User's Guide

E-42
IT-2060IOE Optional Optical Communication Unit
Daisy Chaining Optical Communication Units
An optional DT-888RSC 6-6 Pin Modular Cable can be used to daisy chain up to seven
Optical Communication Units. In this configuration, a personal computer can exchange data
with multiple Data Collectors simultaneously.
Daisy Chain Configuration
Connect the C-OUT terminal of the Optical Communication Unit that is closer to the host
computer to the C-IN terminal of the next Optical Communication Unit.
The following are the required DIP switch settings for Optical Communication Units in a
daisy chain configuration. See page E-43 for details on actually making DIP switch settings.
The Optical Communication Unit furthest from the computer must be defined as the
Terminator Unit in Linked Chain.
The Optical Communication Unit connected to the computer must be defined as the Host
Computer Connection.
All other Optical Communication Units must be defined as Intermediate Unite in Linked
Chain.