSHIFT B 6 B PLU {: ~ 6s } : 6+ PLU code Rec #: within 4 digits Random code: within 6 digits Program 3 Batch X/Z report programming To a new (not sequencial) record Programming procedure To the next record a 1st to 11th field PGM 6 3s 6 : : 29s 6 : ~ : 6 a 6 s Program data Record No.
Key function/machine feature (P3) Hourly item (time range) programming Programming procedure To a new (not sequencial) record To the next record PGM 6 3s 6 : : 84s 6 : ~ : 6a 6 s Mode switch Program data Record No.
Arrangement programming Programming procedure ** PGM * 6 3s 6 : ~ : 38s 6 A6 : ~ : a 6 Arrangement table No. (up to 6 digits) Record No. (up to 4 digits) Mode switch * 6 : ~: 6A6s * The same A should be pressed. ** Vacant record search: If you want to set an arrangement program to a new record, “vacant record search” is possible. (enter 0000 instead of entering a record No.
Key function/machine feature (P3) Mix & match programming Programming procedure To a new (not sequencial) record To the next record PGM 6 3s 6 : : 51s6 Mode switch Record No.
Scheduler programming Programming procedure PGM 6 3s 6 : : 62s 6 : ~ : 6 a 6 Record No. Mode switch To new record Program data 1 To the next record 6 : ~ : 6 a 6 : ~ : 6a 6s Description Program data 3 Choice Designate clerk by record number (“00” means the first record.
Key function/machine feature (P3) Job command table Description Job No. Group/terminal ID Parameter Default menu sheet number after signing on.
Bottle link table programming Programming procedure To a new (not sequencial) total To the next record PGM 6 3s 6 : : 73s6 Mode switch Record No. PRICE 6B 6 SHIFT 6 MENU B 6 a 6s FlatB PLU 6 + PLU No. 6 : : : : 04a Program 3 6 Record No. (4-digits) Random code (6-digits) Terminal connection table programming Programming procedure PGM To a new record To the next record 6 3s 6 : : 91s 6 : ~ : 6 a6 s Mode switch Record No.
Key function/machine feature (P3) I/O parameter programming Programming procedure To a new record To the next record PGM 6 3s 6 : : 98s 6 : ~ : 6 a6 s Record No. Mode switch Program data Note: Please perform the following procedure after this program. 1. Power off the register, and connect all peripheral devices to COM ports. 2. Power on all peripheral devices. 3. Flag clear the register.
Program data (Address 03: for COM 3 port) Description Choice External printer/slip printer/scale: • External printer (D4D3 = 80, 81): UP-350 = 00, UP-250 = 01 • Slip printer (D4D3 = 70): SP-1300 = 00 Connected device: Scale = 10, Slip printer = 70, External printer (as external printer 1 in printer connection table) = 80, External printer (as external printer 2 in printer connection table) = 81 Program code :: Significant numbers D6 D5 :: Significant numbers D4 D3 : Significant number Baud rate:
Key function/machine feature (P3) Non PLU table programming To a new record To the next record Programming procedure 6 3s 6 : : 40s 6 : ~ : 6 a6 s PGM Program data Record No. Mode switch Program data Description Choice Non PLU type: Program code : Significant number Short version = 0, Long version = 1, Weight (12-digit) version = 7, Weight (13-digit) version = 8 D16 : No = 0 Yes = 1 Price check digit is included in the price field.
Scanning PLU maintenance programming Batch maintenance PLU programming Programming procedure A Proceeds the next vacant record. 63s 6 0070s 6 : ~ : 6a 6 PGM Record No.
Key function/machine feature (P3) Not found PLU maintenance programming Programming procedure A 63s 6 0072s 6 PGM Mode switch PRICE 6 6 : 6 a6B SHIFT { Code Modify OBR B } Scanning NLU B Action code 6 a 6 : ~ : 6a6 Delete 6 { } a Link-# B DEPT Unit price/quantity B *1 6 a 6 : ~ : - 6 a 6 : ~ : 6a 6 Status Character *1 *1 *1 B A 6 : ~ : 6a 6 : ~ : 6 a 6 s *1 Bottle link Mix & match *1 *1 Skip by general function programming address code 33.
Scanning PLU direct maintenance programming Programming procedure A 63s 6 0071s 6 PGM Mode switch 6 : 6 a6B 6 PRICE SHIFT { Action code { Link-# B DEPT } a Scanning NLU B } 6 a 6 : ~ : 6a6 Unit price/quantity *1 6 a 6 : ~ : - 6 a 6 : ~ : 6a 6 *1 Character Status *1 Program 3 6 OBR B Code *1 A 6 : ~ : 6a 6 : ~ : 6 a 6 s Bottle link *1 Mix & match *1 *1 Skip by general function programming address code 32.
Key function/machine feature (P3) Status Description Choice Significant numbers Taxable status: See below. (In case of “00”, follow the linked department taxable status.) Program code :: D6 D5 ; Always “0” D4 Registration status: (In case of “0”, use the linked department status.) Significant number (0 ~ 3) • Prohibit scale registration = 0 • Allow electionic scale registration = 1 • Allow manual and electronic scale registration = 2 Enable 0 unit price.
One touch NLU programming Programming procedure PGM 63s 6 : ~ : 77s 6 Rec No.
Key function/machine feature (P3) Issuing program reading report of program 3 mode Issuing procedure PGM TK-T500 CE-T300 63s 6 s P03......................... Mode switch CHECK Report sample CREDIT2 CE-7000, TK-7000/7500 TK-6000/6500 PD 0001-02 00000000000000 0002-02 00000000000000 0003-02 P03....................
Character (Program 2) Programming descriptors To other address code To the next address code Programming procedure Rec No. PGM Mode switch File No. 6 2s 6 : ~ : : : s 6 Character 6 a 6 s ☞ See “Entering characters” section.
Character programming (P2) Subdepartment character Up to 12 characters Address code 0103 0203 0303 : 9903 Contents Subdepartment 01 Subdepartment 02 Subdepartment 03 : Subdepartment 99 Initial character SUBDEPT01 SUBDEPT02 SUBDEPT03 : SUBDEPT99 Group character Up to 12 characters Address code 0106 0206 0306 : 9906 Contents Initial character GROUP01 GROUP02 GROUP03 : GROUP99 Group 01 Group 02 Group 03 : Group 99 Clerk character Up to 12 characters Address code 0107 0207 0307 : 9907 Contents Initial
Special character Contents 0123 main currency symbol (2), @ (2), No. (2), split pricing (2), not used (1) training filler (1), training symbol (1), not used (1), sub currency symbol (2) 0223 No. of item sold (2), No.
Character programming (P2) Message Up to 24 characters Address code Contents Initial character YOUR Yours RECEIPT 0132 1st line of logo message 0232 2nd line of logo message THANK 0332 3rd line of logo message CALL 0432 4th line of logo message 0532 1st line of commercial message 0632 2nd line of commercial message 0732 3rd line of commercial message 0832 4th line of commercial message 0932 1st line of bottom message 1032 2nd line of bottom message 1132 3rd line of bottom message
Report header Up to 12 characters Address code Contents Initial character Program 2 FIX 0124 Fixed totalizer report TRANS 0224 Transaction key report PLU 0324 PLU report DEPT 0424 Department report GROUP 0524 Group report CASHIER 0624 Cashier/clerk report 0724 Not used HOURLY 0824 Hourly sales report MONTHLY 0924 Monthly sales report DUB DEPT 1024 Subdepartment report *2 ANALYSIS 1124 Table analysis report *2 OPEN CHK 1224 Open check report *2 SCAN PLU 1324 Scanning PLU *1 *2 HOURLY ITEM 1424 Hourly ite
Character programming (P2) Slip/external printer message Up to 40 characters (Contents are the same as file032.
Error message Up to 16 characters Address code Contents Initial character 0180 0280 0380 : 19180 Error code Mode switch position changed before… Error code : Flash memory format is irregal.
Character programming (P2) Program guidance message Up to 16 characters Address code 0183 0283 0383 : 8583 Contents Range program message 1st line Input start No. message 1st line Input start No. message 2nd line : Initial character Range PGM Input start No.
Programming item/key descriptors Programming procedure Department key/transaction key To another department/transaction key 6 2s 6 PGM Mode switch Characters ☞ See “Entering 6 Department key Transaction key 6 s characters” section. PLU To a new (not sequencial) PLU PGM Mode switch PRICE 6 2s 6 B 6 - PLU No. + 6 Characters a 6 s SHIFT (Rec No,: 4 digits) ☞ See “Entering characters” section.
Character programming (P2) Transaction key Up to 12 characters Function Add check *3 Arrangement Bill copy Bottle return *3 Cancel Cash amount tendered Charge Check endorsement *3 Check print *3 Check tender Clerk number Clerk transfer *3 Coupon Coupon 2 Credit Cube Currency exchange Customer number Decimal point Declaration Department Deposit Discount Eat-in EBT tender Enter Error correct Flat PLU Food stamp status shift Food stamp subtotal Food stamp tender Ketten Bon *3 Loan Lock out unused key Manual ta
Programming item/clerk descriptors by range Programming procedure PGM 6 2s 6 990000 : : s 6 Mode switch Department = 05 PLU/flat-PLU = 04 PLU 2nd@ = 54 Starts “0001”. } Ends “the last record”. 6 : ~ : 6 a6 : ~ : 6 a 6 : ~: a 6s Start rec-# (Max. 4 digits) End rec-# (Max.
Character programming (P2) By character keyboard CE-7000 character keyboard RECEIPT FEED 1 SHIFT C JOURNAL FEED a B b CINS/ OVR 2 3 <— 7A —> C c D d E e F f G g H h I i J j K k L l P p Q q 8 7 8 9 M7 m N8 n O9 o 4 5 6 R4 r S5 s T6 t 2 3 9 0 0 00 • U1 u V2 v W3 w X0 x Y y Z z 5 1 4 DOUBLE SIZE 009 —> Á á 008 À à 007 Ä ä 006 1 C 8 7 8 9 4 5 6 ! 005 Q A #-2 2 3 0 B 9 #-1 0 00 • q 004 A 1 #-2 B #-1 TK-7000, TK-T500 character keyboard 2 3 JO
TK-7500/TK-6500 character keyboard 7 RECEIPT JOURNAL Û û FEED FEED 025 Î Á Í á Ó 008 À à Ò 007 Ä 006 ! q 004 A a Z z S w 6 1 e D d c r t 038 f G v g B b 088 097 087 096 « ¡ 7 067 & 8 u J 046 j K 055 n M , .
Character programming (P2) Entering characters By character code Chara Code Chara Code Chara Code Space 32 0 48 @ 64 P 80 ! 33 1 49 A 65 Q 81 " 34 2 50 B 66 R # 35 3 51 C 67 $ 36 4 52 D % 37 5 53 & 38 6 ' 39 ( Chara Code Chara Code Chara Code 96 p 112 Ç 128 a 97 q 113 ü 129 82 b 98 r 114 é 130 S 83 c 99 s 115 â 131 68 T 84 d 100 t 116 ä 132 E 69 U 85 e 101 u 117 à 133 54 F 70 V 86 f 102 v 118 å 134
Editing characters (only for CE-7000, TK-7000/7500, TK-T500) Correcting a character just entered OPERATION “L” “E” “N” “O” “N” yyy INS/ B OVR “M” DISPLAY (dot) 1 Enter LENON, instead of LEMON. LENON 1 Press left arrow key three times. LENON 1 Override mode LENON 1 Enter “M”. LEMON A A * A * A “*” means “OVR” mode. Correcting and adding a PLU descriptor already set OPERATION 15+ “S”, “o”,“d”, “a”, “ ” INS/ B OVR “L” 1 Enter “00”. 1 Enter PLU No. lemon 1 Enter “Soda” and “space”.
Character programming (P2) Issuing program reading report of program 2 mode Issuing procedure PGM TK-T500 CE-T300 6 2s 6 s P02......................... Mode switch GROSS NET CAID Report sample 0001-01 0002-01 0003-01 CE-7000, TK-7000/7500 TK-6000/6500 P02....................
Unit price/rate (Program 1) Date/time setting Date setting * PGM X 61s 6 : : : : : : 6 Mode switch Year Month or 6 C x Day Range: 1989 ~ 1999 89 ~ 99 = 1989 ~ 1999 00 ~ 88 = 2000 ~ 2088 * PGM Mode switch X 19 6 1s 6 : : : : : : 6 or 6 C 20 x Year Range: 1989 ~ 2088 Day You can use , or instead of these keys.
Unit price/rate programming (P1) Programming the 1st unit price and unit quantity (to PLU) To a new (not sequencial) PLU Different program to the next PLU Same program PGM 6 1s 6 PLU No.+ 6 : ~ : 6 a 6 s Mode switch (Rec No.
Rate program PGM 6 1s 6 : : : : ^ : : : : 6 E 6 s Integer (Max. 4-digits) Mode switch Example: $1.00 = ¥110.50 ¥100 = $0.9050 2 2 1^105 0^905 Decimal (Max. 4-digits) Preset rate , , , , PGM 6 1s 6 : : ^ : : 6 Appropriate key 6s Integer Decimal (Max. 2-digits) (Max.
Unit price/rate programming (P1) Issuing program reading report of program 1 mode Issuing procedure PGM 6 1s 6 s Mode switch Report sample CE-7000, TK-7000/7500 TK-6000/6500 P01.................... — Program read symbol CASH CHECK %- @100.00 — Transaction key unit price or rate @1.00 @1.00 10% DEPT01 0001-05 — Department descriptor/rec-#/file-# @1.00 — Unit quantity/unit price 0002-05 @2.00 1.2 DEPT02 1 TK-T500 CE-T300 P01......................... — Program read symbol CASH CHECK %- @100.
Program reading (Program 6) Issuing program reading report Issuing procedure Reading by file 6 6s 6 : : : s PGM Mode switch Reading code Reading by range 6 6s 6 : : : s 6 : ~ : a 6 : ~ : a Mode switch Report code Reading code File name Fix total Transaction key Subdepartment PLU Department Group Cashier/clerk Hourly sales Scanning PLU Table analysis Grand total General function Special character Report header Tax table Set menu table Batch X/Z Cashier detail link Hourly item (Item) Receipt message C
Program reading (P6) Report sample Fixed total TK-T500 CE-T300 CE-7000, TK-7000/7500 TK-6000/6500 P02......................... P02....................— Program 2 mode symbol GROSS NET CAID CATL GROSS NET CAID CATL 0001-01 0002-01 0003-01 0004-01 0001-01— Fix total descriptor/rec-#/file-# 0002-01 0003-01 0004-01 Transaction key Program 1 P01......................... P01....................— Program 1 mode symbol CHECK CASH %- CHECK CASH %- @10.00 @1.00 @2.20 10.24% @10.
Program 3 P03......................... P03.................... — Program 3 mode symbol SUBDEPT01 11-66 SUBDEPT02 11-66 SUBDEPT01 11-66 SUBDEPT02 11-66 0001-03 000000 0002-02 000000 0001-03 — Subdepartment descriptor/rec-#/file-# 000000 — Address code 11 program 0002-02 000000 PLU Program 1 P01......................... P01.................... — Program 1 mode symbol #000001 - #000010 PLU0001 0001-04 #000001 1.23 @10.00 PLU0002 0002-04 #000002 2.34 @30.
Program reading (P6) Department Program 1 P01......................... #0001 - #0010 DEPT01 1.23 DEPT02 2.34 0001-05 @10.00 0002-05 @30.00 P01.................... — Program 1 mode symbol — Department range #0001 - #0010 DEPT01 0001-05— Department descriptor/rec-#/file-# 1.23 @10.00— Unit quantity/unit price DEPT02 0002-05 2.34 @30.00 Program 2 P02......................... #0001 - #0010 DEPT01 DEPT02 DEPT03 0001-05 0002-05 0003-05 P02....................
Cashier/clerk Program 2 P02......................... P02.................... — Program 2 mode symbol #0001 - #0010 C01 C02 C03 0001-07 0002-07 0003-07 C01 C02 C03 — Clerk range #0001 - #0010 0001-07 — Clerk descriptor/rec-#/file-# 0002-07 0003-07 Program 3 P03......................... P03....................
Program reading (P6) Table analysis Program 2 P02......................... P02.................... — Program 2 mode symbol TBL01 TBL02 TBL03 TBL01 TBL02 TBL03 0001-18 0002-18 0003-18 0001-18— Table descriptor/rec-#/file-# 0002-18 0003-18 Program 3 P03......................... P03....................
Report header P02......................... P02.................... — Program 2 mode symbol FIX TRANS PLU FIX TRANS PLU 0001-24 0002-24 0003-24 0001-24 — Report header character/rec-#/file-# 0002-24 0003-24 Tax table P03......................... P03.................... — Program 3 mode symbol 0001-25 TX1 TX1 TX1 0001-25 TX1 TX1 TX1 12.3456% 0000 5003 — Rec-#/file-# 12.3456% — Tax table program data 0000 5003 P03......................... P03....................
Program reading (P6) Cashier detail link P03......................... P03.................... — Program 3 mode symbol 0001-30 GROSS 0002-30 NET 0001-30 GROSS 0002-30 NET 0001-01 0002-01 — Rec-#/file-# 0001-01 — Linked total descriptor/rec-#/file-# 0002-01 Hourly item (Item) P03......................... P03....................
Arrangement table P03......................... P03.................... — Program 3 mode symbol 0001-38 REG1 1 2 DEPT01 0001-38 REG1 1 2 DEPT01 000001 204-000 001-000 002-000 026-051 000001 — Rec-#/file-#/arrangement table -# 204-000 — Function descriptor/key-#/function-# 001-000 002-000 026-051 Character recall P02......................... P02....................
Program reading (P6) Program 3 P03......................... P03.................... — Program 3 mode symbol DISCOUNT01 @1.45 DISCOUNT02 DISCOUNT01 @1.45 DISCOUNT02 0001-51 000003 0002-51 0001-51 — Descriptor/rec-#/file-# 000003 — Discount amount/status 0002-51 PLU 2nd @ Program 1 P01......................... P01.................... — Program 1 mode symbol #000001 - #000010 PLU0001 0001-54 #000001 1.23 @10.00 PLU0002 0002-54 #000002 2.34 @30.00 — #000001 - #000010 PLU0001 0001-54 — #000001 — 1.
Order character P02......................... P02.................... — Program 2 mode symbol ORDER 01 KITCHEN BAR ORDER 01 KITCHEN BAR 0001-65 0002-65 0003-65 0001-65 — Descriptor/rec-#/file-# 0002-65 0003-65 Bottle link table P03......................... P03.................... — Program 3 mode symbol 0001-73 PLU0001 0002-73 0001-73 PLU0001 0002-73 0001-04 — Rec-#/file-# 0001-04 — Linked PLU descriptor/rec-#/file-# P03......................... P03....................
Program reading (P6) Program 3 P03......................... P03.................... — Program 3 mode symbol MC#01 MC#01 MC#02 0001-91 1001 0002-91 1002 MC#02 0001-91 — ID character/rec-#/file-# 1001 — Program 0002-91 1002 Printer connection table P03......................... P03.................... — Program 3 mode symbol 0001-93 0002-93 0003-93 0001-93 0002-93 0003-93 000000 100000 000000 000000 — Rec-#/file-#/program 100000 000000 AT command P02......................... P02.................
Miscellaneous message P02......................... P02.................... — Program 2 mode symbol GT TIME START DATE RAM GT TIME START DATE RAM 0001-78 0002-78 0003-78 0001-78 — Message/rec-#/file-# 0002-78 0003-78 P02......................... P02.................... — Program 2 mode symbol 0001-79 0001-79 0005-79 Direct Mainte Normal End 0006-79 0005-79 — Rec-#/file-# Direct Mainte Normal End — Message 0006-79 P02......................... P02....................
Program reading (P6) Registration guidance message P02......................... P02.................... — Program 2 mode symbol #0001 Not Found PLU Input Unit Price ,and Press DEPT key #0002 #0001 Not Found PLU Input Unit Price ,and Press DEPT key #0002 0001-81 0002-81 0003-81 0004-81 — Guidance No. (internal use) 0001-81 — Message/rec-#/file-# 0002-81 0003-81 0004-81 The messages in the same guidance No. are printed together on this report.
Auto-program & system utilities (Program 7) Auto-programming Using the auto-program function makes it possible to save and load the terminal program files. Methods available for saving the terminal program are as follows: 1) Saving another terminal connected through inline. 2) Saving onto a personal computer connected through online. 3) Saving onto a memory cassette. 4) Saving the internal flash memory.
Auto-programming/system utilities (P7) Command code list File No.
006 106 206 306 406 506 009 109 209 309 409 509 010 110 210 310 410 510 018 118 218 318 418 518 020 320 Check 015 056 060 Clerk 007 030 011 111 211 311 411 511 Command 900 Command 090/990 Command 092/992 Command 0xx/9xx Group (periodic total 1) (periodic total 2) (daily consolidation) (periodic 1 consolidation) (periodic 2 consolidation) Hourly sales (periodic total 1) (periodic total 2) (daily consolidation) (periodic 1 consolidation) (periodic 2 consolidation) Monthly sales (periodic total 1) (period
Auto-programming/system utilities (P7) File No.
Auto-programming operation To other terminal(s) through inline (Individual or all terminals) All terminal PGM 6 7s 6 50s 6 : : s 6 : : : a (Execution) Terminal ID No. Mode switch Command code 6 s (Cancellation) Note: Before executing this command, terminal connection table program is necessary. To other terminal(s) through inline (group terminals) All terminal PGM 6 7s 6 51s6 : : s6 : : : a (Execution) Mode switch Group No.
Auto-programming/system utilities (P7) From its internal flash memory 6 7s 6 21s 6 : : : a (Execution) PGM Command code Mode switch 6 s (Cancellation) From memory cassette 6 7s 6 20s 6 : : : a (Execution) PGM Command code Mode switch 6s (Cancellation) Other utilities Issuing system error log report 6 7s 6 1033s PGM Mode switch Report sample ---------(1033)--------GT TIME 003783 — START DATE 04-03-2000 — -----------------------— 01 0001 0001 — 000505 1058 0102 02 0000 0000 000000 0000 0000 03 0
Issuing memory cassette directory report 6 7s 6 1170s PGM Mode switch Issuing internal flash memory directory report 6 7s 6 1171s PGM Mode switch Report sample ---------(1170)--------- — PGM 1000.090 10,953 — FILE0001.090 1,024 — FILE0101.090 512 Title (print “1171,” if internal flash.) Auto-programming title/index capacity Auto-programming file name/file capacity Cf. FILEnnnn.
Auto-programming/system utilities (P7) Set the AT command to default value PGM 6 7s 6 2310s Mode switch Set the AT command to MODEM Before executing this command, you should connect a MODEM. 6 7s 6 4310s 6 a PGM (Execution) Mode switch 6s (Cancellation) Report sample ---------(2310)--------Modem set -----------------------AT&V ACTIVE PROFILE: — Modem response Normal End Set the graphic logo to the external printer Before executing this command, you should connect UP-350.
Manager operation This section describes modes and operations that are generally used by management only. Besides user programming procedure, it also describes how to perform clerk assignments for clerk interrupt function and set stock quantities. Manager control mode (X1 mode) • • • • • • Manager control consists of the six operations listed below. Access to these operations can be restricted by password that makes it impossible to perform operations unless the correct password is input.
Manager operation Stock quantity maintenance (PLU/flat PLU only) (for CE-7000, TK-7000/7500, TK-T500 only) You can make changes in actual stock quantities for PLU using the procedures described in this section. To add to the actual stock quantity of a PLU/flat PLU Procedure for PLU MGR To a new PLU To the next PLU Same value to the next PLU 6 2s 6 : ~ : + 6 : ~ : 6 a 6 s PLU No.
To input the new stock quantity of a PLU/flat PLU To a new PLU To the next PLU Same value to the next PLU Procedure for PLU MGR 6 8s 6 : ~ : + 6 : ~ : 6 a 6 s Adjusted value PLU No./random code Procedure for flat PLU To a new flat PLU Same value to the next PLU MGR FlatMENU 6 8s 6 B PLU 6 s SHIFT 6 : ~ : 6 B Adjusted value Clerk assignment Linking a clerk to a clerk interrupt buffer enables clerk interrupt while a transaction is in progress.
Manager operation Programming for the Euro This procedure is used for defining main/sub currency, currency exchange rate for the Euro, and drawer number for sub currency at the same time. Please follow the guidance receipts issued in each time during this procedure.
Type 3 procedure Result printing Guidance message Guidance message 6 : : : : : : 6 a 6 : 6a 66 : 6 a (Execution) Currency conversion rate Drawer No. Unit price conversion * This step is skipped, if the rate had been already set. 6 s (Cancellation) Abortion: s Type 4 procedure Guidance message 6 : : : : : : 6 a 66 Currency conversion rate * This step is skipped, if the rate had been already set.
Manager operation Programming for the Australian GST This procedure is used for defining • Tax symbol (*) is printed. • Taxable amount (receipt) is skipped. • “GST INCLUDED” is set to the TX1 descriptor. • “TAXABLE AMT” is set to the TA1 descriptor. • Total line is printed even in direct (cash) sales. • Australian rounding is set. • “$” is set to the monetary symbol. • Print “MOF message” on receipt. • Tax (10% tax rate, add-in tax, fraction rounding off) is set to the tax table 1.
Read/reset report issuance Preparation for issuing report Money declaration There are two ways to declare the money in drawer amount; money declaration in the REG1/REG2/RF mode or money declaration in the X1/Z1 mode. Both declarations release “money declaration compulsory.” Money declaration in the REG1/REG2/RF modes The register stores the declaration amount, declaration over and declaration short totalizers for each payment medium, and you can issue reports in the status of each totalizer.
Read/reset report Programmability • • • • • • • • • • • • Report issuance can be programmed with the following features: Suppress printing of zero total lines. Money declaration compulsory Report header message (report title) Print sales ratio Suppress printing of grand total Print two copies of the fixed total reset report. Print PLU number/random PLU codes on the PLU report and individual report. Clear (reset) actual stock quantity when the stock reset report programmed in a batch report is issued.
Clerk individual PLU individual by group Report code (Read: #=0 / Reset: # = 1) Consolidation file Daily Periodic 1 Periodic 2 Daily Periodic 1 Periodic 2 20017 2#117 2#217 20317 2#417 2#517 1020014 102#114 102#214 1020314 102#414 102#514 Clerk-No. Group-No. PLU individual by department PLU individual by subdepartment 2020014 3020014 202#114 302#114 202#214 302#214 2020314 3020314 202#414 302#414 202#514 302#514 Department-No. Subdept-No.
Read/reset report Report code Report name (Read: #=0 / Reset: # = 1) Target-No. PLU range by record number Consolidation file Daily Periodic 1 Periodic 2 Daily Periodic 1 Periodic 2 Start number 10014 1#114 1#214 10314 1#414 1#514 Start rec-No.
Batch report 6 :::: 6a X1/Z1 X2/Z2 D4 D3 D2 D1 Mode switch Report code Note: If you skip to enter the report code, the 1st batch X/Z is executed. :::: D4 D3 D2 D1 The value (record No.
Read/reset report Report sample TK-T500 CE-T300 CE-7000, TK-7000/7500 TK-6000/6500 Financial report X 03-04-2000(MON) 19:00 C01 MC#01 000001 — X1 mode symbol/date/time X 03-04-2000 19:00 C01 MC#01 000001 — Clerk descriptor/Mc-No./consecutive No. X X FLASH — Report header/title 0000071 — Report code FLASH 0000071 $13,575.07 -1.36 ⁄26.33 -1.73 DECLA 2734.973 $15,362.37 No 846 $13,601.80 $13,576.43 $13,575.07 -1.36 ⁄28.06 ⁄26.33 -1.73 $1.29 $4.63 -4.
Fixed total report Z FIX 19:10 012343 0001 0001011 — Mode symbol/date/time Z 03-04-2000 19:10 C01 MC#01 012343— Clerk descriptor/Mc-No./consecutive No. Z FIX $13,575.07 -1.36 ⁄26.33 -1.73 DECLA 2734.973 $15,362.37 NET No 846 $13,601.80 CAID $13,576.43 CATL $13,575.07 CA$1.36 CAID2 ⁄28.06 CATL2 ⁄26.33 CA$1.73 CR+ 2 $1.29 FSID $4.63 EBTTL -4.63 ----------------------------RF No 1 $10.25 CUST CT 123 AVRG $110.58 FEE $2.73 + $10.25 NB $102.54 C-1 $2.38 C-2 $57.46 CECA1 ¥12,793 CECK1 ¥1,000 CECK4 DM12.
Read/reset report Transaction key report Z 03-04-2000(MON) 19:15 C01 MC#01 000004 — Mode symbol/date/time Z 03-04-2000 19:15 C01 MC#01 000004 — Clerk descriptor/Mc-No./consecutive No. Z Z TRANS 0001 0001012 CASH No CH No CHKP CLK TRANS No No VOID No VLD RCT STORE RECALL No No No No 846 $13,601.80 12 $31.80 1 3 $12.34 4 $64.48 3 18 23 23 0001 — Report header/title/reset counter (Z only) 0001012 — Report code TRANS CASH CH CHKP CLK TRANS VOID VLD RCT STORE RECALL — No 846 $13,601.
PLU report All PLU/range/menu report Z 03-04-2000(MON) 19:25 C01 MC#01 000006 — Mode symbol/date/time Z 03-04-2000 19:25 C01 MC#01 000006 — Clerk descriptor/Mc-No./consecutive No. Z Z PLU 0001 0001014 0001 — Report header/title/reset counter (Z only) 0001014 — Report code PLU — PLU range (range report only) #000001 - #000500 #000001 - #000500 PLU0001 83.933 25.27% $1,373.39 OLD PRC $26.35 RED PRC $18.98 DISCOUNT $56.37 #000001 PLU0003 23 4.37% $63.44 DISCOUNT $0.
Read/reset report Best 50 report 1.......... PLU0001 83.933 25.27% $1,373.39 OLD PRC $26.35 RED PRC $18.98 DISCOUNT $56.37 #000001 2.......... PLU0050 67 21.19% $1,152.06 OLD PRC $66.75 RED PRC $38.96 DISCOUNT $43.37 #000045 50......... PLU0038 3 6.87% $373.39 OLD PRC $2.57 RED PRC $7.64 DISCOUNT $8.37 #000038 ----------------------------TL 207.933 $2,871.63 RED PRC $44.31 DISCOUNT $86.53 — 1.......... PLU0001 83.933 — 25.27% $1,373.39 — OLD PRC $26.35 — RED PRC $18.98 — DISCOUNT $56.37 — — #000001 2......
By group/department/subdepartment report GROUP01 PLU0001 #000001 PLU0002 ..........01 15 73 * 15 3 #000010 PLU0011 #000001 PLU0002 ..........01— Classification title (by group/dept./subdept) — PLU character/optimum stock quantity 15 — Current stock quantity 73 * 15 3 — PLU code (4-digit) or Random code (6-digit) — * means out of optimum stock quantity #000002 #000002 GROUP02 PLU0010 GROUP01 PLU0001 ..........02 30 73 20 23 GROUP02 PLU0010 #000010 PLU0011 ..........
Read/reset report Best 50 report 1.......... DEPT01 83.933 25.27% $1,373.39 OLD PRC $26.35 RED PRC $18.98 DISCOUNT $56.37 2.......... DEPT50 67 21.19% $1,152.06 OLD PRC $66.75 RED PRC $38.96 DISCOUNT $43.37 50......... DEPT38 3 6.87% $373.39 OLD PRC $2.57 RED PRC $7.64 DISCOUNT $8.37 ----------------------------TL 207.933 $2,871.63 RED PRC $44.31 DISCOUNT $86.53 — 1.......... DEPT01 83.933 — 25.27% $1,373.39 — OLD PRC $26.35 — RED PRC $18.98 — DISCOUNT $56.37 — 2.......... DEPT50 67 21.19% $1,152.
Clerk report Z 03-04-2000(MON) 19:10 C01 MC#01 000008 — Mode symbol/date/time Z 03-04-2000 19:10 C01 MC#01 000008 — Clerk descriptor/Mc-No./consecutive No. Z Z DECLA EURO MONEY C01 GROSS NET CAID CHID CKID CRID RF C-1 C-2 CLEAR 0001 0001017 CASHIER $13,575.07 -1.36 ⁄26.33 -1.73 DECLA ................1 2734.973 $15,362.37 No 846 $13,601.80 $13,576.43 $4.87 $273.97 $28.06 No 1 $10.00 $3.09 $8.
Read/reset report Hourly sales report Z 03-04-2000(MON) 19:45 C01 MC#01 000010 — Mode symbol/date/time Z 03-04-2000 19:45 C01 MC#01 000010 — Clerk descriptor/Mc-No./consecutive No. Z Z HOURLY 0001 0001019 00:00->01:00 CT GROSS NET 10.67% No 12 $1,373.39 12 $1,373.39 01:00->02:00 CT 26 GROSS $4,253.64 NET No 12 2.67% $343.55 ----------------------------TL CT 4357 GROSS $12,871.63 NET No 3674 $12,881.
Table analysis report Z 03-04-2000(MON) 19:55 C01 MC#01 000012 — Mode symbol/date/time Z 03-04-2000 19:55 C01 MC#01 000012 — Clerk descriptor/Mc-No./consecutive No. Z Z ANALYSIS 0001 0001028 TBL01 CT 34 10.66% $1,373.39 TBL02 CT 27 29.24% $3,767.65 TBL20 CT 23 2.67% $344.84 ----------------------------TL CT 162 $12,881.00 ANALYSIS 0001 — Report header/title/reset counter (Z only) 0001028 — Report code — TBL01 CT 34 10.66% $1,373.39 — TBL02 CT 27 29.24% $3,767.65 TBL20 CT 23 2.67% $344.
Read/reset report Open check report Z 03-04-2000(MON) 20:05 C01 MC#01 000014 — Mode symbol/date/time Z 03-04-2000 20:05 C01 MC#01 000014 — Clerk descriptor/Mc-No./consecutive No. Z Z OPEN CHECK 0001 0001025 OPEN CHECK 0001 — Report header/title/reset counter (Z only) 0001025 — Report code C03 MC#01 000003 REG 03-04-2000(MON) 09:02 TABLE No.123456 CT 12 CHECK No.123 $250.00 C03 MC#01 000003 — — REG 03-04-2000 09:02 TABLE No.123456 CT 12 — — CHECK No.123 $250.
Best 50 report DEPT01 ......01 1...... SCAN_PLU002 382 38.01% $3,526.46 #4934567890124 2...... SCAN_PLU001 285 #4912345678904 50..... SCAN_PLU003 72 10.49% $973.45 #4956789012344 ----------------------------1253 $9,275.83 DEPT01 ......01 — — 1...... — SCAN_PLU002 382 38.01% $3,526.46 — — #4934567890124 2...... SCAN_PLU001 285 #4912345678904 50..... SCAN_PLU003 72 10.49% $973.45 #4956789012344 -----------------------1253 — $9,275.
Read/reset report Not found PLU report Z 03-04-2000(MON) 20:20 C01 MC#01 000018 — Mode symbol/date/time Z 03-04-2000 20:20 C01 MC#01 000018 — Clerk descriptor/Mc-No./consecutive No. Z Z NFP 0001 0001027 #4901234567894 382 17.07% $1,583.47 #4989012345674 35 38.01% $3,526.46 #4967890123454 12 10.49% $973.45 ----------------------------TL 1265 $5,375.93 NFP 0001 — Report header/title/reset counter (Z only) 0001027 — Report code — #4901234567894 382 17.07% $1,583.47 — #4989012345674 35 38.01% $3,526.
File reset PLU reset Z 03-04-2000(M0N) 22:25 C01 MC#01 000050 — Mode symbol/date/time Z 03-04-2000 22:25 C01 MC#01 000050 — Clerk descriptor/Mc-No./consecutive No. Z Z PLU PLU Z clear 0001 0051014 Normal End PLU PLU Z clear 0001 — Report header/title/reset counter 0051014 — Report code Normal End — Action/result Scanning PLU reset Z 03-04-2000((MON) 22:30 C01 MC#01 000051 — Mode symbol/date/time Z 03-04-2000 22:30 C01 MC#01 000051 — Clerk descriptor/Mc-No./consecutive No.
Read/reset report 174
Consolidation X/Z consolidation This is used when it is desirable to obtain the counters and totals of all terminals in the store. After consolidating data from all specified terminals, the master prints the details on the receipt/journal printer. First of all, allocate the appropriate consolidation files and program the terminal connection table. During the X consolidation, the satellite terminals send data and do not print out the reports.
Consolidation Z consolidation processing (except for scanning PLU) Z consolidation processing is performed as the figure shown below. 1, 6 Satellite Master Terminal files Terminal files 5 2 Consolidation files 3 1 A Z consolidation command is started up from the master terminal. The master first locks objected terminals. 2 Data of the master's terminal files are copied to the consolidation file.
Scanning PLU maintenance by consolidating the not found PLU file During registrations, the item that has not existed in the PLU or not found PLU file is stored in the not found PLU file when the item is registered. So, after business hours, you should merge the items in the not found PLU file to the PLU (main) file. To merge the contents of the not found PLU file to the main file, consolidation of the not found PLU is necessary, even if you have only one scanning terminal.
Consolidation X/Z consolidation execution Consolidate terminal by terminal X1/Z1 X2/Z2 6 2222s 6 : : s 6 : ~ : 6 a Terminal ID No. Report code *1 Mode switch *1 If you skip to enter the report code, the 1st batch X/Z is executed. Consolidate by group No./all terminal X1/Z1 X2/Z2 61111s 6 : : : s 6 : ~ : 6 a Group No. *1 Report code *2 Mode switch *1 *2 All terminals are selected, if you skip to enter the group No. If you skip to enter the report code, the 1st batch X/Z is executed.
Consolidate individual clerk report by group No./all terminal X1/Z1 X2/Z2 6 1111s 6 : : : s6 : ~ : a6 : : a Group No. *1 Report code Clerk No. Mode switch *1 All terminals are selected, if you skip to enter the group No. Execute file reset command to all terminal X1/Z1 X2/Z2 6 1111s 6 : ~ : a6 Report code { a (Execution) s (Cancellation) Mode switch Scanning PLU reset (no report) Not found PLU file reset (incl.
Consolidation X/Z consolidation report sample Z consolidation Master terminal Z 03-04-2000 19:00 C01 MC#01 000001 INLINE 2222 00011 — INLINE/command No.
Application systems Scanning PLU (CE-7000, TK-7000/7500, TK-T500 only) You can register items by scanning. System configuration of the scanning PLU system • Maximum 4 terminals • Each terminal has its own scanning PLU files. • Scanning PLU files (such as scanning PLU file, batch maintenance PLU file, not found PLU file, not found PLU maintenance file and PLU direct maintenance file) are necessary to all terminals connected in the same inline (cluster). Setup Application systems 1.
Application systems PLU maintenance There are three ways to maintain scanning PLU, i.e. not found PLU maintenance, batch PLU maintenance and direct PLU maintenance. Not found PLU maintenance When an item which code is not existed in the scanning PLU file is registered, the “Not found” error occurs. You can register this item by not found PLU maintenance procedure. After this maintenance, this item is registered without the “Not found” error.
Direct maintenance Direct maintenance is used for adding items to the scanning PLU file, or changing the scanning PLU item programming data. 1 Program the direct maintenance PLU file. Note: After direct maintenance, broadcast the scanning PLU file to all terminals of the cluster. 1 Satellite Master Scanning PLU file Scanning PLU file Direct maintenance PLU file Scanning PLU registration By scanner/code input/one touch NLU key OPERATION Scan-PLU ($2.
Application systems Price change operation When a scanning PLU item is programmed to enable to change price, you can change the unit price temporarily. The preset price in the scanning PLU file is not changed by this operation. You can restrict the temporary price is less/greater than the programmed unit price by the general function program. OPERATION PRC ($1.20) 100B CHG Scan-PLU ↓ Temporary unit price $1.00 Item ————————— PLU code 49012361 “Scanning” ————————— This item should be programmed as Dept.
Mix & match discount There are three types of mix & match processing: • Discount 1 (discount every required quantity) • Discount 2 (discount one time per one transaction) • Discount 3 (discount continuously) Mix & match discount affects to the item totalizer, link dept/subdept totalizer and link dept/subdept discount totalizer, when the “Net totaling” option is selected.
Application systems Discount type 3: In this type of processing, a discount is made when the quantity of a particular scanning PLU reaches a certain number during registration. And this discount is made after this item registration. OPERATION Scan-PLU ($0.34) “Scanning” ————————— Item PLU code 49012361 “Scanning” ————————— Quantity 4 “Scanning” ————————————— Mix & match discount is made. Discount type 3: 3/ $0.02 ————————————— Payment Cash $1.32 “Scanning” Mix & match discount is made.
Printing on the external printers You can print receipts/reports/orders on external printer(s). Maximum 2 external printers can be connected to one terminal, so it is possible to print out to another printer (i.e. another external or internal R/J) for backup. Note: The printouts from other terminal which is connected in the same inline cannot be printed on the external printer of that terminal. The printouts from R/J printer and external printer can be divided into 3 types; 1. Receipt type, 2.
Application systems Printing control options for order Below shows the summary of the programmable options for order printing. Programmable oprion Number of feed lines before order printing (1 ~ 9) Number of feed lines after order printing (1 ~ 9) Cut order Show guidance for backup print of order. Alert when the external printer goes down. Baud rate Backup destination Merge the same item registration on order receipt. (Item consolidation) Breakdown set menu printing on order. Print order with amount.
Tips Future order This is an enhancement of the training function. By using the original training specification, the training clerk cannot accept any customer. Because no journal printing and no memory affection of this function is made. By using “Future order”, you can get this sales data and journal printing even if the transaction is registered by the training clerk. Usage Receipt issuance: OFF 1. Start training. (Sign on a training clerk.) During training 2.
Tips Automatic execution of Euro switchover by arrangement and scheduler The following sample shows an automatic execution program of arrangement and scheduler. Sample program Execution date/time: Currency definition type: Currency conversion rate: Drawer of sub currency: Unit price conversion: 31. December 2001 23:59 3 (Main currency = Euro, Sub currency = Local, Change = Euro) 1 Euro = 6.55957 F Franc Main Yes • Arrangement *2 PGM *1 6 3s 6 : ~ : 38s 6 A 6 : ~ : a 6 Arrangement table No.
Appendix: Calculation method The following calculation methods of totalizer memories are explained in this chapter. • All formulas in these explanations are calculated in the registration mode. • In the RF mode, the values in totalizers are calculated using the opposite sign. • In the REG– mode, the value in totalizers and counters are calculated using the opposite sign.
Appendix (Calculation method) Total or Counter Medium in drawer (Cash, charge, check, credit, Food stamp, EBT) Declared short medium amount (except Food stamp, EBT) Declared over medium amount (except Food stamp, EBT) Number of RF mode items RF mode amount Customer count Average sales per customer Check cashing service fee New balance fee Clerk commission total Foreign currency in cash drawer Foreign currency in check drawer Discount Amount Item return amount Clear count Rounding Taxable amount Increment
Appendix: Font code tables These models have the capability to print/display in Slavic, Greek, Cyrillic, Baltic, Arabic fonts. If you want to use these special font set, initialize the machine and enter the special initialization code (D14 ~ D12) before the original code 1 (D11 ~ D1). (Refer to the initialization chapter.
Appendix (Font table) Special font set Slavic (Windows code page 852) Special initialization code D14 D13 D12 = 010 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Ç 128 ü 129 É 144 á 160 176 192 208 145 í 161 177 193 209 162 178 163 179 180 181 Chara Code Chara Code Ó 240 225 241 é 130 146 ó â 131 ô 147 ú ä 132 ö 148 164 u 133 149 165 c 134 150 166 182 198 Í 214 230 246 ç 135 151 167 183 199 Î 215 231 247 136 Á 194 Ë 210
Cyrillic (Windows code page 866) Special initialization code D14 D13 D12 = 030 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code 160 176 192 208 p 224 145 161 177 193 209 c 225 130 146 162 178 194 210 226 131 147 163 179 195 211 227 128 144 129 a 240 ë 241 242 243 164 180 196 212 228 Ï 165 181 197 213 229 ï 150 166 182 198 214 230 246 151 167 183 199 215 231 247 136 152 168 184 200 216 232 248 137 153
Appendix (Font table) Arabic Special initialization code D14 D13 D12 = 050 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code 128 ß 129 • 130 Ø 144 160 176 192 208 224 240 145 161 177 193 209 225 241 162 178 194 210 226 242 147 £ 163 179 195 211 227 243 132 148 ¤ 164 180 196 212 228 244 133 149 165 181 197 213 229 245 131 134 146 150 166 182 198 214 230 246 135 « 151 167 183 199 215 231 247 136 » 152 168 184 200 216
Appendix: Peripheral device configuration UP-350 1 SW No.
Appendix (Peripheral configuration) SP-1300 DIP switch under the document table SW No.
Appendix: File record format Fixed total file Fixed total (daily) File name: Fixed total (daily) 0 12 Character File No.: 001 Max. allocatable records: 97(fixed) 17 Counter 22 Totalizer Fixed total (periodic/consolidation) File name: File name: File name: File name: File name: 5 Counter Rec No. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 File No.: File No.: File No.: File No.: File No.
Appendix (File record format) Transaction key file Transaction key (daily) File name: Transaction key (daily) 2 File No.: 002 14 Function code 0 Character 21 Program 25 30 Max.
PLU file PLU (daily) Old Red amount amount totalizer totalizer Program 0 16 Character 23 Program 44 45 48 HALO Order 41 Minimum stock Bottle/setmenu link Unit quantity Max.
Appendix (File record format) Department file Department (daily) File name: Department (daily) 0 16 Character 23 Program 0 16 Character Program 26 Link 23 29 26 Link HALO 32 @ 29 HALO 32 @ 35 36 39 Order @ 3536 Double Bon Link 32 44 35 44 Counter Max. allocatable records: 99 49 54 Old Totalizer Discount amount totalizer totalizer Counter 39 Order Program 29 Double Bon Character 26 Unit quantity 23 Unit quantity 16 Unit quantity 0 File No.
Group file Group (daily) File name: Group (daily) 0 12 Character 17 Counter File No.: 006 Max. allocatable records: 99 File No.: File No.: File No.: File No.: File No.: Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max.
Appendix (File record format) Clerk file Clerk (programming) File name: Clerk (programming) 15 16 18 Character Drawer # Check # 12 Clerk initioal check # 0 23 Program 23 Program 27 Commission rate Character File No.: 007 15 16 18 27 Commission rate 12 Clerk initioal check # Drawer # Check # 0 33 Check # range Max.
Hourly sales file Hourly sales (daily) File name: Hourly sales (daily) 4 End time 2 Start time 0 9 14 No. of customer Gross total 19 No. of transaction File No.: 009 Max. allocatable records: 99 File No.: File No.: File No.: File No.: File No.: Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max.
Appendix (File record format) Scanning PLU files (only for CE-7000, TK-7000/7500, TK-T500) Scanning PLU file (daily) Character 31 33 Link 36 38 4041 @ Last update date Mix & match link 27 Bottle link PLU code 24 Program 7 8 Multi price flag 0 File No.:016 Max. allocatable records: 20000 Unit quantity File name: Scanning PLU 46 Counter 51 Totalizer Not found PLU file (daily) File name: Not found PLU PLU code 11 Link File No.:017 Max.
(only for CE-7000, TK-7000/7500, TK-T500) One touch NLU table file File name: One touch NLU table 0 File No.:077 Max. allocatable records: 999 7 Scanning PLU code Mix & match file (only for CE-7000, TK-7000/7500, TK-T500) Mix & match file (daily) File name: Hourly sales (daily) Character 15 @ 18 23 Max. allocatable records: 99 28 30 Counter Totalizer Work 12 Program 0 File No.
Appendix (File record format) Table analysis file (except for CE-6000/6100, CE-T300) Table analysis (daily) File name: Table analysis (daily) 15 Character 18 Maximum check No. 12 Minimum check No. 0 23 File No.: 018 Max. allocatable records: 99 File No.: File No.: File No.: File No.: File No.: Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max. allocatable records: 99 Max.
Hourly item file (only for CE-7000, TK-7000/7500, TK-T500) Hourly item sales file File name: File name: File name: File name: File name: File name: 0 Hourly item sales (daily) Hourly item sales (periodic 1) Hourly item sales (periodic 2) Hourly item sales (daily consolidation) Hourly item sales (periodic 1 consolidation) Hourly item sales (periodic 2 consolidation) 5 Counter File No.: File No.: File No.: File No.: File No.: File No.: 021 121 221 321 421 521 Max. allocatable records: 99 × 99 Max.
Appendix (File record format) General control file General control File name: General control 0 File No.: 022 Max. allocatable records: 37 (fixed) 5 Program Rec No. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 210 Contents Date order, Monetary mode Password, Machine ID., Machine No.
Special character file Special character File name: Special character 0 File No.: 023 Max. allocatable records: 42 (fixed) 16 Character Contents 01 main currency symbol (2), @ (2), No. (2), split pricing (2), not used (1) training filler (1), training symbol (1), not used (1), sub currency symbol (2) 02 No. of item sold (2), No.
Appendix (File record format) Report header file Report header File name: Report header 0 File No.: 024 Record No. 12 Max.
Batch X/Z file Batch X/Z File name: Batch X/Z File No.: 029 Max. allocatable records: 10 File No.: 032 Max. allocatable records: 39 12 13 14 15 1617 18 19 20 21 22 23 Character Mode X/Z code (1) X/Z code (2) X/Z code (3) X/Z code (4) X/Z code (5) X/Z code (6) X/Z code (7) X/Z code (8) X/Z code (9) X/Z code (10) 0 Receipt message file Receipt message File name: Receipt message 0 24 Rec No.
Appendix (File record format) Arrangement file Arrangement file File name: Arrangement File No.: 038 Max. allocatable records: 9999 File No.: 039 Max.
System files Character key table file File name: Character key table File No.: 046 Max. allocatable records: 73 (CE-series), 108 (TK-series) 2 4 6 1st character code 2nd character code 3rd character code 0 Key/character key table record No.
Appendix (File record format) Key table file File name: Key table File No. 3 4 Record No./random PLU code 0 File No.: 074 Max. allocatable records: 87 (CE-6000/6100, CE-7000, CE-T300), 150 (TK-6000/7000, TK-T500), 148 (TK-6500/7500) Key/key table record No.
Terminal connection table file (except for CE-6000/6100, CE-T300) File name: Terminal connection table Max. allocatable records: 32 8 10 Program 0 File No.: 091 Machine ID. character Printer connection table (except for CE-6000/6100 CE-T300) File name: Printer definition table File No.: 093 Max. allocatable records: 7 File No.: 094 Max. allocatable records: 1 (fixed) File No.: 095 Max. allocatable records: 1 (fixed) File No.: 096 Max.
Appendix (File record format) Online password file File name: Online password 0 File No.: 097 Max. allocatable records: 1 8 Character I/O parameter table file File name: I/O parameter table File name: I/O parameter table 0 File No.: 098 Max. allocatable records: 1 (fixed) (for CE-6000/6100, CE-T300) File No.: 098 Max. allocatable records: 4 (fixed) (for other models) 8 Program System error log file File name: System error log File No.: 099 Max.
Guidance message files Error message file (only for CE-7000, TK-7000/7500, TK-T500) File name: Error message 0 File No.: 080 Max. allocatable records: 191(fixed) 16 Character Meaning 001 002 003 004 Error code (do NOT change) Mode switch position changed before finalization. Error code (do NOT change) Clerk button pressed before finalization of a registration being performed under another clerk button. The signed on clerk differs from the clerk performed the tracking check registration.
Appendix (File record format) Rec-No. 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101~103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 Meaning Error code (do NOT change) Finalization of a transaction attempted without confirming the subtotal.
182 Meaning Error code (do NOT change) External printer offline Error code (do NOT change) External printer went down. Error code (do NOT change) External printer paper end (1/2) External printer paper end (2/2) Error code (do NOT change) External printer is now printing. Error code (do NOT change) Printing buffer full (1/2) Printing buffer full (2/2) Error code (do NOT change) Attempt to finalize a transaction when balance is less than or equal to zero.
Appendix (File record format) Rec-No. 183 184 185 186 187 188 189 190 191 192 193 Meaning Error code (do NOT change) Attempt to print the last separated transaction on slip. (1/3) Attempt to print the last separated transaction on slip. (2/3) Attempt to print the last separated transaction on slip. (3/3) Error code (do NOT change) Printer error: Paper jam, Printer head is released. (for CE-T300, TK-T500) (1/2) Printer error: Paper jam, Printer head is released.
Guidance message file Miscellaneous message file File name: Miscellaneous message 0 File No.: 078 Max.
Appendix (File record format) Printing guidance message file File name: Printing guidance message 0 File No.: 079 Max. allocatable records: 78(fixed) 24 Character Rec-No.
(only for CE-7000, TK-7000/7500, TK-T500) X/Z guidance message file File name: X/Z guidance message File No.: 082 Max. allocatable records: 38(fixed) 0 16 Character Meaning PLU range report message 1st line Input start No. message 1st line Input start No. message 2nd line PLU range report message 1st line (quote from rec-001) Input end No. message 1st line Input end No. message 2nd line PLU stock range report message 1st line Input start No. message 1st line (quote from rec-002) Input start No.
Appendix (File record format) Rec-No. 019 ----------020 ----------021 022 023 024 025 ----026 ----027 ----028 029 030 031 032 033 034 --035 036 037 ----038 ----- Meaning PLU best report message 1st line Input start No. message 1st line (quote from rec-002) Input start No. message 2nd line (quote from rec-003) PLU best report message 1st line (quote from rec-016) Input end No. message 1st line (quote from rec-004) Input end No.
Program guidance message file (only for CE-7000, TK-7000/7500, TK-T500) File name: Program guidance message File No.: 083 Max. allocatable records: 92(fixed) 0 16 Character Meaning Range program message 1st line Input start No. message 1st line Input start No. message 2nd lilne Range program message 1st line (quote from rec-001) Input end No. message 1st line Input end No.
Appendix (File record format) Rec-No. 028 029 --030 031 ----------------------------032 033 034 --035 036 037 --038 039 040 --041 042 043 --044 045 046 --047 048 049 --050 051 052 053 054 055 056 --057 058 059 060 061 062 063 ----------- Meaning Batcht maintenance programming message 1st line Input batch maintenance record No.
Meaning Please wait message Default (English) message Please wait Auto-program (register to register) message Input target machine No. message 1st line Input target machine No.
Appendix (File record format) (only for CE-7000, TK-7000/7500, TK-T500) Registration guidance message file File name: Registration guidance message File No.: 081 Max. allocatable records: 11(fixed) 0 16 Character Rec-No.
Appendix: Compulsory This section explains the priority compulsions and the methods to solve them. Compulsions at the first item registration Priority Error code Meaning 1 E017 Force to enter check number. 2 3 E018 E019 Force to enter table number. Force to enter the number of customer. Released by ✔ ✔ ✔ Action Register check number by , , . Register table number. Register the number of customer.
Appendix (Compulsory) 220
Appendix: Error code Message Meaning E001 Wrong mode Mode switch position changed before finalization. E003 Wrong operator E004 E005 Error INIT/FC Insufficient memory Please sign on Enter password Close the drawer Clerk button pressed before finalization of a registration being performed under another clerk button. The signed on clerk differs from the clerk performed the tracking check registration. Initialization or unit lock clear operation in progress.
Appendix (Error code) Error code (…continued) Error code Message E049 CHECK memory full E050 DETAIL memory full E051 CHK/TBL No. is occupied E053 CHK/TBL No. is not opened E054 Out of CHK/TBL No.
System error code Meaning File I/O errors 750 File cannot be created. 751 No designated drive 752 FCB area shortage of flash memory 753 No appropriate record number is designated. 754 No partation exists. 755 No vacant record is remained. 756 Changing is not permitted. 757 The designate file cannot be found. 758 The same file has already existed. 759 The same page has already existed. 760 No vacant record is remained. 762 The contents of internal memory and memory cassette are different.
Appendix (Error code) 224
Index A action code 107 activation of batch maintenance 105 activation of Not found PLU maintenance 106 add check 85 add-in rate tax 94 add-on rate tax 91 Arabic font 196 arrangement 75, 97 arrangement file 214 arrangement table 137 AT command 116, 140 AT command file 217 Australian GST 154 auto-program 141, 145 B backup system for external printer 187 Baltic font 195 barcode system 181, 188 batch feature programming 57 batch maintenance 105, 182 batch maintenance PLU file 206 batch X/Z 135 batch X/Z file
Index financial report 160 fixed total 111, 130, 191, 199 flag clear 25 flat-PLU 57, 59, 119 font code 193 food stamp shift 85 food stamp subtotal 85 food stamp tender 64 formatting of internal flash memory 147 formatting of memory cassette 147 future order 189 IPL via inline 20 IPL via memory cassette 21 issuing program reading report 129 item/clerk descriptors by range 119 J job command table 100 K Ketten Bon 82 key allocation 35 key function/machine feature 39 key table file 216 G general control fil
Index print control for guest receipt and slip 52 print control for receipt 41 print control for report 49 print control for taxable amount 46 printer connection table 140, 187, 217 printing guidance message 116-1, 140-1 printing guidance message file 218-6 printing history 2 program 1 programming in X1 mode 149, 154 program guidance message 116-2, 140-2 Program guidance message file 218-9 program reading report of program 1 128 program reading report of program 3 110 program reading report of program 5 33
Index scanning PLU direct maintenance 107, 127 scanning PLU file 206 scanning PLU maintenance 105, 177 scanning PLU report 170 scanning PLU reset 173 scanning system 16 scanning system setup 181 scheduler 99, 138 scheduler file 214 secret number 86 separate check 85 set menu 60 set menu table 135 set menu table file 212 set the AT command to default value 148 set the AT command to MODEM 148 Singapore tax 94 Slavic font 194 slip 77 slip backfeed/release 85 slip feed/release 85 slip print 189 slip printer 14
Index Index CE-7000/TK-7000/TK-7500/TK-T500/TK-6000/TK-6500 Dealer's Manual 229
CASIO COMPUTER CO., LTD.