Specifications

— 45 —
8. DIAGNOSTIC PROGRAM AND OPERATION CHECK
To abort the operation check, you must tap 13 Exit In Main Menu for the peration check. Tapping 13
Exit, user's data will be deleted, but use's settings may remain. Turning off the unit after tapping 13
Exit, the checking unit will occur malfunction when turning on the unit. After tapping 13 Exit, be sure
to perform the initialization pressing RESET button while holding down Power button. After that, be
sure to perform the calibration. The complete initialization can not be performed without this
calibration.
If this complete Initialization is not performed, try again tapping 13 Exit after entering into the operation
check mode again.
If you don't want to delete user's data, you should save user's data in CF Card or PC pertorming
Back up operation before starting the operation check. If any password is registered and password
entry request display appears after turning on the unit, the operation check can not be started. If this
display appears, start the operation check after entering the password. Even if any password is
registered, you can perform Back up operation after entering into SAFE Mode described in the prior
pages (7-3. Back Up and Restore). If any malfunction is found out with the operation check, it is
recommended to pertorm the operation check again after restoring factory defaults. It is recommended
to perform the following procedure on the safety side.
1. Save the user's data and settings performing Back up operation.
2. Perform the operation check.
3. Complete the operation check tapping 13 Exit.
4. Perform the complete initialization.
5. Restore factory defaults.
6. Restore the user's data and settings.
Anyway, be sure to save user's data at first.
8-1. Diagnostic Program
There are two kinds of folders for the operation check.
1. be300run
2. be300diag
These foldes exist in the Soft folder in the new CASIO Service Disc.
There is AutoRun.exe file in be300run folder.
There is Diag.exe file in be300diag folder.
You can perform the operation check only using CF (Compact Flash Memory) card installed these files.
The memory capacity of CF card for the operation check should be more than 2 Mbytes.
8-2. To enter into Operation Check
To enter into the operation check, at first, PC Connect software should be installed to PC using the bundled
CD-ROM. Refer to 7-2. PC Connect software in this manual. After installation of PC Connect, connect BE-
300 to PC using a cradle or USB cable (JK-582CA etc.). Boot PC Connect, and then connect BE-300 to PC
on software also.
To connect on software, refer to 7-2. PC Connect software in this manual also.
And confirm that BE-300 is connected to PC.
And then, install File Manager to BE-300 using the bundled CD-ROM.
It is easy to install File Manager. After clicking Software List in Top Menu with CD-ROM, select File Manager,
then follow the instructions that appear on the screen of PC. You can install File Manager to CF card also.
After this installation, confirm that File Manager exists in Top Menu on the screen display of BE-300.