Operation Manual

46
ATS0=
n
[&F] [&W]
Specifies how many times
the FOMA terminal rings
before it automatically
receives a call.
n
= 0 : No automatic answer (initial value).
n
= 1- 255: A call is automatically answered
after the specified number of
rings.
ATS0?: Displays the current setting.
ATS0=0
OK
ATS0?
000
OK
ATS2=
n
[&F]
Sets an escape character.
n
= 43 : Initial value.
n
= 127 : Escapes processing is invalid.
ATS2? : Displays the current setting.
ATS2=43
OK
ATS2?
043
OK
ATS3=
n
[&F]
Sets a carriage return (CR)
character.
n
= 13 : Initial value (Only
n
= 13 can be
specified).
ATS3? : Displays the current setting.
ATS3=13
OK
ATS3?
013
OK
ATS4=
n
[&F]
Sets a line feed (LF)
character.
n
= 10 : Initial value (Only
n
= 10 can be
specified).
ATS4? : Displays the current setting.
ATS4=10
OK
ATS4?
010
OK
ATS5=
n
[&F]
Sets a backspace (BS)
character.
n
= 8 : Initial value (Only
n
= 8 can be
specified).
ATS5? : Displays the current setting.
ATS5=8
OK
ATS5?
008
OK
ATS6=
n
[&F]
Sets the pause time
(second) until a dial starting.
This command can be set but cannot be
operated.
ATS6=5
OK
ATS6?
005
OK
ATS6=?
ERROR
ATS8=
n
[&F]
Sets the pause time
(second) by using the
comma dial.
This command can be set but cannot be
operated.
ATS8=3
OK
ATS8?
003
OK
ATS8=?
ERROR
ATS10=
n
[&F][&W]
Automatic disconnection
delay time setting.
(1/10 second)
This command can be set but cannot be
operated.
ATS10=1
OK
ATS10?
001
OK
ATS10=?
ERROR
ATS30=
n
[&F]
Disconnects the line when
there is no user data
exchange for the time set in
this command.
n
= 0 : Inactive timer off (initial value)
n
=0 - 255
Where n is the number of minutes.
ATS30=0
OK
ATS30?
000
OK
ATS30=?
ERROR
ATS103=
n
[&F]
Sets the called sub address
character.
n
=0 :
n
=1 / (initial value)
n
=2 ¥ (¥ mark or back slash)
ATS103=0
OK
ATS103?
000
OK
ATS103=?
ERROR
AT command Outline Parameter/description
Command execution example
CA-01C_E_Manual_02.fm 46 ページ 2011年5月3日 火曜日 午後12時30分