Specifications
— 56 —
3. Pressing OK button, the following display will appear.
The contrast value is
written'
4. Tapping Yes, this adjustment is completed.
5. If you adjust the contrast to EvolVal = 5, EvolValue = 5(c4h) display will appear in Main Menu.
8-3-10. To abort or complete this Operation Check
1. Tap 13 Exit in Main Menu.
2. Never press Power button after tapping 13 Exit.
Otherwise, any malfunction will occur.
3. Be sure to perform the initialization immediately without turning off the checking unit after tapping 13
Exit.
To initialize the checking unit, press RESET button while holding down Power button.
Be sure to perform the calibration after that.
4. Restore factory defaults.
5. Restore the user's data and settings.
8-3-11 . The other information
1. The communication checks are not needed because the checking unit is connected to PC and CF card
before the operation check.
2. Never try to perform 10 UUID_Code Write in Main Menu.
This setting can be performed only in the factory.
UUID Code is the individual identified code for the each unit.
UUID Code is a sort of the licensed key to download the copyright files.
Therefore, never try to change UUID Code.
3. Performing 12 PCB Check in Main Menu, This PCB is Old or This PCB is New display may appear.
Both PC Board Assemblies may be interchangeable.
Using this check, the interchangeability of PC Board Assembly can not be judged.
Refer to 7-3. Back Up and Restore in this manual concerning the interchangeability of PC Board
Assembly.